Precautions for use

1.  If you suffer from heart disease, high blood pressure or other circulatory disease, 

consult your physician before using the monitor.

2.  If the cuff pressure feels abnormal or you experience any other irregularity while 

using the cuff, reduce the pressure immediately by pressing the “START/STOP” 
switch and then consult the sales outlet where you purchased the monitor.

3.  If you think the measurement is abnormal or if measurement makes you feel 

unwell, discontinue use and consult your physician.

4.  Blood pressure measurement may not be possible for anyone with a weak pulse 

or arrhythmia.

5.  Repeated blood pressure measurement may cause problems such as 

congestion or swelling in some people.

6.  Frequently repeated blood pressure measurements will not give accurate 

results. Allow an interval of about 10 minutes between measurements.

7.  If you suffer from a severe problem with blood circulation in your arms, consult 

your physician before using the monitor. Failure to do so could be hazardous to 
your health.

8.  Measurement may not be possible for anyone with insuf

fi

 cient blood 

fl

 ow to the 

area where measurements will be taken or who suffers from a frequent irregular 
heartbeat. Consult your physician for advice on whether to use the monitor.

9.  DO NOT wrap the cuff around an injured arm.

10.  DO NOT wrap the cuff around an arm in which a drip (intravenous infusion) 

is inserted, or which is being used for blood transfusion as part of medical 
treatment. Doing so could result in an injury or a serious accident.

11.  DO NOT use the monitor in the vicinity of 

fl

 ammable gases such as those used 

for anaesthesia. Doing so could ignite the gases and cause an explosion.

12.  DO NOT use the monitor in enriched oxygen environments such as a hospital’s 

hyperbaric chamber or oxygen tent. Doing so could ignite the oxygen and 
cause a 

fi

 re.

13.  DO NOT use mobile phones near the monitor as this could result in a 

malfunction.

14.  If you use a cardiac pacemaker, consult your physician before using the monitor.

PRECAUTIONS FOR USE AND MAINTENANCE

Summary of Contents for CH-432BS

Page 1: ...English INSTRUCTION MANUAL FOR DIGITAL BLOOD PRESSURE MONITOR REF CH 432BS 0701...

Page 2: ...ICATIONS OF PARTS 10 LOADING THE BATTERIES 11 REMOVING THE BATTERIES 12 USING AC ADAPTER OPTION 13 MEASURING YOUR BLOOD PRESSURE 20 KEY TO DISPLAY ICONS 21 ABOUT BLOOD PRESSURE 22 BLOOD PRESSURE Q A 2...

Page 3: ...arge number of readings 9 Emotional stress tends to cause your blood pressure to rise To obtain correct blood pressure measurements 1 Take five or six deep breaths and then relax before measuring your...

Page 4: ...e is only intended for use by adults Definitions and Classifications of Blood Pressure Levels Measure your blood pressure at the same time each day Your blood pressure changes all the time This means...

Page 5: ...n your arms consult your physician before using the monitor Failure to do so could be hazardous to your health 8 Measurement may not be possible for anyone with insufficient blood flow to the area whe...

Page 6: ...sassemble the monitor 5 DO NOT bend the cuff or the air hose excessively 6 If the monitor is very dirty wipe it clean with a cloth moistened with sterilizing alcohol or a neutral detergent Then wipe i...

Page 7: ...ms for used electronics products in accordance with legislation under the WEEE Directive Directive 2002 96 EC and is effective only within European Union Reference European standard The blood pressure...

Page 8: ...ARTS Component names START STOP Switch w Stand by Systolic blood pressure display Air hose socket Diastolic blood pressure Pulse display Pressurization setting switch Inflation level selector Pressuri...

Page 9: ...Eng 9 English IDENTIFICATION OF PARTS Battery cover Air hose connector Air hose Cuff Blue marker...

Page 10: ...Pressing the hook down pull the cover toward you to open 2 Place batteries in the compartment Put the batteries paying attention to the positive and negative terminal symbols and Battery cover Lug pro...

Page 11: ...or to changing batteries Do not use rechargeable batteries Do not use alkaline and manganese batteries together The monitor is powered by the batteries provided Note that they may not last as long as...

Page 12: ...power to the monitor the AC adapter should be unplugged from the monitor Leaving the AC adapter plugged into the blood pressure monitor could cause a malfunction Using the optional dedicated AC adapte...

Page 13: ...ve your elbow The cuff should be put on the bare arm or over a light weight underwear If you wear a heavy weight top please remove it 2 Put the arm cuff around your arm so that the blue marker comes t...

Page 14: ...to the Velcro 5 Place your arm on a table or the like so that the center of the cuff comes to the height of your heart Carefully place the cuff on your arm taking care to use the correct tightness The...

Page 15: ...y on the table so that your palm is facing up and your fingers are relaxed 4 Do not move your body or talk while taking the measurement Measurement in a reclining posture 1 Lie down facing the celling...

Page 16: ...r systolic blood pressure value around 130mmHg for example set to 160 Use the pressurization setting switch to select the pressurization setting from 130 160 200 or 250mmHg The pressurization setting...

Page 17: ...turns off 1 The measurement is displayed for approximately two seconds lights during the first measurement performed after the battery is replaced 2 The cuff is pressurized according to the chosen pr...

Page 18: ...he pressure value is displayed on the diastolic blood pressure display 5 Once measurement is complete the cuff deflates and the measurement results systolic diastolic blood pressure values pulse are d...

Page 19: ...OP switch The cuff is deflated and measurement stops 6 Finishing measurement AUTOMATIC POWER OFF FEATURE After taking the blood pressure measurement pressing the START STOP switch will turn the monito...

Page 20: ...Condition Cause Corrective action Insufficient pressure Appears when the blood pressure could not be measured accurately Apply cuff properly and measure again The pressure is 281 mmHg or higher If th...

Page 21: ...a range of other factors It is likely to be affected by your biorhythm during the day and by your posture physical activities mental activities level of stress and even by the air temperature The blo...

Page 22: ...onstant but it varies if you take measurements in repetition Blood pressure is susceptible to the time of day such as morning and afternoon season and atmospheric temperature In addition blood pressur...

Page 23: ...measurements can be taken Check whether the measurement icon is displayed Attach the arm cuff properly Check whether the arm cuff is applied correctly Did you stay calm during measurement Measure you...

Page 24: ...mmHg Deflation Automatic speed deflation system controlled by internal electromagnetic valve Rated voltage 6V DC 3W direct current Exhaust Electromagnetic quick exhaust valve Power supply 4 AA batteri...

Page 25: ...Design and Specification are subject to change without notice CITIZEN is a registered trade mark of Citizen Holdings Co Japan CITIZEN es una marca registrada de Citizen Holdings Co Jap n...

Reviews: