From Flow Rate or Sensor Frequency screen, select
to access
menu.
Settings
X144D e-FlowMeter
Quick Start Programming
SETTINGS – VALVE (Adjust meter size and valve size parameters)
Note:
Stylus Pen Recommended for Touch Screen Programming
6” 100-01 v1.0
VALVE
YES
Select
then
to configure meter size
VALVE
YES
Size 1
Size 2
Size 3
Size 4
Select correct METER size from chart below
X144D Sizes
1
2
3
4
Full Port Valve Sizes
2
2-1/2
3
4
6
8
10
12
14
16
18
20
24
30
Reduced Port Valve Sizes
4
4
4
6
8
10
12
14
16
18
20
24 CF CF
YES
Save configuration
SETTINGS – OUTPUT (Adjust Gain, mA Scaling, mA Filtering, Pulse Weight, and 4-20mA Output Test)
OUTPUT
YES
Select
then
to configure output.
OUTPUT
YES
Set the Gain?
NEXT
1.00
Default Gain is 1.00. Use arrow keys to adjust gain to desired value. Increasing or decreasing
value offsets factory calibration. Select
to continue.
NEXT
Set the 20mA Value?
NEXT
002250.00
Use arrow keys to set 20mA Full Scale Output. Match 20mA value to customer display and/or
SCADA. Select
to continue.
NEXT
Set Filter Strength
NEXT
4.0
width
Default Filter is 4.00. Use arrow keys to increase or decrease filtering of 4-20mA signal. The
higher the average filter strength, the longer the averaging time. Select
to continue.
NEXT