Clarity SMB-200 Quick Manual Download Page 2

2

SMB-200 2-CHANNEL POWER AMPLIFIER

5-CHANNEL MIXER

4-CHANNEL POWER-

 MIXER-AMPLIFIER

Booster

Output

FIGURE 1

Clarity

 Audio

Output

Environment

Temperature 

0 to 50°C

Humidity

0 to 85% non-precipitating

DESIGN

The SMB-200 100 Watt 2-Channel Amplifier is
designed to provide 100 watts of audio power in the
2-channel mode or 200 watts in the bridge mode. 

The SMB-200 amplifier can be used to operate 2
Ohm speaker loads in the 2-channel mode or  a 4
Ohm load in the 200 watt bridge mode.

The amplifier has  an input  volume control for each
channel located on the back of the unit. 

Circuit breakers are  provided on the back of these
units and will operate in the event of a catastrophic
overload.  The 2-channel amplifier contains limiting
circuits  for protection against short circuits or
impedance mismatches.  The units will shut down in
the event of a trouble condition and reactivate
automatically when the condition is corrected.

The amplifiers can be either shelf or rack mounted
(rack mount kit is optional).

INSTALLATION

General

Figure 2 shows volume control locations.  Figure 3
shows output terminal strips and switches on the back
of the amplifier as well as typical connections to a
mixer-amplifier.

Mounting

The SMB-200 is designed for shelf or rack mounting.
Make certain the unit is not mounted near heat
sources or strong magnetic fields.  Verify control and
terminal strip accessibility.  The unit may be rack
mounted.  Order the associated rack mount kit
SMA-RMK.

Input Connections

High impedance auxiliary devices such as mixers,
equalizers, mixing boards,  etc. can be connected to
channel A or B.   Phono jacks are provided at the rear
of the amplifier for each channel input.

Speaker Cabling

Standard two conductor speaker wire can be used
(14-20 AWG determined by the load).

Amplifier Setup

During initial system set up, it is recommended that
the channel A and B input gain controls be set 1/4
turn clockwise.

Summary of Contents for SMB-200

Page 1: ...nt optional rack kit SMA RMK Volume control for each channel ON OFF switch Circuit breaker protection Overload limiting circuit protection Phono jacks for input connections Screw terminals for output connections Power ON indicator per channel Clipping indicator per channel 2 ohm output 2 channel 4 ohm output bridge Dimensions and Weight 17 1 W x 14 75 D x 3 9 H 43 43 cm W x 37 38 cm D x 9 9 cm H 2...

Page 2: ...ble condition and reactivate automatically when the condition is corrected The amplifiers can be either shelf or rack mounted rack mount kit is optional INSTALLATION General Figure 2 shows volume control locations Figure 3 shows output terminal strips and switches on the back of the amplifier as well as typical connections to a mixer amplifier Mounting The SMB 200 is designed for shelf or rack mou...

Page 3: ...he unit These lights will illuminate when the output signal exceeds the power rating of the amplifier There are 2 power lights located on the front of the unit that will illuminate when the unit is connected to a 120 Vac power source and the power switch is in the ON position TECHNICAL ASSISTANCE When trouble is reported verify that AC power is being supplied to the unit and there are no shorts or...

Page 4: ...rranty are subject to a service charge The service charge will cover minor repairs major repairs will be subject to additional charges for parts and labor This warranty is in lieu of and excludes all other warranties expressed or implied and in no event shall Clarity be liable for any anticipated profits consequential damages loss of time or other losses incurred by the buyer in connection with th...

Reviews: