 Warning

PLEASE READ THIS MANUAL BEFORE ANY ATTEMPT 
TO USE THIS PRODUCT IS MADE.

PRECAUTIONS

The ear thermometer must be inserted correctly to obtain 
correct temperature measurement.
Be sure to consult a physician if you feel that your health 
is in poor condition.
DO NOT judge your health only on the presence or 
absence of a fever.

1.  Make sure that the probe lens is always clean.

KEEP PROBE LENS CLEAN

GOOD

NOT GOOD

2.  Very carefully and gently insert the probe into the ear.
3.  Avoid using the ear thermometer if there is infl ammation 

on or in the ear.

4.  DO NOT use the ear thermometer if the main body is 

damaged (for example, the probe lens is broken). The 
continuous use of a damaged unit may cause injury, 
improper results, or serious danger. Contact a physician 
immediately if broken pieces are swallowed.

Protect the natural environment:

Please help protect natural environment by respecting 
national and/or local recycling regulations when disposing of 
the battery and the product at the end of their useful live.

WEEE

If you dispose this product, do not dispose of 
with general household waste. There are separate 
collection systems for used electronics products 
in accordance with legislation under the WEEE 
Directive (Directive 2002/96/EC), effective only 
within European Union.

Summary of Contents for CT830

Page 1: ...INSTRUCTION MANUAL for DIGITAL EAR THERMOMETER REF CT830 Probe Probe Cap ON MEM button LCD SCAN button Probe lens IDENTIFICATION OF PARTS Fig 1 English 0801...

Page 2: ...on on or in the ear 4 DO NOT use the ear thermometer if the main body is damaged for example the probe lens is broken The continuous use of a damaged unit may cause injury improper results or serious...

Page 3: ...and do NOT allow the unit to come into contact with chemical solvents 4 Do NOT drop the ear thermometer and do NOT expose the ear thermometer to heavy shock The ear thermometer is not shock protected...

Page 4: ...erature so you can compare it to the measurement result About Ear Thermometers All objects radiate heat To measure body temperature this ear thermometer uses an infrared sensor incorporated in its pro...

Page 5: ...n for about 5 sec and the icon starts to ash indicating the setting mode Fig 5 Fig 5 Date Time 24 12 hour display 2 Press the SCAN button for the 12 24 hour setting mode The icon starts to ash indicat...

Page 6: ...emove the probe and read the temperature on the display Fig 8 Fig 8 Ear temperature mark NOTE The time and calendar settings should be done before measurement readings are taken The thermometer always...

Page 7: ...the MATERIAL SURFACE TEMPERATURE scan mode with icon Fig 10 Fig 10 Material surface temperature mark 3 1 Aim the probe torward the material and press the SCAN button and the material surface temperatu...

Page 8: ...eps to warn the user of a fever MEMORY There are a total of 9 memory slots for recording EAR TEMPERATURE measurements Each memory slot also records the date and time of the measurement Memory slots ca...

Page 9: ...NG on the display except the time and date When the ON MEM button is pressed NOTHING is displayed except the battery mark blinking 12 times followed by OFF for 1 second and then the display returns to...

Page 10: ...oo long may cause the probe to make a higher ambient temperature reading This could make the body temperature measurement lower than usual After each use clean the probe and probe lens with a cotton s...

Page 11: ...sert it If the message reappears contact the retailer where you purchased the thermometer for service 1 Ear temperature mode Temperature taken is higher than 42 2 C 108 F 2 Material surface temperatur...

Page 12: ...Q4 Is it hygienically safe to use the ear thermometer without the probe cover A4 The probe and probe lens should be kept clean by using a cotton swab or soft cloth moistened with 70 alcohol Therefore...

Page 13: ...ent Operating temperature range 10 40 C 50 104 F Storage temperature range 20 50 C 4 122 F Transportation temperature range must be less than 70 C Unit size 115 L X 37 W X 29 H mm Weight Approx 60g in...

Page 14: ...Prob Prob IDE Design and Specification are subject to change without notice CITIZEN is a registered trademark of Citizen Holdings Co Japan CITIZEN es una marca registrada de Citizen Holdings Co Jap n...

Reviews: