Support
model
CT-S280
CT-S300
CT-S2000
CT-S4000
CT-S251
CT-D150/E351
CT-S281
CT-S310
CT-S801/851
CT-S601/651
CT-P29x series
CT-S310II
CT-D151/E651
- 208 -
fn=3: Function 3 Setting Memory Switch Value
GS ( E pL pH fn [a1 b18...b11] ... [ak bk8...bk1]
[Code]
<1D>H<28>H<45>H<pL><pH><fn> [<a1><b18>…<b11>] … [<ak><bk8>…<bk1>]
[Range]
10
≤(pL+pH×256)≤65535
fn=3
b=48, 49, 50
CT-S280
a=1, 2, 3
CT-S300
a=1, 2, 3, 4
CT-S281
a = 1, 2, 3, 4, 5, 13
CT-S310
/
CT-S2000
/
CT-S4000
/
CT-P29x series
a = 1, 2, 3, 4, 5
CT-S801(II)
/
CT-S851(II)
/
CT-S601(II)
/
CT-S651(II)
/
CT-S310II
/
CT-S251
/
CT-D150
/
CT-E351
/
CT-D1
51
/
CT-E651
a=1, 2, 3, 4, 5, 6
[Outline]
[The specification which is common to the model]
• Changes the MSW set in a to the value set in “b”.
B
Function
48
Sets corresponding bit to OFF.
49
Sets corresponding bit to ON.
50
Does not change corresponding bit.
[Caution]
[The specification which depend on the model]
CT-S281
/
CT-S310
/
CT-S2000
/
CT-S4000
/
CT-P29x series
/
CT-S801
/
CT-S851
/
CT-S601
/
CT-S601
/
CT-S310II
/
CT-D150
/
CT-E351
• MSW7 to MSW10 cannot be changed by this command. They can be changed by the
setting of customize value.
CT-S801II
/
CT-S851II
/
CT-S601II
/
CT-S651II
/
CT-D151
/
CT-E651
• MSW7 to MSW10,13 cannot be changed by this command. They can be changed by the
setting of customize value.
CT-S251
• MSW7 to MSW10,11,13 cannot be changed by this command. They can be changed by
the setting of customize value.