![Clarke 6470612 Operation & Maintenance Instructions Manual Download Page 11](http://html.mh-extra.com/html/clarke/6470612/6470612_operation-and-maintenance-instructions-manual_2614603011.webp)
11
Parts & Service: 020 8988 7400 / E-mail: [email protected] or [email protected]
NOTE:
The pipe has an internal diameter of 13mm and is 100cm long.
NOTE: DO NOT
submerge the end of the pipe in water, as this may cause
water to be drawn back up into the machine.
TIMING AND ON/OFF FUNCTION
Setting the timer for both powering on and off will initiate the cycle timer
mode.
SETTING OF TIMER - POWER ON
1.
When the machine is powered off, press the “Timing” button.
2. The “Timing On” icon will flicker and the time set will flicker on the display
screen.
3. Press the “+” or “-” buttons to adjust the timing. The dehumidifier will make
a sound once the button is pressed. The time set will increase or decrease
by “1”, holding the button for 2 seconds will continually increase or
decrease the time.
4. Once the required time is set, non-action of the buttons for 10 seconds the
dehumidifier will accept the new setting and the “Timing On” icon will
flicker (Ranging from 0 to 24 hours, and 0 hours as default).
SETTING OF TIMER - POWER OFF
1.
When the machine is powered on, press the “Timing” button.
2. The “Timing Off” icon will flicker and the time set will flicker on the display
screen.
3. Press the “+” or “-” buttons to adjust the timing. The dehumidifier will make
a sound once the button is pressed. The time set will increase or decrease
by “1”, holding the button for 2 seconds will continually increase or
decrease the time.
4. Once the required time is set, non-action of the buttons for 10 seconds the
dehumidifier will accept the new setting and the “Timing Off” icon will
flicker (Ranging from 0 to 24 hours, and 0 hours as default).
HUMIDITY CONTROL
• When the rooms humidity value is 3% lower than the set humidity on the
machine, the compressor will shut down, the fan will delay shut down for
3 minutes and then shut down; and when it is 3% higher than the
humidity value set on the machine, both the fan and compressor will
start to operate.
• When the humidity is set at the minimum value (10%), the machines
default will enter the continuous dehumidifying mode.
Summary of Contents for 6470612