THE CHARGING PROCESS
STEP 1: ANALYSING 1
: Checks if the battery has connected with the charger.
STEP 2: DESULPHATION
: If battery voltage is too low, the program automatically
generates a pulsing current to remove sulphate.
STEP 3: SOFT START
: Charges with gradually increasing charging current.
STEP 4: CONTROLLED CURRENT CHARGE
: Adjusts the charging current intelligently.
STEP 5: ANALYSING 2
: Tests if the battery can absorb charge.
STEP 6: CONSTANT OUTPUT CHARGE
: Charges with constant voltage and
compensates for any fake full charge caused by high current charging.
STEP 7: RECOVERY CYCLE CHARGE
: Absorbs more charge and compensates for
the side effect of reduced charging current.
STEP 8: ABSORPTION
: Charges with constant trickle current for maximum battery
voltage.
STEP 9: ANALYSING 3
: Tests if the battery can hold charge.
STEP 10: MAINTENANCE
: Continuously monitors the battery, and charges with
trickle current once the voltage is lower than threshold.