Z-2M & Z-2MR Installation Manual 

Includes Zone Remote Installation 

 
 

Z-2M   

 Dual Zone Mixer      

 

Code 953.003 

Z-2MR 

 Dual Zone Mixer & Remotes  

Code 953.009 

Summary of Contents for Z-2M

Page 1: ... 1 Z 2M Z 2MR Installation Manual Includes Zone Remote Installation Z 2M Dual Zone Mixer Code 953 003 Z 2MR Dual Zone Mixer Remotes Code 953 009 ...

Page 2: ...er inputs are switched off All of these inputs have their own gain control mounted on the rear panel Both of the output zones are balanced stereo low impedance There is also a mono selector switch for each of these outputs The rear panel is completed by provision for the connection of expansion modules to increase the number of zones up to six access for the remote control option and an IEC AC pow...

Page 3: ... 3 ...

Page 4: ...he inputs and outputs are properly made Always use good quality connectors such as Neutrik it s a small investment that can save your time and money Connecting Up 8 Microphone Input The microphone input is balanced If you wish to use an unbalanced microphone short pin 3 to pin 1 ground and connect the signal input pin 2 This microphone has first priority in the system and will override the music s...

Page 5: ...on As per Zone 1 mono button 23 AC Power Socket A standard IEC AC power socket for connecting to the main AC supply Use only the AC mains power lead supplied with the unit and check that the supply voltage matches the rating uppermost on the fuse mounted on the socket This unit is designed to operate at 220 or 230V Europe Asia Installer Settings The Z 2M Z 2MR have features which are set up by the...

Page 6: ... part code 953 006 1 Zone 1 or2 Input Selector Switch In position Off as illustrated all the music inputs are defeated the possible exception is the priority input which is explained below In position Line 1 2 or 3 the zone output will carry the selected source The inputs can be labelled using the label set provided with this manual 2 Music Priority Inputs This switch selects the music source conn...

Page 7: ...king sure that Pin 1 of the ribbon lines up with Pin 1 on the PCB Ideally the ribbon connection should be undertaken once the remote cable connections have been made this allows the maximum working area Once the ribbon has been connected the cover of the unit can be replaced The recommended cable for remote control is 8 core shielded alarm cable 804 299 The terminals on the module are colour coded...

Page 8: ...een it and the front panel Notice the terminal connections are colour coded on the back of the PCB to match those at the other end of the cable Make the connections to the terminal strip and replace it into the retaining pegs on the PCB Make sure it is pushed home firmly Peal back the braiding on the cable and ensure it is secured by the P clip clamp holding the cable to the PCB Notice the P clip ...

Page 9: ... Burst Transient Immunity iv EN61000 3 2 Mains Harmonic Disturbance Limits Generic Std EN50081 1 v EN55022 Class B Conducted Mains RF Emission Limits Generic Std EN50081 1 Electrical Equipment Safety Regulations 1994 The Z 2M Z 2MR have been designed and tested to demonstrate compliance to the LVD 73 23 EEC directive using the following standard i EN60065 Safety requirements for mains operated ele...

Page 10: ... 10 Block Diagram ...

Page 11: ...xpansion unit for the Z 2M and Z 2MR The mic music input alarm override signals and power supply rails are liked from the zone mixer Z 2M or Z 2MR via a 2 way IDC ribbon socket Giving you an extra two zones Z 4X Zone Expansion Module 953 015 The Z 4X is a quick and est to install expansion unit for the Z 2M and Z 2MR The mic music input alarm override signals and power supply rails are liked from ...

Page 12: ... 12 For other Citronic products in the range visit www citronic com ...