background image

4

Installation instructions & user manual

 

9120-34373 v4.00 Nov 2018 - ZIP DBX DEX

Technical support 

 

Tel: 0345 6 005 005 email: [email protected]  www.zipwater.co.uk

SAFETY INSTRUCTIONS

To observe additionally for pressureless installation:

•  The water outlet behind the devices must not be blocked, and the water flow must not be 

restricted.

•  The water outlet facilities, such as shower heads must be decalcified regularly. Deposits 

must be removed at regular intervals.

•  Only the fittings recommended by the manufacturer may be used.
•  If the appliance is exclusively connected to a single shower, only the shower heads 

recommended by the manufacturer may be used. No other fittings or appliances which 

decrease the water flow to the shower may be installed.

•  The Zip InLine is intended for connection to mains supply only. In any other case please 

contact Zip on 0345 6 005 005 for advice.

•  Zip Water UK cannot be held liable for any damages caused by failure to observe 

these instructions.

!

 CAUTIONS

•  Optimum operation is ensured at a water flow pressure of 0.2 to 0.4 MPa (2-4 bar). The 

appliance must not be subjected to pressure exceeding 1.0 MPa (10 bar).

•  The appliance must only be used when correctly installed and in perfect working order.
•  The appliance must be installed in a frost-free room and must never be exposed to frost.
•  The DEX and DBX range is not intended for use with thermostatic mixing valves or 

taps. If thermostatic mixing valves or taps are to be used, their compatibility with the 

instantaneous water heater must be verified under site operating conditions.

•  The appliance must be completely filled with water before being switched on.
•  Before commissioning for the first time and each time the appliance or the piping system is 

emptied (e.g. due to work on the plumbing system or maintenance), the appliance must be 

purged by opening and closing the hot water tap until all air has been eliminated from the 

water heater and no more air emerges, before re-connecting to the electrical supply.

•  The appliance must only be used for heating wholesome (or cat 1) water. The specific 

water resistance must not fall below the required value indicated on the rating plate. The 

appliance must not be used for any other purpose.

•  Incoming water temperature must not exceed that stated in Technical data.

Summary of Contents for Zip InLine DBX Series

Page 1: ...0 34373 v4 00 Nov 2018 ZIP DBX DEX Technical support Tel 0345 6 005 005 email service zipindustries co uk www zipwater co uk Zip InLine Installation instructions user manual Modelnumber DBX DEX Electr...

Page 2: ...SAFETY INSTRUCTIONS 3 GENERAL PRODUCT DESCRIPTION 5 APPROVALS 5 DIMENSIONS 5 SPARE PARTS 6 TECHNICAL DATA 7 INSTALLATION 8 Requirements 8 Installing the wall bracket 9 Electrical connection 11 Electr...

Page 3: ...ngs and taps may be very hot when the appliance has been in use for some time The values stated on the rating plate must be observed In case of malfunction disconnect the mains power supply immediatel...

Page 4: ...re of 0 2 to 0 4MPa 2 4bar The appliance must not be subjected to pressure exceeding 1 0MPa 10bar The appliance must only be used when correctly installed and in perfect working order The appliance mu...

Page 5: ...ater heater for a decentralised water supply to one or more tap connections Its electronic control regulates the power consumption depending on the selected outlet temperature the respective inlet tem...

Page 6: ...specify the appliance model and serial number Spares are available however they may be on a made to order basis Fine filter IN82162 Flow limiter IN89108 DEX12 IN89110 DEX IN89109 DBX27 IN89110 DBX24...

Page 7: ...vity cm mS m 1300 77 1100 90 9 1300 77 Inlet temperature C 25 70 30 Flow rate to switch on max flow rate l min 2 5 5 0 3 2 5 8 0 3 2 5 7 0 3 2 5 8 0 3 2 5 9 0 3 Temperature rise at max flow C 25 33 32...

Page 8: ...be WRAS approved and of copper or steel construction Plastic pipes may only be used if they conform to EN 16893 Series2 The hot water pipes must be thermally insulated The specific resistance of the w...

Page 9: ...ld the mounting template provided on the wall and align it so that the holes in the template fit over the connections Mark the drill holes according to the template and drill them using a 6mm drill In...

Page 10: ...the wall bracket fits in the corresponding hole of the appliance If necessary slight corrections are possible by carefully bending the threaded rod of the wall bracket However it must be possible to s...

Page 11: ...sure cut out 4 Terminal strip 5 Safety thermal cut out 2 1 4 5 3 3 phase Single phase 2 1 4 5 3 Note Fasten the fittings with caution to avoid damage to the valves or the piping system For surface mou...

Page 12: ...itive load shedding relay Electrical connection from below 3 phase Single phase Note If necessary the connecting terminal can be moved to the upper part of the appliance To do so please follow the ins...

Page 13: ...st water Fit the grommet into the opening The protection grommet must be used Strip the cable roughly 6cm above the point where it emerges from the wall Support the appliance while the cable is routed...

Page 14: ...t registration card and return it to Zip or register the product at www zipwater co uk product registration Temperature Adjustment The factory set hot water outlet temperature is 50 C This factory set...

Page 15: ...Explain operation of the appliance to the end user and leave the operating instructions for their reference Complete the product registration card and return it to Zip or register the product on line...

Page 16: ...the appliance SERVICE MENU The service menu offers an overview of system parameters and is used for diagnostics Press key and key simultaneously for at least 2 seconds to call up the service menu the...

Page 17: ...yed value after pressing key refer to Trouble Shooting Diagnostics in the front cover By using the arrow keys and the last 10 error codes are displayed chronologically The display indicates in turn th...

Page 18: ...g agents or solvents For a good water supply the outlet fittings special tap aerators and shower heads should be unscrewed and cleaned at regular intervals Periodically the electrical and plumbing com...

Page 19: ...supply and take steps to prevents its inadvertent re connection Close the shut off valve in the mains water supply of the instantaneous water heater To open the cover take off the small fascia plate l...

Page 20: ...ct the preset temperature When pressing a programme key the preset temperature is selected and displayed The factory setting for programme is 35 C and for programme it is 48 C To assign settings for t...

Page 21: ...he display now counts backwards from 10 to 00 in second intervals The appliance is reset at value 00 Stop pressing the keys prior to this to cancel the process Reset 1 Press hold Reset completed 3 2 U...

Page 22: ...Service to reset STB Water stays cold digital display does light up DEX Safety thermal cut out tripped Contact Zip Service to reset STB Display flashes error message Er DEX Control system has switche...

Page 23: ...f the appliance or consequential damage to any other goods furnishings or property Zip does not exclude restrict or modify any liability that cannot be excluded restricted or modified or which cannot...

Page 24: ...ual 9120 34373 v4 00 Nov 2018 ZIP DBX DEX Technical support Tel 0345 6 005 005 email service zipindustries co uk www zipwater co uk ZipWaterUK 14BertieWardWay Dereham NorfolkNR191TE 03456005005sales z...

Reviews: