23
CLAGE
EN
4. Installation
Tap
Spacer
Tray
Threaded
rod
S/S washer
Drain
Spider clamp
Fixing nut
Spacer
Washer
and fixing
nut
Optional: Installing the draining tray
The draining tray (article number: 4100-44111) is an accessory which can be used to
install the tap independently of a kitchen sink.
1. Ensure that a water supply, a drain, a socket fitted with at least a 10 A fuse
and enough room for the undersink unit are all available at the draining tray
installation location.
2. Place the template supplied over the tray installation location.
3. Cut out the holes as indicated on the template for an installation with a Classic,
Classic Plus, Touch Free or Arc tap.
Classic / Classic Plus / Touch-Free
a. Insert the draining tray. Place the plastic spacer between the worktop and the
tray at the 35 mm hole. Working from below, fasten the tray to the threaded rod
using the washer and fixing nut supplied.
b. Install the tap as described from point 3 onwards of “Installation Classic”.
c. If the drain bend is facing the wrong way, slacken off the fastening nut above
the bend, turn it to the correct position and then tighten up the fastening nut
again.
Arc
a. Insert the draining tray and fasten it to the threaded rods using the washers and
fixing nuts supplied.
b. Install the tap as described from point 3 onwards of “Installation Arc”.
4. Connect the drain bend to a siphon connecting sleeve, using a 22 mm diameter
hose. If no siphon connecting sleeve is available, use the snap connecting sleeve.
a. Place the snap connecting sleeve on the side of the siphon facing the sink. Drill a
13 mm diameter hole in the drain pipe behind the snap connecting sleeve for a
drain connection. Use a suitable sealant to make a watertight seal between the
snap connecting sleeve and the drain pipe.
Installing an external ion exchanger
An external ion exchanger should be used from 10 °dH to reduce limescale deposits in
the hot water tank of the appliance and thus extend the maintenance intervals.
Note: If installing an external ion exchanger, follow the instructions supplied for
the filter head and filter cartridge.
Note: to flush through the ion exchanger before using it for the first time, connect
it directly to the angle valve and drain the water into a bucket or drain (depend-
ing on the capacity: 2000 l = 1 min, 4000 = 2 min...).
1. Remove the bridge between the ‘BYPASS OUT’ and ‘BYPASS IN’ connections on the
undersink unit.
2. Connect the inlet on the filter head of the external filter to the ‘BYPASS OUT’
connection using a flexible hose with ⅜ inch union nuts.
3. Connect the outlet on the filter head of the external filter to the ‘BYPASS IN’
connection using a flexible hose with ⅜ inch union nuts.
Filter head article number: 84519
Filter cartridge (capacity at 10 °dH)
article number: 84500 = 4200 ltr
article number: 84501 = 8500 ltr
article number: 84502 = 20000 ltr
Tab
Threaded
rod
Drain
Washer
and fixing
nut
Arc
Classic