![Clare Controls ClareHome CS-iMR WOB Installation Sheet Download Page 3](http://html1.mh-extra.com/html/clare-controls/clarehome-cs-imr-wob/clarehome-cs-imr-wob_installation-sheet_2612457003.webp)
Doc ID - 1307 • REV 02
3 / 6
To connect power to the CS-iMR in the panel:
Caution:
Before attaching the power cord to the CS-iMR,
ensure the power switch is in the Off position.
1. Plug one end of the power cord into the power receptacle
at the top of the CS-iMR. See Figure 3, item 1.
2. Place the power cord on the left side, between the CS-iMR
and the panel’s sidewall.
3. Insert the 3-prong end of the North American power cord
through the bottom of the panel box (where the hole was
cut out), and then plug it into the electrical outlet. See
Figure 3, items 3 and 4.
4. Do not turn on power to the CS-iMR until you have made
all your device connections. See “Connecting devices to
the CS-iMR” on page 4.
Figure 3: Connect cords
(1) Power plug to receptacle
(2) CS-iMR
(3) 3-prong power plug
(4) Electrical box
Mounting the IMR in a Rack
When mounting the CS-iMR in a rack, you will need to order
and install a rack mount kit (P/N CS-IMR-RMK). Remove all
contents from the kit packaging and ensure that you have the
following items.
•
1 Left mounting bracket
•
1 Right mounting bracket
•
1 Front panel
•
2 Shims
•
12 6-32 × .5 in. black screws (2 extra screws included)
•
5 10-32 × .75 in. black rack mounting screws, 1 extra
screw included
To mount the CS-iMR in a rack:
1. Place the CS-iMR unit on a scratchproof surface, upside
down so that the text at the back of the unit is facing up.
2. Remove the three screws on each side of the iMR, (the
sides with venting and no connections), and discard those
screws. See Figure 4.
3. Remove the two screws from each side, approximately in
the center of the unit, and discard those screws.
4. Place the front panel bracket over the front of the CS-iMR
matching up screw holes on the sides.
5. Place the right and left ear brackets on each side of the
front panel bracket and align the holes with the holes on
the front panel and the CS-iMR.
6. Insert six 6-32 × .5 in. screws (three on each side) though
the holes and tighten. See Figure 4.
7. Place the shims between the ear brackets and the CS-iMR
(approximately in the center of the CS-iMR), and then
align the shims so that they line up evenly with the top of
the CS-iMR chassis.
8. Insert four 6-32 × .5 in. screws (two on each side) though
the holes in each ear bracket, shim, and CS-iMR, and then
tighten the screws. See Figure 4.
9. Flip over the assembly so that the top of the CS-iMR is
facing up, and then slide the assembly into the mounting
rack.
Note:
Be sure to leave at least 1U of spacing (1.75 in.
(4.45 cm)) above and below the CS-IMR when mounting it
in the rack.
10. Mount the assembly in the rack using four 10-32 × .75 in.
black rack mounting screws. See Figure 5.
(2)
(3)
(4)
(1)