Doc ID - 904 • REV 06
3 / 4
3. Insert the threaded end though the hole, and then replace
the washer and locknut, tightening the locknut until the
connector is secure and does not wobble in the hole.
4. Screw the antenna to the connector until the antenna is
snug.
5. Attach the other end of the extender cable to the antenna
port on the rear of the CLIQ.express. See Figure 3, item 6.
Figure 5: Attaching the antenna with the extender cable
(1) SMA Male connector
(2) Washer
(3) Locknut
RS-232 port pinouts
If you are using your own RJ12 cable (rather than the one
supplied), ensure your RJ12 cable connector pinouts match
the pinouts on the RS232 port, as shown in Figure 6.
Figure 6: RS-232 port #1 with pinouts
Powering the CLIQ.express
Plugging in the power adapter automatically turns on the
CLIQ.express and starts the boot process.
To connect power to the CLIQ.express:
1. Plug the power adapter into a power receptacle on the
back of the CLIQ.express labeled “12vdc.” See
Figure 3, item 7.
2. Check the LED on the front of the CLIQ.express. It
illuminates when the device is receiving power. See
Figure 2, item 1.
Time, date, and time zone
Your CLIQ.express controller automatically detects and sets its
time, date, and time zone when you connect it to your data
network. CLIQ.express uses NTP and synchronizes the date
and time at boot up and periodically throughout the day.
Configure, test, and deploy a project
Refer to the Clare Controls Knowledge Base
instructions on creating, testing, and deploying a project. When
you deploy the project from Fusion, it will deploy to the
CLIQ.express.
Attaching a CLIQ.connect
When attaching a CLIQ.express to a CLIQ.connect, you must
attach the CLIQ.express over the CLIQ.connect.
Adding the rubber foot covers
To prevent the unit from sliding, use the four rubber foot covers
included with your CLIQ.express.
Peel each foot cover from the paper backing and place
one on each foot on the bottom of the CLIQ.express.
Specifications
I/O ports
USB 2.0
2
Ethernet LAN
1
RS232 [1]
1
CobraNet
1
General
Processor
Freescale iMX6
Operating system
Linux
Memory
2 GB DRAM, 1 GB NAND Flash
Power
8.4 W (700 mA at 12 VDC)
Operating temperature
41 to 113°F (5 to 45°C)
Relative humidity
10 to 90%, non-condensing
Dimensions (W × H × D) 1.3 × 8 × 6 in.
3.3 × 20.32 × 15.24 cm
[1] CLIQ.express supports RS232 speeds of 300 baud and higher.
(1) (3)
(2)
RS232
#1