<Separate indicator> 

RUN display 

key 

MODE

MODE

RUN   OUT1   OUT2   

FS M  

CK D           m l/m i n

key


key

Used when entering various setting modes.

Used when advancing setting mode. 

Used when returning to flow rate display. 

Used when releasing peak hold operation.

Lighting

  :

Flashing

LED

Lights turned on when displaying flow rate.

Flash when peak hold operation.

OUTPUT display 

(OUT1,OUT2) 

Lights turned on when the output is turned ON.

Flash when overcurrent detected.

Flow  rate,  various  switches 

setpoints,  etc  or  status  are 

displayed. 

3-digit LED 

Data of CH1 is displayed in turn when displaying flow rate.

The  maximum  value  is  displayed  during  peak  hold 

operation. 

Determines the mode when selecting the mode. 

Used for count-up when setting each data.

Data of CH2 is displayed in turn when displaying flow rate.

The  maximum  value  is  displayed  during  peak  hold 

operation. 

Determine a mode when selecting the mode. 

Used for count-down when setting each data.

Switching mode

Note: 

1.Maintain  intervals  more  than  3%  F.S.  between  two  setpoints  during  window  operation. 
Hysteresis of 1% F.S. is provided on each ON and OFF sides automatically. 
2.Maintain intervals more than 1% F.S. between two setpoints when hysteresis operation. 
3.If the differential between above 2 setpoints is not satisfied, it may result in not operated 
or  unstable  operation.  If  a  switch  is  activated  in  unstable  flow  rate  state  such  as  a  fluid 
pulsation, etc.,  unstable  operation  may  be  provided.  In  this  case,  maintain  the  difference 
between  two  setpoints  satisfactorily,  use  the  product  after  checking  that  switching  is 
stabilized. 
4.In operation waveform, left side shows minus side, while, right shows plus side. 

5.If waveform pattern is decided, magnitude of ON and OFF setpoints is decided, and the 
reverse  magnitude  is  not  allowed.  However,  in  this  product,  operation  with  specified 
operation pattern has precedence over all things. When the two setpoints are inputted, the 
magnitude is identified automatically, processing the proper identification as ON and OFF 
setpoints. As result, even if ON and OFF setpoints are inputted reversely, re-recognized as 
correct ON and OFF setpoints, always operating with the specified operation pattern.

CH 

Waveform

ON setpoint

OFF setpoint

200 

350 

300 

250 

If  each  key  in  flow  rate  display  state  is 
pressed  down,  switch  data  ON  and  OFF 
setpoints, operation waveform, zero adjust 
value and models are displayed to check. 
Switching  is  not  affected  during  this 
operation. 

Data display 


Being held down


Operation waveform display      ON setpoint display

OFF setpoint display                        Operation waveform display

OFF side 

flash

ON side 

flash

Press simultaneously

Zero adjustment value/ 

Model No. display

Zero adjustment value display

ADJ display

Zero  point  adjustment  value  and  model 
number display are displayed alternately. 
Switching  is  not  affected  even  during 
operation.

Model No. display

Being held down

Maximum  and  minimum  values  indicated  with  flow rate  value  can  be  read  during the  specified period.  Use  this function when  checking 
instantaneous flow rate change. Also, peak hold operation never affects the basic function of this product such as switching and flow rate 
display, etc. 

Peak hold operation start 

(RUN light flash) 

Press simultaneously

MODE

Flow rate display 

condition [460] displayed.

Bottom value displayed


Bottom value [453]

Peak magnitude displayed

Flash

Peak magnitude [475]

Being held down

Flash

Being held down

Flash

Flash

Flash

Flash

Flash

1

Data return

1

2

1

MODE

Press simultaneously

Basic key operation 

Data setting of switch output function 

It is effective in the switching pattern setting/ ON/ OFF setpoint/ 0 adjustment mode. 

Count-

up 

Count-

down

Data reading

1

2

Switch CH1 

ON

/OFF data setting

MODE

Switch CH1 

Operation mode 

change. 

Channel 1 display

MODE

If key  operation is not done more than 2 seconds before confirming 
mode,  the  display  will  be  returned  to  flow  rate  display  for  safety.  If 
switching  off  during  operation  (state  of  each  setting  mode),  the 
display  will  be  returned  to  flow  rate  display  when  the  product  is 
switched on again. 

MODE

Being  held 
down 

If            key is further pushed, 

the  display  will  be  returned  to 
flow rate display

MODE

MODE

Separate 

ON point waveform 

display 

OFF point 

waveform display

Setpoint display

Alternate 

display

Operation mode 

display 

Setpoint display

Determination

An operation mode 

change by up/down key

Number change by 

up/ down key 

Switch CH2   

Operation mode change

0 point adjustment mode 

Switch output forcible ON mode 

CH1 output ON

CH2 output ON

Adjusted value 

reading 

1

Being held down

2

Being held down

MODE

1

2

MODE

MODE

Switch CH2 

ON/OFF data setting

Set same as a switch 

CH1. 

[ADJ] display 

0 point adjustment value display

MODE

MODE

MODE

MODE

1

1

Press once

To flow rate display

Determination

Press simultaneously

Press simultaneously

Determination

Press once

Press once

Press once

Press once

Press once

Press once

Press once

Press once

Press once

Press once

To flow rate display

To flow rate display

Press once

Alternate 

display

Alternate 

display

Alternate 

display

Caution    Adjust 0 point in the state that a fluid never flows.

MODE

Press once

Switch function

Setpoint verification method

Name and functions of display/controls

Peak hold function

Switch output function/forcible output function/0 point adjustment operation

Set example

O per ation patt ern nam e

and  LE D  display 

Oper ation wavef orm

W indow  oper ation  1 

( Range  inside  ON) 

W indow  oper ation  2 

( Range  out O N)  

Hyst eresis operation  1

(Flow r at e sm all side 

ON) 

Hyst eresis operation  2

(Flow r at e lar ge  side 

ON) 

S wit ch output  OFF

ON

OFF

1%F.S.    3%F.S. or more

1%F.S.

ON

OFF

The output is turned off not depending 

on ON and OFF setpoint.

ON

OFF

1%F.S. or more 

0 OFF setpoint ON setpoint   flow rate

ON

OFF

3%F.S. or more

0 ON setpoint OFF setpoint   flow rate

0 OFF setpoint ON setpoint   flow rate

0 ON setpoint OFF setpoint   flow rate 

1%F.S.    3%F.S. or more

1%F.S.

ON

OFF

flow rate