18
Allowed Allowed d RDM
X
DISC_UNIQUE_BRANCH 0x0001
X
DISC_MUTE 0x0002
X
DISC_UN_MUTE 0x0003
X X
PROXIED_DEVICES 0x0010
X X
PROXIED_DEVICE_COUNT 0x0011
X X
QUEUED_MESSAGE 0x0020
X X
SUPPORTED_PARAMETERS 0x0050
X X
PARAMETER_DESCRIPTION 0x0051
X X
DEVICE_INFO
0x0060
Reports Category 0x0801
X X
PRODUCT_DETAIL_ID_LIST
0x0070
Repots ID 0x0604
X X
DEVICE_MODEL_DESCRIPTION 0x0080
X X
MANUFACTURE_LABEL
0x0081
City Theatrical, Inc.
X X X
DEVICE_LABEL 0x0082
X X X
FACTORY_DEFAULTS 0x0090
X X
SOFTWARE_VERSION_LABEL 0x00C0
Reports
CE/FCC
X X
DMX_PERSONALITY
0x00E0
Sets Limited Burst
X
DMX_PERSONALITY_DESCRIPTIO
N
0x00E1
X X
DMX_START_ADDRESS 0x00F0
X X
SENSOR_DEFINITION 0x0200
RSSI,
Temp
X X
SENSOR_VALUE 0x0201
X X X
IDENTIFY_DEVICE 0x1000
X X X
RDM_TRAFFIC_ENABLE 0x7FE2
Draft
X X
SHOW_ID 0x8000
X X
OUTPUT_POWER 0x8001
X X
HOP_PATTERN 0x8002
X X
BANDWIDTH 0x8003
X X
LATENCY 0x8019
X X X
DMX_RDM_ INTERLEAVE_RATIO
0x801B
X X X
PROXIED_DEVICES_ENHANCED 0x801C
X X
ADAPTIVE_ON_OFF 0x801D
In order to allow RDM traffic and discovery and control of connected Responders you must
enable RDM Traffic (Set RDM_TRAFFIC_ENABLE to 01).
Note that DMX transmission fidelity may be slightly reduced when RDM Traffic is enabled.
To learn more about RDM, a good place to start is the Wikipedia article on RDM (lighting) at:
http://en.wikipedia.org/wiki/RDM_(lighting)