Clare Controls CLIQ.express Installation Sheet Download Page 3

Doc ID - 904 • REV 06 

 

3 / 4 

3.  Insert the threaded end though the hole, and then replace 

the washer and locknut, tightening the locknut until the 

connector is secure and does not wobble in the hole.  

4.  Screw the antenna to the connector until the antenna is 

snug.  

5.  Attach the other end of the extender cable to the antenna 

port on the rear of the CLIQ.express. See Figure 3, item 6. 

Figure 5: Attaching the antenna with the extender cable 

 

(1)   SMA Male connector 

(2)   Washer 

(3)   Locknut 

 

RS-232 port pinouts 

If you are using your own RJ12 cable (rather than the one 

supplied), ensure your RJ12 cable connector pinouts match 

the pinouts on the RS232 port, as shown in Figure 6. 

Figure 6: RS-232 port #1 with pinouts 

 

 

Powering the CLIQ.express 

Plugging in the power adapter automatically turns on the 

CLIQ.express and starts the boot process.  

To connect power to the CLIQ.express: 

1.  Plug the power adapter into a power receptacle on the 

back of the CLIQ.express labeled “12vdc.” See  

Figure 3, item 7. 

2.  Check the LED on the front of the CLIQ.express. It 

illuminates when the device is receiving power. See 

Figure 2, item 1. 

Time, date, and time zone 

Your CLIQ.express controller automatically detects and sets its 

time, date, and time zone when you connect it to your data 

network. CLIQ.express uses NTP and synchronizes the date 

and time at boot up and periodically throughout the day. 

Configure, test, and deploy a project 

Refer to the Clare Controls Knowledge Base

 

Fusion Help

 for 

instructions on creating, testing, and deploying a project. When 

you deploy the project from Fusion, it will deploy to the 

CLIQ.express.  

Attaching a CLIQ.connect 

When attaching a CLIQ.express to a CLIQ.connect, you must 

attach the CLIQ.express over the CLIQ.connect. 

Adding the rubber foot covers 

To prevent the unit from sliding, use the four rubber foot covers 

included with your CLIQ.express.  

  Peel each foot cover from the paper backing and place 

one on each foot on the bottom of the CLIQ.express. 

Specifications 

 

I/O ports 

 

USB 2.0 

Ethernet LAN 

RS232 [1] 

CobraNet  

General 

 

Processor 

Freescale iMX6 

Operating system 

Linux 

Memory 

2 GB DRAM, 1 GB NAND Flash 

Power 

8.4 W (700 mA at 12 VDC) 

Operating temperature 

41 to 113°F (5 to 45°C) 

Relative humidity 

10 to 90%, non-condensing 

Dimensions (W × H × D)  1.3 × 8 × 6 in.  

3.3 × 20.32 × 15.24 cm 

[1] CLIQ.express supports RS232 speeds of 300 baud and higher. 

 