Clark-Reliance Reliance Simpliport 180 Installation, Operation & Maintenance Instructions Download Page 3

 

16633 Foltz Parkway 

 Strongsville, OH  44149 USA   Telephone: +1 (440) 572-1500   

  Fax: +1 (440) 238-8828 

www.clark-reliance.com  

  [email protected]

 
 
 

 

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 

 

    

 

 

OPERATION 

The Simpliport

®

 180 LED Illuminator can operate 

continuously.  The operating life of the LED’s is up to 
7 years under normal conditions. 

ROUTINE MAINTENANCE 

Keep the viewing receptors on the front viewing hood 
and the glass in the illuminator assembly clean using 
commercial glass cleaners, such as Windex

®

 or 

similar.  Never use harsh abrasives, wire brushes, 
metal scrapers, or any material that could scratch the 
viewing receptors or the glass. 

The Illuminator and viewing hood may be removed 
while in operation to inspect the Simpliport

®

 Gage. 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SPECIFICATIONS 

 
 Power Supply:   

115/230 VAC @ 50-60 Hz 

 Max Power 

 

  

 Consumption:   

500 mA 

 Est. Life: 

 

Up to 7 years (continuous) 

 Agency Approvals: 

FM/CFM Ordinary Locations

 

 

 

 

 Wire Size: 

 

Min 16 AWG - 14 AWG 

Consult factory for alternate size 
AWG size option 

 Max dist. from   

 

 power supply to light:  1000’ (305 M)  
 

 

Consult factory for different length 

Ambient Temperature:  -40F (-40C) to 170F (77C)

Viewing the Gage 

     

Figure 1 

Figure 2

                               Typical Installation 
 

Reviews: