Citizen CHU503 Instruction Manual Download Page 6

- Eng 9 -

English

Español

Português

Français

Py

сский

中文

한국어

- Eng 10 -

한국어

中文

Py

сский

Français

Português

Español

English

REMOVING THE BATTERIES

•  When the icon 

 is displayed or nothing appears in the display, replace the old 

batteries with four new ones. All four batteries should be changed at once.

 

: The remaining capacity of the batteries is inadequate.

•  Adjust the clock after changing the batteries.
•  The data stored in the memory is not deleted by changing the batteries.
•  Do not use rechargeable batteries.
•  Do not use alkaline (LR6) and manganese (R6P) batteries together.
•  Batteries included are for demonstration purposes only. Battery life may be 

shorter than speci

fi

 ed.

•  When disposing of used batteries, comply with governmental regulations or 

environmental public institution’s rules that apply in your country/area.

2

   Plug the AC adapter into a mains power outlet.

•  If you plan to use the AC adapter for an extended period of time, remove the 

batteries. If the batteries are left in the compartment, electrolyte may leak from the 
batteries and cause a fault in the blood pressure monitor.

•  It is recommended that batteries are in the unit when using the AC adapter. If 

there are no batteries in the unit when the AC adapter is disconnected from either 
the power outlet or the unit itself, date and time settings will be lost.

•  Plug the AC adapter into the socket, where you can easily plug off soon and 

safely in times of trouble.

•  When disconnecting the AC adapter, unplug the AC adapter from the main 

power outlet, and then unplug the AC adapter plug from the socket on the blood 
pressure monitor.

1

  Insert the AC adapter plug into the socket on the blood pressure 

monitor.

AC adapter 
socket

The dedicated AC adapter (model:AC-230CZ) for the CHU503 is optional. 

The AC adapter is available from retailers stocking CITIZEN digital blood pressure monitors.

Using the optional dedicated AC adapter (model:AC-230CZ) for the CITIZEN blood 
pressure monitor (CHU503) allows you to measure your blood pressure without 
having to worry about the amount of remaining charge in the batteries.

Warning

The 

CHU503

 and AC-230CZ should be used indoors in dry 

location.

USING AC ADAPTER (OPTION)

AC adapter 
plug

AC adapter 

mains power 
outlet

*  Make sure there is no 

obstruction within the 
immediate vicinity of 
the AC adapter so that 
it can be immediately 
unplugged from the 
mains power outlet.

TIME ADJUSTMENT

Setting the clock enables measurements to be accurately recorded.

The monitor can record the date and time of measurement as well as the 
measurement results. Be sure to set the clock after inserting the batteries. Set the 
date 

fi

 rst and then the time.

*  When you install the batteries for the 

fi

 rst time, the monitor will display the 

clock setting screen. You do not need to perform step 1. Proceed to step 2. 
If you set the clock and change its setting, start from step 1.

1

  Press and hold the 

 Date/Time Set switch for 

approximately two seconds.

 

The “year” indicator blinks.

2

 Press 

the 

 

Adjust switch to adjust the 

year

.

 Press 

 Adjust switch to increase the number by one. 

(The year can be adjusted in the range of 2013-2042.)

 Press 

 Date/Time Set switch to confi rm the setting. 

 

The “year” is set and the “month” indicator blinks.

 * 

 

 

You can fast-forward the numbers in display by 
pressing and holding 

 Adjust switch.

3

 Press 

the 

 

Adjust switch to adjust the “month”.

 

Press 

 Adjust switch to increase the number by one.

 Press 

 Date/Time Set switch to confi rm the setting. 

 

The “month” is set and the “day” indicator blinks.

4

 Press 

the 

 

Adjust switch to adjust the “day”.

 

Press 

 Adjust switch to increase the number by one.

 Press 

 Date/Time Set switch to confi rm the setting.

 

The “day” is set and the “hour” indicator blinks.

5

 Press 

the 

 

Adjust switch to adjust the “hour”.

 Press 

 Adjust switch to increase the number by one.

 Press 

 Date/Time Set switch to confi rm the setting.

 

The “hour” is set and the “minutes” indicator blinks.

6

 Press 

the 

 

Adjust switch to adjust the 

“minutes”.

 Press 

 Adjust switch to increase the number by one.

 Press 

 Date/Time Set switch to confi rm the setting.

 

The “minutes” are set and “12” (12-hour format) blinks.

Summary of Contents for CHU503

Page 1: ...Py Fran ais Portugu s Espa ol English INSTRUCTION MANUAL FOR DIGITAL BLOOD PRESSURE MONITOR REF CHU503 1301 English...

Page 2: ...and tighten it so that one finger can be inserted between the cuff and arm See page 12 4 DO NOT measure your blood pressure after bathing or drinking 5 Measure your blood pressure where the room temp...

Page 3: ...o use only our authorized parts and accessories Parts and accessories not approved for use with the device may damage the unit 17 DO NOT use this unit on infants 18 Blood pressure measurement may not...

Page 4: ...oper function and performance Protect the nature environment Please help to protect natural environment by respecting national and or local recycling regulations when disposing of the battery and the...

Page 5: ...plied with the unit should be loaded in compartment before you use the blood pressure monitor LOADING THE BATTERIES 1 Open the cover of battery compartment Pressing the hook down pull the cover toward...

Page 6: ...U503 allows you to measure your blood pressure without having to worry about the amount of remaining charge in the batteries Warning The CHU503 and AC 230CZ should be used indoors in dry location USIN...

Page 7: ...ion of the cuff so that the blue marker is located in the center of your arm and the hem of the cuff is 1 2 cm for Cuff 2 3 cm for Large cuff above your elbow The cuff should be put on the bare arm or...

Page 8: ...surization is reached approximately 40 mmHg higher than the Systolic blood pressure You can stop pressurization by the unit by releasing the switch at the aforementioned value is reached The upper pre...

Page 9: ...FEATURE After taking the blood pressure measurement pressing the START STOP switch will turn the monitor off However if you do not press the switch the monitor s Auto OFF function will automatically t...

Page 10: ...cluding the systolic pressure that occurs when the heart pumps blood and the diastolic pressure that occurs when blood returns to the heart Your blood pressure changes all the time Your blood pressure...

Page 11: ...re readings and to determine the proper treatment Model number CHU503 Measurement system Oscillometric method Display Digital display type Measurement localization Upper Arm Cuff Soft cuff Cuff circum...

Page 12: ...Design and Specification are subject to change without notice CITIZEN is a registered trade mark of Citizen Holdings Co Japan...

Reviews: