fn=1: Function 1 Transferring to Printer Function Setting Mode
GS ( E pL pH fn d1 d2
[Code]
<1D>H<28>H<45>H <pL><pH><fn><d1><d2>
[Range]
(pL+pH×256)=3 (pL=3, pH=0)
fn=1
d1=73 (“I”)
d2=78 (“N”)
[Outline]
[The specification which is common to the model]
• Transfers to printer function setting mode and sends the report of mode transfer.
Hex.
No. of Data
Header
37H
1
ID
20H
1
NULL
00H
1
fn=2: Function 2 End of Printer Function Setting Mode
GS ( E pL pH fn d1 d2 d3
[Code]
<1D>H<28>H<45>H <pL><pH><fn><d1><d2><d3>
[Range]
(pL+pH×256)=4 (pL=4, pH=0)
fn=2
d1=79 (“O”)
d2=85 (“U”)
d3=84 (“T”)
[Outline]
[The specification which is common to the model]
• Terminates printer function setting mode and executes resetting.
• Clears input buffer and print buffer and restores various kinds of setting to the state at power on.