background image

5

Parts & Service: 020 8988 7400 / E-mail: [email protected] or [email protected]

4.

Maintain power tools. Check for misalignment or binding of moving parts, 
breakage of parts and any other condition that may affect the power tool's 
operation. If damaged, have the power tool repaired before use.

 Many 

accidents are caused by poorly maintained power tools.

5.

Use the power tool, accessories and tool bits etc. in accordance with these 
instructions, taking into account the working conditions and the work to be 
performed. 

Use of the power tool for operations different from those 

intended could result in a hazardous situation.

6.

Have your power tool serviced by a qualified repair person using only 
identical replacement parts.

 This will ensure that the safety of the power 

tool is maintained

STAPLER SPECIFIC SAFETY WARNINGS

1. Always assume that the machine contains staples. Careless handling of the 

stapler can result in unexpected firing of nails and personal injury.

2. Do not point the stapler towards yourself or anyone nearby. Unexpected 

triggering will discharge the staples causing an injury.

3. Do not actuate the stapler unless it is placed firmly against the workpiece. 

If the tool is not in contact with the workpiece, the fastener may be 
deflected away from your target.

4. Disconnect the tool from the airline when the staples jam in the tool. While 

removing a jammed staple, the stapler may be accidentally activated if it 
is connected.

5. Do not use this stapler for fastening electrical cables. It is not designed for 

electric cable installation and may damage the insulation of electric 
cables thereby causing electric shock or fire hazards.

6. Never drive in staples at the edge of a work surface, as the edge could fail 

and fly off, endangering yourself or others in the vicinity.

7. Never fire tool at an angle. it must be perpendicular to the work surface

TRANSPORTATION

1. Never carry the tool by the air supply hose.

2. Never carry the tool with your finger on the trigger.

STORAGE

1. When not in use the tool must be disconnected from the air supply and 

stored in a dry place out of the reach of children.

2. Avoid storing the tool in environments where the temperature is below 0

o

Summary of Contents for 3110375

Page 1: ...OPERATION MAINTENANCE INSTRUCTIONS GC10 17 ISS2 ORIGINAL INSTRUCTIONS AIR STAPLER MODEL NO CSG1C PART NO 3110375 ...

Page 2: ... product Before attempting to use this product please read this manual thoroughly and follow the instructions carefully In doing so you will ensure the safety of yourself and that of others around you and you can look forward to your purchase giving you long and satisfactory service The Clarke CSG1 C is ideal for packaging carpet laying upholstery etc ...

Page 3: ... purchase This guarantee is invalid if the product is found to have been abused or tampered with in any way or not used for the purpose for which it was intended Faulty goods should be returned to their place of purchase no product can be returned to us without prior permission This guarantee does not effect your statutory rights Model Numbers CSG1 C Staple Sizes 22 gauge 4 16mm 9mm crown Magazine...

Page 4: ...ction used for appropriate conditions will reduce personal injuries 3 Do not overreach Keep proper footing and balance at all times This enables better control of the power tool in unexpected situations 4 Dress properly Do not wear loose clothing or jewellery Keep your hair clothing and gloves away from moving parts Loose clothes jewellery or long hair can be caught in moving parts POWER TOOL USE ...

Page 5: ...the stapler towards yourself or anyone nearby Unexpected triggering will discharge the staples causing an injury 3 Do not actuate the stapler unless it is placed firmly against the workpiece If the tool is not in contact with the workpiece the fastener may be deflected away from your target 4 Disconnect the tool from the airline when the staples jam in the tool While removing a jammed staple the s...

Page 6: ...ter is kept clean Line pressure or hose ID should be increased to compensate for unusually long air hoses over 10M Minimum hose dia should be 6mm 1 4 ID and fittings should have the same inside dimensions The air hose must be rated at least 150 of the maximum operating pressure of the tool A typical air line layout is shown above If an automatic in line filter regulator is used it will keep the to...

Page 7: ...air pressures It is recommended that air pressure be set to between 60 and 100psi at the tool when running The air inlet used for connecting air supply is a 10mm Quick Fit type If required connect an in line mini oiler to the tool A mini oiler helps to prolong the life of the air tool If a mini oiler is not being used run a few drops of oil through the tool before use It can be entered through the...

Page 8: ...apler is now ready for use OPERATION Turn on the air supply and check for air leaks If any are apparent rectify before proceeding Ensure the operating pressure is set to between 4 1 6 9bar 55 95 psi depending upon the size of nail used and type of material being worked The harder the material and bigger the nail the higher the pressure Hold the tool so that it is at right angles to the work Lower ...

Page 9: ...egardless of whether or not an air line lubricator is used 5 Use a clean dry cloth or brush to keep the stapler nailer clean and free of dirt Do not use solvent or alcohol based cleaners as they could damage the casing 6 The use of parts other than CLARKE replacement parts may result in safely hazards decreased tool performance and will invalidate your warranty DURING USE For lubricating the inter...

Page 10: ...ing out the air strainer and flushing out the tool with gum solvent or oil or failing this the motor may require dismantling Clarke Air Line Oil part no 3050825 is available from your CLARKE dealer SERVICE AND REPAIRS If the tool runs erratically or becomes inefficient although the air supply is in good order it may be necessary to dismantle the tool Such servicing and repair work should be carrie...

Page 11: ...11 Parts Service 020 8988 7400 E mail Parts clarkeinternational com or Service clarkeinternational com CONSUMABLES Staples 9mm Crown Type 71 Length Part No 8mm 1800400 10mm 1800402 12mm 1800403 ...

Page 12: ...12 Parts Service 020 8988 7400 E mail Parts clarkeinternational com or Service clarkeinternational com DECLARATION OF CONFORMITY ...

Page 13: ...13 Parts Service 020 8988 7400 E mail Parts clarkeinternational com or Service clarkeinternational com PARTS DIAGRAM ...

Page 14: ... 1 33 Fixed Magazine 8 Piston 34 Stop Plate 9 Collar 35 Bolt M4 x 6 10 O Ring 2 65 x 30 2 36 Spring Washer 4 11 Cylinder 37 Pusher 12 O Ring 2 65 x 18 38 Pusher Spring 13 Main Piston 39 Magazine Catch 14 Shock Absorber 40 Stepped Pin 15 Sealing Washer 41 Pin M2 x 10 16 Gun Body 42 Bolt M4 x 12 17 Washer 43 Movable Magazine 18 Rectangular Washer 44 Pusher 19 Trigger Valve Seat 45 Pulley 20 Trigger ...

Page 15: ..._____ __________________________________________________________________________ __________________________________________________________________________ __________________________________________________________________________ __________________________________________________________________________ __________________________________________________________________________ ___________________...

Page 16: ......

Reviews: