Citizen CH-403C Instruction Manual Download Page 3

After cleaning the cuff with a neutral detergent, lightly rinse it
with water and let it dry in the air.  Hard rubbing or washing

in a washing machine will cause air leakage.  Also, be careful
not to get water into the air hose.

General Remarks on blood pressure
measurement

• If the cuff is to be deflated quickly, depress “POWER” switch.
• The attached cuff is suited for an arm circumstance of 22cm to

32cm.

• When attaching the cuff, rubber cuff hose should be placed

on the inside of your arm on top of the arterial.

• Self measurement is no therapy! In no case may you change

the dosage of medication prescribed by your physician.

• In operation for blood pressure measurement, you should

urinate and should remain relatively still for 10 to 15 min-
utes prior to measurement.

• Exercise, eating and drinking, smoking, etc., prior to mea-

surement may affect the results.

• The blood pressure varies constantly throughout the day. Mea-

surement should be made regularly at the same time each day.

• Do NOT be impressed by the results of one measurement.

Keep a record of blood pressure variations. Many readings
tell a story.

• Emotional stress may tend to cause pressure to rise.

For proper measurement of blood pressure

• Take a deep breath five or six time and then relax before

measuring blood pressure.  If you are tense when taking
the measurement, you will not get a valid reading.

• Blood pressure will be elevated when you are in a worri-

some or irritated state, suffering from lack of sleep or con-
stipation, or after exercise or a meal.

• Putting on the cuff is one of the most important tasks for

ensuring proper measurement of blood pressure. Wind the
cuff around the arm and tighten it so that one finger may
be inserted between the cuff and arm.

• Do NOT measure blood pressure after bathing or drinking.
• When you feel like relieving yourself, you should do so be-

fore measuring blood pressure.

• Measure blood pressure where the room temperature is

about 20˚C. Do NOT measure blood pressure when it is too
cold (below 10˚C) or too hot (above 40˚C) in the room.

• Do NOT measure blood pressure immediately after drink-

ing coffee or tea or smoking.

CLEANING METHOD OF CUFF

GENERAL REMARKS

English

Eng 3

 -

Summary of Contents for CH-403C

Page 1: ...ORY START POWER SELECT IDENTIFICATION OF PARTS Systolic blood pressure display section Diastolic blood pressure Pulse display section Cuff Rubber cuff hose Hose plug Hose socket Memory reset switch Ba...

Page 2: ...mprovements being made Oscillometric system Digital display Height 19mm Pressure 0 280mmHg Pulse 40 200 beat min Pressure 3mmHg Pulse 5 Automatic inflation by internal pump 4 stage 130 160 200 250mmHg...

Page 3: ...impressed by the results of one measurement Keep a record of blood pressure variations Many readings tell a story Emotional stress may tend to cause pressure to rise For proper measurement of blood pr...

Page 4: ...r re placement etc and a record should be kept of any neces sary data Do NOT keep on measuring so many times as your arm will have built up congestion of blood and you will not get a valid reading PRE...

Page 5: ...nd EN 1060 3 1997 Noninvasive Sphygmo manometers Part 3 Supplementary Requirements for Electromechanical Blood Pressure Measuring Systems Manufacturer Name Premier Precision Ltd Address Block E G H 6t...

Page 6: ...etting value appears for approx 3 seconds Then the 0 appears at the display Ready for measurement 2 Attaching of arm cuff and posture during measurement Unfasten and open the cuff as figure SYSTOLIC m...

Page 7: ...will constrict the up per arm and prevent accurate measurement Rubber cuff hose should be placed on the inside of your arm as figures The cuff should be wound so that one finger can be in serted under...

Page 8: ...of the display CH 403C MEMORY START POWER SELECT Press the Start Switch The arm cuff pressurizes when the Start Switch is pressed 4 To start the measurement SYSTOLIC mmHg DIASTOLIC mmHg PULSE min AVE...

Page 9: ...he display 2 or 3 seconds later pressure value and pulse appear alter nately on the display SYSTOLIC mmHg DIASTOLIC mmHg PULSE min AVE 1 2 3 4 5 6 7 CH 403C MEMORY START POWER SELECT 6 Subsequent meas...

Page 10: ...d The mark shifts to right from Ave to 1 and notify that the value is the last measured newest one value Press the Memory Recall Switch to recall the last mea sured blood pressure The last measured sy...

Page 11: ...od pressure value is stored in memory at press ing Power Switch for turn OFF or at pressing Start Switch for new measurement 10 Battery replacement If the batteries become weak the mark will appear in...

Page 12: ...the cuff properly and remeasure Appears when the pulse could not ac curately be measured Replace the batteries Appears when the batteries become weak Appears when no memory is stored at pressing of M...

Page 13: ...EN is a registered trademark of Citizen Watch Co Japan Consumer Electronics Division CBM Bldg 5F 5 68 10 Nakano Nakano ku Tokyo 164 0001 Japan Phone 03 5345 7430 Fax 03 5345 7431 E mail info con jcbm...