36
This function should only be
considered when a Booster unit is
installed.
Note:
Failing to make the correct
selection for ‘Booster’ will eff ect
product performance.
LCD Screen Operation - Section B
Boiling calibration
The boiling point calibration is
started automatically during
initial commissioning and can be
repeated manually here. One run
takes approx. 10 minutes.
Note: Hot steam may escape from the fi tting during calibration!
Booster
CO2 SETTINGS
12:12 PM
CO2
Reset
CO2
Life
Purge
CO2
12:12 PM
PURGE WATER WITH CO2
INFO
This process removes water from the sparkling
chamber when a new CO2 bottle is installed.
This is an automatic process that will take 30 seconds.
III. CO
2
Settings
Every time the unit is put into
operation and after changing
the CO
2
cylinder, the carbonator
must be purged with CO
2
and the
counter reset.
CO
2
Purge
To start the function, tap the
green arrow. The fl ush runs for
approx. 30 seconds and ends
automatically.
CO
2
Reset
The consumption counter is reset
by selecting the circle and then
tapping the round arrow.
CO
2
Life
The CO
2
capacity can be set in
months or litres. A warning is
shown on the display as soon as
the CO
2
content reaches 20 %.
One 1.2 kg cylinder of CO
2
is enough for about 180 – 200 litres of
sparkling water.