Citizen CH-403C Instruction Manual Download Page 1

INSTRUCTION MANUAL

FOR

DIGITAL BLOOD PRESSURE MONITOR

REF  CH-403C

TM

English

  CH-403C

MEMORY

START

POWER

SELECT

IDENTIFICATION OF PARTS

Systolic blood pressure
display section

Diastolic blood pressure/
Pulse display section

Cuff

Rubber cuff hose

Hose plug

Hose socket

Memory reset switch

Battery cover

Power switch

Start switch

Memory recall switch

Pressure setting switch

Eng 1

 -

Summary of Contents for CH-403C

Page 1: ...ORY START POWER SELECT IDENTIFICATION OF PARTS Systolic blood pressure display section Diastolic blood pressure Pulse display section Cuff Rubber cuff hose Hose plug Hose socket Memory reset switch Ba...

Page 2: ...mprovements being made Oscillometric system Digital display Height 19mm Pressure 0 280mmHg Pulse 40 200 beat min Pressure 3mmHg Pulse 5 Automatic inflation by internal pump 4 stage 130 160 200 250mmHg...

Page 3: ...impressed by the results of one measurement Keep a record of blood pressure variations Many readings tell a story Emotional stress may tend to cause pressure to rise For proper measurement of blood pr...

Page 4: ...r re placement etc and a record should be kept of any neces sary data Do NOT keep on measuring so many times as your arm will have built up congestion of blood and you will not get a valid reading PRE...

Page 5: ...nd EN 1060 3 1997 Noninvasive Sphygmo manometers Part 3 Supplementary Requirements for Electromechanical Blood Pressure Measuring Systems Manufacturer Name Premier Precision Ltd Address Block E G H 6t...

Page 6: ...etting value appears for approx 3 seconds Then the 0 appears at the display Ready for measurement 2 Attaching of arm cuff and posture during measurement Unfasten and open the cuff as figure SYSTOLIC m...

Page 7: ...will constrict the up per arm and prevent accurate measurement Rubber cuff hose should be placed on the inside of your arm as figures The cuff should be wound so that one finger can be in serted under...

Page 8: ...of the display CH 403C MEMORY START POWER SELECT Press the Start Switch The arm cuff pressurizes when the Start Switch is pressed 4 To start the measurement SYSTOLIC mmHg DIASTOLIC mmHg PULSE min AVE...

Page 9: ...he display 2 or 3 seconds later pressure value and pulse appear alter nately on the display SYSTOLIC mmHg DIASTOLIC mmHg PULSE min AVE 1 2 3 4 5 6 7 CH 403C MEMORY START POWER SELECT 6 Subsequent meas...

Page 10: ...d The mark shifts to right from Ave to 1 and notify that the value is the last measured newest one value Press the Memory Recall Switch to recall the last mea sured blood pressure The last measured sy...

Page 11: ...od pressure value is stored in memory at press ing Power Switch for turn OFF or at pressing Start Switch for new measurement 10 Battery replacement If the batteries become weak the mark will appear in...

Page 12: ...the cuff properly and remeasure Appears when the pulse could not ac curately be measured Replace the batteries Appears when the batteries become weak Appears when no memory is stored at pressing of M...

Page 13: ...EN is a registered trademark of Citizen Watch Co Japan Consumer Electronics Division CBM Bldg 5F 5 68 10 Nakano Nakano ku Tokyo 164 0001 Japan Phone 03 5345 7430 Fax 03 5345 7431 E mail info con jcbm...

Reviews: