2
CAUTION: Prior to starting step 6, verify
that the area is free of flammables.
6) Remove the cover on the power supply
once the power has been turned on. An
LED will be lit if it is wired correctly.
7) If the LED in the power supply is not lit,
check the power source and the
connection before continuing.
8) If the LED in the power supply is lit,
replace the cover on the power supply, and
connect the light ring to the power supply
using only the cable supplied.
9) If the cable will not reach the power
supply, contact your local representative
for the required extension cable.
OPERATION
Phaeton tank lights run continuously. The
operating life of the LED’s is 100,000 hours
under normal conditions.
Customers may install a switch or timer if
desired. Any additional components must be
installed prior to the customer’s sealing fitting.
ROUTINE MAINTENANCE
Keep window on the front of the light clean
using commercial glass cleaners, such as
Windex
®
or similar. Never use harsh abrasives,
wire brushes, metal scrapers, or any material that
could scratch the window. The window may be
cleaned while the unit is in operation.
The light may be removed while the unit is
in operation during inspection or maintenance of
the customer’s sight window or sight flow
indicator. The light ring may also be
disconnected from the power supply, if desired.
Disconnect the cord at the supplied screw
connector adjacent to the power supply. The
plant power going to the power supply does not
need to be disconnected.
Figure 1: Typical Phaeton Installation in Hazardous Environment
SPECIFICATIONS
Power Supply:
120 or 240 VAC @ 50-60 Hz
24V DC (600 mA)
Power
<1.0 Amp @120 VAC
Consumption:
<0.5 Amp @ 240 VAC
Est. Life:
100,000 Hours (continuous)
Agency Approvals:
FM and CSA
Ratings:
Class I, Div 1, Grps. B, C,
& D
Class II, Div 1, Grps. E, F, & G
Cenelec Rated to:
Eexd _________
Eexia, and IP 66 per IEC 529
Wire Size:
Min 18 AWG / Max 12 AWG
Max dist. from
90’ (27.5 M)
power supply to light:
Standard Cable = 8’ (2.5M)