background image

1

CSP - STPA

Issue 3

  (540) 427-3505

STPA

TELEPHONE PAGE ADAPTER

INTRODUCTION

The STPA is a Telephone Page Adapter used to interface
Clarity mixer-amplifiers to Centrex lines, C. O. lines and
PABX stataion numbers.  This instruction contains the
specifications and guidelines necessary to install, operate,
and maintain the STPA which is manufactured by Clarity,
1111 Industry Avenue, Roanoke, VA  24013.

This paging unit has received FCC type KX registration.
 This Registration Number will be listed in the affidavits
filed with the telephone company; it will also be recorded
in the system log kept by installation and maintenance
personnel.  The local telephone company is to be notified
of the FCC Registration Number and Ringer Equivalence
Number.  FCC Registration Number:  BAF9I7-13957-
OT-N; Ringer Equivalence Number:  1.1A.  The STPA
connects to the telephone line by means of a standard jack
called the USOC RJ11C.

In accordance with FCC Rules with application tariffs,
the Page Adapter may only be installed with the
authorization of the owner of the host system.

DESIGN

General

The Clarity STPA Expandable Station Level Page
Adapter is designed to provide access to paging from a
standard PABX station number, a Centrex number, or a
Central Office line.  The unit is directly connected to
Clarity mixer-amplifiers.  Multiple Telephone Page
Adapters with mixer-amplifiers may be used to provide
multizone paging.

PABX Station Level Paging

NOTE:  Before proposing Station Level Paging for your
PABX perform the following test:
   1.  

Dial between two stations on the PABX and
answer the call.

   2.

Have the called party listen after the calling

party hangs up.

   3.

After calling party release, what does the called
party hear?

If the PABX IMMEDIATELY returns any type of tones
to the called party  (dial tone, reorder tone, etc.) then
STATION LEVEL PAGING CAN NOT BE USED. 
Consult your Clarity catalog for an appropriate trunk
level page adapter.  If there is a delay of at least 10
SECONDS before any tones are returned, then one-way
paging may be used but talkback paging will be
impossible.  If the line REMAINS SILENT after
disconnect, then one-way or talkback paging may be
used.

If the type of paging you desire is possible on a station
level of your PABX, then continue in this section to
determine the equipment required.
   1.

One Zone of One-Way Paging
This arrangement will require one PABX
station number, one STPA page adapter,
appropriate Clarity mixer-amplifier, and
speaker assemblies.

   2.

Multi-Zone One-Way Paging with All Call
This arrangement will require a PABX station
number and STPA for each zone, and an
additional number and STPA for All Call.

Centrex or C. O. Line Access to Paging

 

  1.

One Zone of One-Way Paging
One zone of one-way paging will require one
Centrex or C. O. Line, a STPA, and the
appropriate speakers.

   2.

Multi-Zone One-Way Paging with All Call
This arrangement will require a PABX station
number and STPA for each zone, and an
additional number and STPA for all call.

947421

SPECIFICATIONS

Applications

Summary of Contents for STPA

Page 1: ...ging PABX Station Level Paging NOTE Before proposing Station Level Paging for your PABX perform the following test 1 Dial between two stations on the PABX and answer the call 2 Have the called party listen after the calling party hangs up 3 After calling party release what does the called party hear If the PABX IMMEDIATELY returns any type of tones to the called party dial tone reorder tone etc th...

Page 2: ... 150 ms Open loop detect 150 ms starting 1 second after ring trip Audio sense release 4 8 16 32 or 64 seconds after audio drops below 22dbm Time out release 4 8 16 32 or 64 seconds Manual reset 25 ms ground Output 1 Impedance 600 ohms Page level Output level input level 1 db Music level Output level input level Output 2 Impedance 8 ohms Page level 10dbm Music level 17dbm Music Source 8 to 600 ohm ...

Page 3: ...__ 1 Unplug power supply __ 2 Reverse connections on pins 29 and 30 __ 3 Repeat step 4 __ 5 Unplug power supply Centrex C O and PABX Connecting Arrangements NOTE Place a check by the arrangement being used and proceed to the Figure indicated for step by step instructions __ 1 One Zone of One Way Paging Proceed to Figure 5 __ 2 Multi Zone One Way Paging with All Call Proceed to Figure 6 WIRING INST...

Page 4: ...Turn ON one of switches 3 7 to select the reset timing the length of time the unit stays active after last sensing audio Switch 8 must be ON If the STPA is being accessed from a Centrex or C O Line then set dipswitches 1 and 8 ON and switches 2 7 OFF 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 PABX Station Number Centrex Number or C O Line Music Source Optional...

Page 5: ... c Strap from pin 8 of the All Call STPA to pin 25 of each of the STPA s being used for individual zones __ d Strap from pin 9 of the all call STPA to pin 26 of each of the STPA s being used for individual zones __ e Strap from pin 13 of the all call STPA to pin 28 of each of the STPA s being used for individual zones FIGURE 6 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 30 29 28 27 26 25 24 23 22 21 20 19...

Page 6: ... 5 When the all call station number is dialed any paging in progress will be overridden and an alert tone will be returned to the overridden parties If they remain on the line on completion of the all call page they will be reconnected to their respective zones and all timers will be reset allowing a full page again on each zone TECHNICAL ASSISTANCE When trouble is reported verify that DC power is...

Page 7: ...REWAY OPENING TO WALL PLATE AND JUNCTION BOX WIRE TIE LOOP WIRE TIE USED TO BUNDLE WIRES ENTERING AND LEAVING TERMINAL AREA SNAP LATCH FOR COVER 155 DIA HOLES FOR MOUNTING TO SINGLE OR DOUBLE GANG JUNCTION BOX HOLE PATTERN MATCHES BOTH EURO AND US JUNCTION BOXES 1 5 x 2 WIRE ACCESS OPENING TO JUNCTION BOX BRACKET LOCKING SCREW FIGURE 7 ...

Page 8: ...tput pins 8 and 9 B Verify 24vdc to speakers GND is 24 vdc is A Refer to the appropriate connection Figure and verity dipswitches are set properly A Verify connection s according to Figure 6 B Verify all call out of master unit is connected to all call in of all other units C Verify 8 ohm output of master unit connected to all call audio in of all other units D Verify proper voltage and polarity o...