Clare Controls CLIQ.connect Installation Sheet Download Page 2

2 / 3 

 

Doc ID - 706 • REV 07 

Figure 1: Attaching CLIQ devices 

                                                                                                                                                                                                          

Adding the rubber foot covers 

If you are placing a CLIQ.connect on the bottom of a stack, use 

the four rubber foot covers included to prevent it from sliding.  

To add the rubber foot covers: 

  Peel each foot cover from the paper backing and place 

one on each foot on the bottom of the CLIQ.connect. 

Connecting devices to the CLIQ.connect 

Begin making connections to your other devices. Figures 2  

and 3 identify the LED and ports on the front and rear of the 

CLIQ.connect. Refer to the documentation that came with each 

of your other devices for detailed information about connecting 

them to the CLIQ.connect. 

To connect the CLIQ.connect: 

1.  Connect your serial devices to either of the two RS-232 

ports using a standard RJ12 cable, or an RJ12 to DB9 

cable (included). See Figure 3, item 1 and Figure 4. 

2.  Connect your IR devices (optional) to the 12-pin terminal 

connector (included), and then insert the connector into 

the port labeled “IR Outputs.” See Figure 3, item 2. 

Note:

 When connecting an IR emitter (included), attach 

the striped wire to positive (+) and the black wire to 

negative (-). 

3.  Connect your digital I/O devices (optional) to the 8-pin 

terminal connector (included), and then insert the 

connector into the port labeled “I/O.” See Figure 3, item 4. 
When connecting devices, wire it such that ports 1 and 2 

share the same12 VDC power and ground and ports 3 and 

4 share the same power and ground.  

4.  Connect relay contacts (e.g., garage door contacts) to the 

6-pin terminal connector (included), and then insert the 

connector into the port labeled “Relay.” See Figure 3, 

item 5. 

 

Figure 2: CLIQ.connect front  

                                                                                                                                                                                                          

(1)  LED – Illuminates blue when unit is powered on  

 

Figure 3: CLIQ.connect rear connections 

                                                                                                                                                                                                          

(1)  RS-232 (2 ports) 

(2)   IR Outputs 

(3)   ClareBus  

(4)   I/O 

(5)   Relay 

RS-232 port pinouts 

If you are using your own RJ12 cable (rather than the one 

supplied), ensure your RJ12 cable connector pinouts match 

the pinouts on the RS-232 ports shown in Figure 4. 

 

Figure 4: RS-232 ports with pinouts 

 

                                                                                                                                                                                                          

Configure, test, and deploy a project 

Refer to the 

Fusion Configuration Tool Administrator Guide

 

(Doc ID 069) for instructions on creating, testing, and deploying 

a project.  

RS232

IR Outputs

I/O

Relay

#1

#2

#1

#2

1 2 3 4 5 6

12

vd

c

G

nd

#3

 

#1

#2

12

vd

c

G

nd

#4

N

C

N

O

C N

C

N

O C

(1)

(2)

(3)

(4)

(5)

RS232

#1

#2

Reviews: