background image

2

-

 

Loop start central office lines

-

 

PABX station numbers

-

 

Centrex numbers

Refer to Figure 1 for a block diagram of a typical PABX
installation.

Features

- Ring trip on first ring
- 600 ohm output; 8 ohm output with AGC
- Multiple units may be used for multi-zone paging with
all call behind a  PABX
- Music input
- Open loop detect
- Audio sensing circuit for reset
- Time out reset
- Manual reset
- Answer verification tone
- All call override tone
- Battery reversal indicator
- Auxiliary form C contacts
- Built-in connecting lock
- Powered by a receptacle mount power supply (included)

Limitations

When used with a PABX, the PABX must not return any
tones to the called party after calling party disconnect on
a station to station call.

Capacity

- Each STPA, when connected to its own PABX station
number, will provide one zone of paging.
- Use a STPA and a station number per zone for multi-
zone paging behind a PABX.
- An additional station number and STPA may be used to
provide all call or override in a one-way multi-zone
system behind a PABX.

Dimensions

-

 

8.25"H x 4.65"W x 2.25"D

       (20.96 cm x 11.81 cm x 5.72 cm)

-

 

1.5 lbs. (.68 Kg)

Nominal Specifications

Tip and Ring Input 

600 ohms

Voltage for Ring Trip

75-105VAC, 20 or 30Hz

Ring trip timing

150 ms

Open loop detect

150 ms starting 1 second

after ring trip

Audio sense release

4, 8, 16, 32, or 64

seconds after audio

drops below -22dbm

Time out release

4, 8, 16, 32, or 64 seconds

Manual reset

25 ms ground

Output 1:

Impedance

600 ohms

Page level

Output level = input level

-1 db

Music level

Output level = input level

Output 2:

Impedance

8 ohms

Page level

-10dbm

Music level

-17dbm

Music Source

8 to 600 ohm -10 to -18 dbm

Answer verification tone

500hz, 500 ms

All call override tone

500 hz, 250 ms on,

250 ms off

Form C Contacts

24 VDC, 3.0 amps or

105 VAC, 1.5 amps

Power Requirements

-21.5 to -26 VDC "B" Battery, 200 ma max. (power
supply included)

Environment

Temperature:  

0 to 50 Degrees C

Humidity:

0 to 85% non-precipitating

INSTALLATION

Instructions

Each instruction is preceded by a line.  Place a check on
the appropriate line as the instruction is completed.  The
instructions also include tests along the way to verify
connections have been made correctly.  If these steps are
followed properly, installation of the Clarity system will
go smoothly and quickly.  If the results of a test do not
correspond with what is shown, 

Do Not Proceed Until

the Problem has been Corrected.

ALL CALL IN

8 OHM OUT

ALL CALL AUDIO

T

IN

R

ZONE 1 IN

ALL CALL IN

8 OHM OUT

ALL CALL AUDIO

T

IN

R

ZONE 2 IN

ALL CALL OUT

8 OHM OUT

T

IN

R

ALL CALL IN

BLOCK DIAGRAM OF A TYPICAL PABX INSTALLATION

FIGURE 1

ONE-WAY
AMPLIFIED
SPEAKER
ASSEMBLIES

Summary of Contents for STPA

Page 1: ...ging PABX Station Level Paging NOTE Before proposing Station Level Paging for your PABX perform the following test 1 Dial between two stations on the PABX and answer the call 2 Have the called party listen after the calling party hangs up 3 After calling party release what does the called party hear If the PABX IMMEDIATELY returns any type of tones to the called party dial tone reorder tone etc th...

Page 2: ... 150 ms Open loop detect 150 ms starting 1 second after ring trip Audio sense release 4 8 16 32 or 64 seconds after audio drops below 22dbm Time out release 4 8 16 32 or 64 seconds Manual reset 25 ms ground Output 1 Impedance 600 ohms Page level Output level input level 1 db Music level Output level input level Output 2 Impedance 8 ohms Page level 10dbm Music level 17dbm Music Source 8 to 600 ohm ...

Page 3: ...__ 1 Unplug power supply __ 2 Reverse connections on pins 29 and 30 __ 3 Repeat step 4 __ 5 Unplug power supply Centrex C O and PABX Connecting Arrangements NOTE Place a check by the arrangement being used and proceed to the Figure indicated for step by step instructions __ 1 One Zone of One Way Paging Proceed to Figure 5 __ 2 Multi Zone One Way Paging with All Call Proceed to Figure 6 WIRING INST...

Page 4: ...Turn ON one of switches 3 7 to select the reset timing the length of time the unit stays active after last sensing audio Switch 8 must be ON If the STPA is being accessed from a Centrex or C O Line then set dipswitches 1 and 8 ON and switches 2 7 OFF 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 PABX Station Number Centrex Number or C O Line Music Source Optional...

Page 5: ... c Strap from pin 8 of the All Call STPA to pin 25 of each of the STPA s being used for individual zones __ d Strap from pin 9 of the all call STPA to pin 26 of each of the STPA s being used for individual zones __ e Strap from pin 13 of the all call STPA to pin 28 of each of the STPA s being used for individual zones FIGURE 6 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 30 29 28 27 26 25 24 23 22 21 20 19...

Page 6: ... 5 When the all call station number is dialed any paging in progress will be overridden and an alert tone will be returned to the overridden parties If they remain on the line on completion of the all call page they will be reconnected to their respective zones and all timers will be reset allowing a full page again on each zone TECHNICAL ASSISTANCE When trouble is reported verify that DC power is...

Page 7: ...REWAY OPENING TO WALL PLATE AND JUNCTION BOX WIRE TIE LOOP WIRE TIE USED TO BUNDLE WIRES ENTERING AND LEAVING TERMINAL AREA SNAP LATCH FOR COVER 155 DIA HOLES FOR MOUNTING TO SINGLE OR DOUBLE GANG JUNCTION BOX HOLE PATTERN MATCHES BOTH EURO AND US JUNCTION BOXES 1 5 x 2 WIRE ACCESS OPENING TO JUNCTION BOX BRACKET LOCKING SCREW FIGURE 7 ...

Page 8: ...tput pins 8 and 9 B Verify 24vdc to speakers GND is 24 vdc is A Refer to the appropriate connection Figure and verity dipswitches are set properly A Verify connection s according to Figure 6 B Verify all call out of master unit is connected to all call in of all other units C Verify 8 ohm output of master unit connected to all call audio in of all other units D Verify proper voltage and polarity o...

Reviews: