Remote Logic Sensor II Bypass
In case of extreme weather conditions such as high winds, the Logic Sensor II can be temporarily
bypassed from the Remote Transmitter while the system is armed to prevent the system from
false alarming.
To Bypass the Logic Sensor II:
1. With the system armed, press the Mode Button on the Remote Transmitter 3 times,
holding down on the third press.
2. Continue holding the Mode Button.
• After 5 seconds, the LED on the Remote Transmitter will begin to flash rapidly.
• The siren will chirp 3 times, indicating the Logic Sensor II has been bypassed.
3. Release the Mode Button.
•
The Logic Sensor II will remain bypassed until the next time the system is armed.
The system continuously monitors all protected zones, even when it is not armed, and warns you
if it detects a problem when you turn off the ignition.
1. Turn off the ignition.
2. If the siren chirps twice, the system has detected a problem.*
3. The status LED will flash to indicate the zone where the problem has been detected.
1 flash
=
door
2 flashes
=
Logic Sensor II
3 flashes
=
optional sensor
4 flashes
=
hood / trunk
* The system must see the zone open or active for at least 20 seconds before the zone is determined to be defective.
This way, opening the car door before turning off the ignition will not cause the siren to emit the warning chirps.
On Disarming, if the system responds with one long chirp, indicating the system was triggered,
the LED will flash for 60 seconds to indicate the zone that triggered the system. If the
Audible
Tamper Alert Report
feature is turned on during installation, the siren will chirp to indicate the
triggered zone.
LED Flashes (60 seconds):
1 flash
=
door
2 flashes
=
Logic Sensor II
3 flashes
=
optional sensor
4 flashes
=
trunk
example: flash-flash-pause-flash-flash-pause = Logic Sensor
Siren Chirps (once only)
1 chirp
=
door
2 chirps
=
Logic Sensor II
3 chirps
=
optional sensor
4 chirps
=
trunk
Full Time System Diagnostics
Tamper Alert
installation_MS5500.qxd 12/6/99 11:59 AM Page 21
Summary of Contents for UNGO MS5500
Page 1: ...installation_MS5500 qxd 12 6 99 11 59 AM Page 1 ...
Page 2: ...installation_MS5500 qxd 12 6 99 11 59 AM Page 2 ...
Page 4: ...installation_MS5500 qxd 12 6 99 11 59 AM Page 4 ...
Page 30: ...Page 26 MS5500 Installation Manual Notes installation_MS5500 qxd 12 6 99 11 59 AM Page 26 ...
Page 31: ...MS5500 Installation Manual Page 27 installation_MS5500 qxd 12 6 99 11 59 AM Page 27 ...