27
Have a bucket or similar container
at the ready to hold a quantity
of water that will be ejected
while the fi lter fl ush mode is in
operation. Open the fi lter access
door on the front of the HydroTap
and the fi lter cartridge will be
exposed. Located to the rear RHS
of the cartridge is a fl ush line,
approx 600 mm long and the fl ush
line stop cock. Hold the free end
of the fl ush line into the bucket or
container.
LCD Screen Operation - Section B
FILTER RESET
12:12 PM
External
filter
Internal
filter
This will reset the usage counters for the chosen item.
Select an item and press reset to confirm.
Life (months)
Life (litres)
12
000
Usage (days)
Usage (litres)
04000
000
INTERNAL FILTER LIFE
12:12 PM
Filter Reset
Select the internal/external fi lter
consumption and reset it by key-
stroke after each fi lter change.
Internal Filter Life
Enter the lifetime of the fi lter and
the current consumption (new
fi lter: 000).
If the consumption exceeds the
service life of the fi lter, fl ashing
Open the valve as shown in the
picture above and start the rinsing
process by tapping on the green
arrow.
The fl ushing process takes about
two minutes.
OPEN
CLOSE
After the rinsing process is com-
pleted, a message appears. Close
the valve, guide the fl ushing line
back into the fi lter compartment
and close the fi lter fl ap. Next,
reset the fi lter counter.
LEDs and the unit display indicate that the water fi lter must be
changed on some taps.
Standard service life of the internal water fi lter:
> Private households: 12 months or 4000 litres
> Commercial: 6 months or 6000 litres.
Filter Flush
Summary of Contents for Zip HydroTap G5 CS 100