Hydrogen generator
Hydro200
21
The parts are available at CLAIND.
7.3.
Consumables list
The following table summarises the consumable parts available at
CLAIND.
In the purchase order, specify the
model
and
serial number
of the generator.
Consumables have to be substituted by the customer, because the substitution
is frequent and the operation is simple.
m
Never perform maintenance operations with the power supply con-
nected or with the generator switched on.
7.4.
Main fuse
The generator is protected by means of a fuse located in the electric power soc-
ket.
For replacement proceed as follows:
Component
part number
Maintenance operation
Operation frequency
710.07.2701
Drier replacement
every 20,000 litres of H2 pro-
duced
710.04.2123
Replace of Solenoid valve HDV/HVV
every 1 year
710.04.2122
Replace of Solenoid valve OVV
every 1 year
-
Cleaning fan
every 1 year
-
General overhaul
every 1 year
Description
PACK OF 1 DRIER RECHARGE FOR SERIES Hydro200
code number: 710.07.2701
• Remove the power cable from the soc-
ket
• Extract the fuse box
A
from the socket
• Replace the faulty fuse
• Refit the box and cable in the socket
• The generator can now be restarted.