CLAGE
27
EN
Lock level
The operating mode of the appliance can be restricted.
Activation of the Lock level:
1. Disconnect the appliance from the power supply (e.g. by switching off the fuses)
2. Insert the jumper on the power electronics (see picture)
3. Put the appliance into operation again
Deactivation of the Lock level:
1. Disconnect the appliance from the power supply (e.g. by switching off the fuses)
2. Remove jumper
3. Put the appliance into operation again
Reinstallation
In case the appliance will be commis sioned again under different installation condi-
tions than during its initial ope ration, it may be necessary to adapt the maximum
power rating. A temporary short-circuit of the two pins, e.g. with a screwdriver acc. to
EN 60900 (see figure), will reset all heater para meters to works setting and lock the
heating. Value “12“ flashes in the display until the maximum power rating has been
selected. This condition will maintain when activating and deactivating the supply
voltage.
8. Initial operation