THE FOLLOWING TABLE ADDRESSES THE INFORMATION
REQUIREMENTS OF REG.2015/1188
Item
Symbol Value
Unit
Heat output
Measured seasonal space heating energy efficiency
35%
Nominal heat output
P
nom
2.4
kW
Minimum heat output (indicative)
P
min
1.2
kW
Maximum continuous heat output
P
max
2.4
kW
Auxiliary electricity consumption
At nominal heat output
el
max
n/a
kW
At minimum heat output
el
min
n/a
kW
In standby mode
el
SB
0.001
kW
Type of heat input for electric storage local heaters only
Manual heat charge control with integrated thermostat
No
Manual heat charge control with room and/or outdoor temperature feedback
No
Electronic heat charge control with room and/or outdoor temperature
feedback
No
Fan assisted output
No
Type of heat output/room temperature control (select one)
Single stage heat output, no temperature control
No
With mechanical thermostat temp control
No
With electronic temperature control
Yes
Electronic temperature control with day timer
No
Electronic temperature control with week timer
No
Other control options (multiple selections possible)
Room temperature control with presence detection
No
Room temperature control with open window detection
Yes
Room temperature control with distance control option
No
Room temperature control with adaptive start control
No
Room temperature control with working time limitation
Yes
Room temperature control with black bulb sensor
Yes