Model 136-AU Dimensions
(In Inches)
Valve Size
(Inches)
2
2
1
⁄
2
3
4
A
Threaded
9.38
11.00
12.50
—
AA
150 ANSI
9.38
11.00
12.00
15.00
AAA
300 ANSI
10.00
11.62
13.25
15.62
B
Dia.
6.62
8.00
9.12
11.50
C
Max.
6.50
7.56
8.19
10.62
D
Threaded
4.75
5.50
6.25
—
DD
150 ANSI
4.75
5.50
6.00
7.50
DDD
300 ANSI
5.00
5.88
6.38
7.88
E
1.50
1.69
2.56
3.19
F
150 ANSI
3.00
3.50
3.75
4.50
FF
300 ANSI
3.25
3.75
4.13
5.00
G
Threaded
3.25
4.00
4.50
—
GG
150 ANSI
3.25
4.00
4.00
5.00
GGG
300 ANSI
3.50
4.31
4.38
5.31
H
NPT Body Tapping
3
⁄
8
1
⁄
2
1
⁄
2
3
⁄
4
J
NPT Cover Center Plug
1
⁄
2
1
⁄
2
1
⁄
2
3
⁄
4
K
NPT Cover Tapping
3
⁄
8
1
⁄
2
1
⁄
2
3
⁄
4
Valve Stem Internal
Thread UNF
10-32
10-32
1
⁄
4
-28
1
⁄
4
-28
Stem Travel
0.6
0.7
0.8
1.1
Approx. Ship Wt. Lbs.
35
50
70
140
X
Pilot System
13.00
14.00
15.00
17.00
Y
Pilot System
9.00
10.00
11.00
12.00
Z
Pilot System
9.00
10.00
11.00
12.00
Sizes:
Globe: 2" - 3" threaded 2" - 4" flanged
Angle: 2" - 3" threaded, 2" - 4" flanged
End details:
Flanged: 150 and 300 ANSI B 16.1
Threaded: 300 ANSI B 2.1
Temperature Range
Water: from 32°F to 140°F
Materials:
Main valve body and cover:
Ductile Iron ASTM A536
Epoxy coated inside and outside standard
Main valve trim:
Brass QQ-B-626
Bronze ASTM B-61
Optional: Stainless Steel 303
Stem: Stainless Steel 303
97VC-4 Programmable Controller
32 to 120 degrees Fahrenheit
Operating Pressure 7 to 150 psi
NEMA 6P waterproof
Single Lithium Battery, AA size, 3.6 volt
Pilot Control System:
Bronze and Copper
Optional: Stainless Steel
When Ordering, Please Specify
1. Catalog No. 136-AU
2. Valve Size
3. Pattern - Globe or Angle
4. Pressure Class
5. Threaded or Flanged Ends
6. Main Valve Materials Desired
7. Desired Pilot System Options
Specifications
PO Box 1325 Newport Beach CA 92659-0325
Phone: 949-722-4800
Fax: 949-548-5441
CLA-VAL
CLA-VAL CANADA
CLA-VAL EUROPE
4687 Christie Drive
Beamsville, Ontario
Canada LOR 1B4
Phone: 905-563-4963
Fax: 905-563-4040
Chemin dés Mesanges 1
CH-1032 Romanel/
Lausanne, Switzerland
Phone: 41-21-643-15-55
Fax: 41-21-643-15-50
©
COPYRIGHT CLA-VAL 2005 Printed in USA
Specifications subject to change without notice.
www.cla-val.com
E-136-AU
Represented By:
For 100-01 basic valves, suggested
flow calculations were based on flow
through Schedule 40 Pipe. Maximum
continuous flow is approx. 20 ft/sec
(6.1 meters/sec) & maximum intermit-
tent is approx. 25ft/sec (7.6
meters/sec).
Valve Selection
These Symbols
A
and
B
Indicate Available Sizes
Inches
2
2
1
⁄
2
3
4
mm
50
65
80
100
End Detail
Threaded
Threaded or Flanged
Model
136-AU
Basic Valve
100-01
Globe
A
A
A
A
Angle
B
B
B
B
Suggested Flow
(gpm)
Max. Continuous
210
300
460
800
Max. Intermittent
260
370
580
990
Suggested Flow
(Liters/Sec)
Max. Continuous
13
19
29
50
Max. Intermittent
16.4
23
37
62
100-01 (Globe)
B
100-01 (Angle)