2.2.8 Paper Detecting Commands
ESC c 3 n
[Function]
Selecting the Paper Sensor valid for a Paper-end signal output
[Code]
<1B>H<63>H<33>H<n>
[Range]
0
≤n≤255
[Outline]
[The specification which is common to the model]
• This command selects by which Paper Sensor a Paper-end signal should be output. Each bit for “n” has the
following meaning:
Bit
Position
Value
0
1
0
Paper Near-end
Disabled
Enabled
1
Paper Near-end
Disabled
Enabled
2
Paper-end
Disabled
Enabled
3
Paper-end
Disabled
Enabled
4
Undefined
—
—
5
Undefined
—
—
6
Undefined
—
—
7
Undefined
—
—
[Caution]
[The specification which is common to the model]
• This command is valid only for the parallel interface.
[Default]
[The specification which depend on the model]
CT-S280
/
CT-S281
/
CT-S300
/
CT-S310
/
CT-S2000
/
CT-S4000
n=15
CT-P29x series
/
CT-S301II
/
CT-D150
/
CT-E351
n=15 (no signal at paper near end due to no paper near end sensor.)
CT-S801(II)
/
CT-S851(II)
/
CT-S601(II)
/
CT-S651(II)
/
CT-S251
/
CT-D151
/
CT-E651
• MSW3-2 OFF: n=15
• MSW3-2 ON : n=12