Clare Controls ClareHome CS-iMR WOB Installation Sheet Download Page 3

Doc ID - 1307 • REV 02 

 

3 / 6 

To connect power to the CS-iMR in the panel: 

Caution: 

Before attaching the power cord to the CS-iMR, 

ensure the power switch is in the Off position.  

1.  Plug one end of the power cord into the power receptacle 

at the top of the CS-iMR. See Figure 3, item 1. 

2.  Place the power cord on the left side, between the CS-iMR 

and the panel’s sidewall.  

3.  Insert the 3-prong end of the North American power cord 

through the bottom of the panel box (where the hole was 

cut out), and then plug it into the electrical outlet. See 

Figure 3, items 3 and 4. 

4.  Do not turn on power to the CS-iMR until you have made 

all your device connections. See “Connecting devices to 

the CS-iMR” on page 4. 

Figure 3: Connect cords 

 

(1)  Power plug to receptacle 

(2)  CS-iMR  

 

(3)  3-prong power plug 

(4)  Electrical box   

 

Mounting the IMR in a Rack 

When mounting the CS-iMR in a rack, you will need to order 

and install a rack mount kit (P/N CS-IMR-RMK). Remove all 

contents from the kit packaging and ensure that you have the 

following items. 
• 

1 Left mounting bracket 

• 

1 Right mounting bracket 

• 

1 Front panel 

• 

2 Shims 

• 

12 6-32 × .5 in. black screws (2 extra screws included) 

• 

5 10-32 × .75 in. black rack mounting screws, 1 extra 

screw included 

To mount the CS-iMR in a rack: 

1.  Place the CS-iMR unit on a scratchproof surface, upside 

down so that the text at the back of the unit is facing up. 

2.  Remove the three screws on each side of the iMR, (the 

sides with venting and no connections), and discard those 

screws. See Figure 4. 

3.  Remove the two screws from each side, approximately in 

the center of the unit, and discard those screws. 

4.  Place the front panel bracket over the front of the CS-iMR 

matching up screw holes on the sides. 

5.  Place the right and left ear brackets on each side of the 

front panel bracket and align the holes with the holes on 

the front panel and the CS-iMR.   

6.  Insert six 6-32 × .5 in. screws (three on each side) though 

the holes and tighten. See Figure 4. 

7.  Place the shims between the ear brackets and the CS-iMR 

(approximately in the center of the CS-iMR), and then 

align the shims so that they line up evenly with the top of 

the CS-iMR chassis. 

8.  Insert four 6-32 × .5 in. screws (two on each side) though 

the holes in each ear bracket, shim, and CS-iMR, and then 

tighten the screws. See Figure 4. 

9.  Flip over the assembly so that the top of the CS-iMR is 

facing up, and then slide the assembly into the mounting 

rack. 

Note:

 Be sure to leave at least 1U of spacing (1.75 in. 

(4.45 cm)) above and below the CS-IMR when mounting it 

in the rack. 

10.  Mount the assembly in the rack using four 10-32 × .75 in. 

black rack mounting screws. See Figure 5. 

(2)

(3)

(4)

(1)

Reviews: