Electric connection
The connection needs to be made in the wiring box at the back. Open the coverplate
(G) in order to reach the connection clamps.
The connection cable needs to be brought in through the opening on the
side of the
wiring box.
It is necessary to
ground
the dryer for your personal safety and to ensure a good
operation.
115 and 208-240 V - 1 ph
The mains wires
(Ll)
and
(L2)
should be connected to the 2 left blocks and the
yellow/green grounding wire (PE)
should be connected to the grounding block.
208-240 and 480 V - 3 ph
The
3 mains wires (L1), (L2) and (L3)
should be connected to the 3 left blocks and
the
yellow/green grounding wire (PE)
should be connected to the grounding
block.
380-415V - 3 ph
The
3 mains wires (L1), (L2) and (L3)
should be connected to the 3 left blocks,
the
blue neutral (N)
should be connected to the right block and the
yellow/green
grounding wire (PE)
should be connected to the grounding block.
G
Dryers must be electrically grounded by a separate #14 or larger green wire from the grounding terminal
within the Service Connection Box, to a cold water pipe. In all cases, the grounding method must comply
with local electrical code requirements; or in the absence of local codes, with the
National Electrical Code,
ANSI/NFPA 70 or the Canadian Electrical Code, CA C22.1.
See wiring diagram furnished with dryer.
Do not change wiring without consulting the factory, as you may
void the factory warranty. DO NOT CONNECT THE DRYER TO ANY VOLTAGE OR CURRENT OTHER
THAN THAT SPECIFIED ON THE DRYER RATING PLATE. (Wiring diagram is located on rear wall of dryer.)
All panels must be in position before operation of dryer.