background image

Model 136-AU Dimensions

(In Inches)

Valve Size 

(Inches)

2

1

2

3

4

A

Threaded

9.38

11.00

12.50

AA

150 ANSI

9.38

11.00

12.00

15.00

AAA

300 ANSI

10.00

11.62

13.25

15.62

Dia.

6.62

8.00

9.12

11.50

C

Max.

6.50

7.56

8.19

10.62

Threaded

4.75

5.50

6.25

DD 

150 ANSI

4.75

5.50

6.00

7.50

DDD 

300 ANSI

5.00

5.88

6.38

7.88

E

1.50

1.69

2.56

3.19

F

150 ANSI

3.00

3.50

3.75

4.50

FF

300 ANSI

3.25

3.75

4.13

5.00

G

Threaded

3.25

4.00

4.50

GG

150 ANSI

3.25

4.00

4.00

5.00

GGG

300 ANSI

3.50

4.31

4.38

5.31

H

NPT Body Tapping

3

8

1

2

1

2

3

4

J

NPT Cover Center Plug

1

2

1

2

1

2

3

4

K

NPT Cover Tapping

3

8

1

2

1

2

3

4

Valve Stem Internal
Thread UNF

10-32

10-32

1

4

-28

1

4

-28

Stem Travel

0.6

0.7

0.8

1.1

Approx. Ship Wt. Lbs.

35

50

70

140

Pilot System

13.00

14.00

15.00

17.00

Y

Pilot System

9.00

10.00

11.00

12.00

Pilot System

9.00

10.00

11.00

12.00

Sizes:

Globe:  2" - 3" threaded 2" - 4" flanged
Angle:  2" - 3" threaded, 2" - 4" flanged

End details: 

Flanged: 150 and 300 ANSI B 16.1
Threaded: 300 ANSI B 2.1

Temperature Range

Water: from 32°F to 140°F

Materials:

Main valve body and cover:
Ductile Iron ASTM A536

Epoxy coated inside and outside standard

Main valve trim:

Brass QQ-B-626
Bronze ASTM B-61
Optional: Stainless Steel 303
Stem: Stainless Steel 303 

97VC-4 Programmable Controller

32 to 120 degrees Fahrenheit
Operating Pressure 7 to 150 psi
NEMA 6P waterproof
Single Lithium Battery, AA size, 3.6 volt 

Pilot Control System:

Bronze and Copper

Optional: Stainless Steel

When Ordering, Please Specify

1. Catalog No. 136-AU 

2. Valve Size

3. Pattern - Globe or Angle

4. Pressure Class

5. Threaded or Flanged Ends

6. Main Valve Materials Desired

7. Desired Pilot System Options

Specifications

PO Box 1325 Newport Beach CA 92659-0325

Phone: 949-722-4800 

 

 Fax: 949-548-5441

CLA-VAL

CLA-VAL CANADA 

CLA-VAL EUROPE

4687 Christie Drive
Beamsville, Ontario
Canada LOR 1B4
Phone:     905-563-4963
Fax:         905-563-4040 

Chemin dés Mesanges 1
CH-1032 Romanel/
Lausanne, Switzerland
Phone:   41-21-643-15-55
Fax:       41-21-643-15-50

©

COPYRIGHT CLA-VAL 2005 Printed in USA

Specifications subject to change without notice.

www.cla-val.com

E-136-AU

Represented By:

For 100-01 basic valves, suggested
flow calculations were based on flow
through Schedule 40 Pipe. Maximum
continuous flow is approx. 20 ft/sec
(6.1 meters/sec) & maximum intermit-
tent is approx. 25ft/sec (7.6
meters/sec). 

Valve Selection

These Symbols

and 

Indicate Available Sizes

Inches

2

2

1

2

3

4

mm

50

65

80

100

End Detail

Threaded

Threaded or Flanged

Model

136-AU

Basic Valve

100-01

Globe

A

A

A

A

Angle

B

B

B

B

Suggested Flow

(gpm)

Max. Continuous

210

300

460

800

Max. Intermittent

260

370

580

990

Suggested Flow

(Liters/Sec)

Max. Continuous

13

19

29

50

Max. Intermittent

16.4

23

37

62

100-01 (Globe)

 

100-01 (Angle)

Reviews: