Fan rubs when turning:

  call CITC for instructions.  Do not remove cover. 

 

Motor jumps or is unsteady:

  check extension cord for low gauge.  Turn off any other 

loads sharing the same circuit or test in dedicated outlet. 

 

Fan starts slowly:

 Check extension cord for low gauge. Turn off any other loads sharing 

the same circuit or test in dedicated outlet. 

 

5.7  Notes on optional DMX FX-15 Switchpack operation

 

 

Each DMX’d unit will occupy a unique DMX address on the DMX chain.  By adjusting the 
dip switches on the side of the machine near the DMX cable plug-ins, the user may 
assign one address to the machine, giving you on/off and volume control with one DMX 
channel (there is no timer on this DMX).   

 

Step 1).  

Attach the DMX cable to the upper “in” female connector located on the end

 

 of the fan.  

Step 2).  

The DMX address is configured by adding the dip switch numbers together 

to total the number required.  For example, DipSwitch 1 + 6 = 33.  Your DMX channel 
would be 33.   

 

Dip Switch 

  8 

  9 

Channel # 

16 

32 

64 

128 

256 

 

When you move the slide control or digital control to approximately the 50% 
position the fan will turn on. 

 

0 – 50% 

 

=  Off  

51– 100%  

 

=  On 

 

 “Input” and “Output” designations on the DMX plugs are arbitrary (i.e., you can use the 
input plug for output and visa-versa). It is not necessary to attempt converting your DMX 
line’s connector to female/male to match the appropriate socket on the plug. As long as it 
is looped in/out, it will work. 

 
 
 
 
 

 

 

 

 

 

 

 

6. 

Service and Maintenance

 

 

Summary of Contents for Hurricane II 100157

Page 1: ...HURRICANE II FLOOR MODEL FAN Operating Instructions P N 100157 120V P N 100158 230V...

Page 2: ...ntee perfect and successful work with this machine please take some time to read the manual carefully o And finally we believe you will enjoy many years of dependable trouble free service if you prope...

Page 3: ...Unpacking the Hurricane II Floor Model Fan 5 2 Electrical Power Requirements 5 3 Running the Hurricane II Floor Model Fan 5 4 Transporting the Hurricane II Floor Model Fan 5 5 Optional DMX FX 15 Switc...

Page 4: ...3...

Page 5: ...ane II Floor Model Fan weighs just 38 lbs 17 2kg 4 Safety Instructions WARNING Read and understand all labels and operating instructions before attempting installation o RISK OF ELECTRICAL SHOCK This...

Page 6: ...ning the Hurricane II Floor Model Fan 1 Quickly turn on then off the power and check to see if the fan is moving easily without rubbing the edge Sometimes in shipping the fan may be damaged due to mis...

Page 7: ...me control with one DMX channel there is no timer on this DMX Step 1 Attach the DMX cable to the upper in female connector located on the end of the fan Step 2 The DMX address is configured by adding...

Page 8: ...use water around the electrical connections 5 Inspect the cord for damage before each use 6 Never operate with extension cords that are under 12 awg 7 Technical Data Hurricane II Floor Model Fan P N 1...

Page 9: ...ion is not covered by this warranty Using any fluid other than what is recommended for this machine will void warranty No liability is accepted for injury or for loss damage or expense resulting from...

Page 10: ...ight costs to and from CITC when under the limited warranty services are the responsibility of the customer Customer must place appropriate insurance on return of product However if product is returne...

Reviews: