EN
26
1. Place the metal wall bracket in a central position above the water connection as per the ins-
tallation template. The metal wall bracket allows the appliance to be installed at a variable
distance from the wall (up to approx. 15 mm from the wall).
Fig. 5:
“Installing the metal wall bracket’ (dimensions in mm)
The heater is installed directly on the SMB or BGS special tap.
We guarantee trouble-free oper-
ation of the instantaneous water heater only if CLAGE fittings and accessories are used. Note
the following during installation:
• Installation must comply with DIN VDE 0100 and DIN 1988 or EN 806-2 and with the stat-
utory regulations of the country and the provisions of the local electricity and water supply
company.
• Check the technical data and information on the rating plate.
• Easy access to the instantaneous water heater must be guaranteed at all times for mainte-
nance purposes. An separate shut-off valve must be installed.
• Only use the appliance with an open-outlet tap.
• Ensure that all accessories are removed from the packaging.
• The water pipe must be securely embedded in the wall and it must be stable.
Installation
3.3 Installation instructions
3.4 Water connection
3.4.1 Water connection with SMB tap