background image

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

Maintenance

AJ1032

14

Cleaning Press Head

Cleaning press head is periodically required. Press 
head requires cleaning if discoloration transfers from 
head to garments or garments stick to head as it opens.

Once precautions in above WARNINGS have been 
met, follow directions provided with surface cleaner.

Time Intervals

Operation or Inspection

Corrective Action

Daily or as required

Visually inspect sight glass in air line filter at 
inlet. (Refer to Item 4, 

Figure 4

.)

If moisture and oil are collecting in bowl, auto-
drain is not working. Clean, repair or replace 
auto-drain.

Check buck padding.

Clean padding. Replace padding if it is torn or 
brittle or has burn spots.

Visually inspect press head for discoloration or 
stickiness.

Clean press head with a head surface cleaner as 
needed.

Weekly

Inspect air line filter for sediment.

Clean air filter if dirt is present.

Inspect all safety labels. Refer to Parts Manual 
for location and description of labels.

Replace labels which are damaged, missing or 
unreadable.

Every two weeks

Inspect steam strainers in steam inlet and outlet 
lines and in traps.

Clean steam strainer if dirt is present.

Monthly

Inspect customer-furnished steam traps per 
instructions provided with traps.

Clean customer-furnished steam traps if dirt is 
present.

Check all steam and air connections for visual 
signs of leakage.

Tighten any loose connections. Replace lines 
where necessary.

Check condition of the flexible steam hoses.

Replace steam hoses with broken braids.

Every six months

Remove all covers and check cap screws, 
fittings and cylinders for security of 
attachment.

Tighten as required.

Table 2 

To avoid possible serious injury, heads 
should be cleaned ONLY by properly 
trained personnel.

W342

WARNING

To avoid possible serious injury, ALWAYS 
shut off services to press BEFORE 
cleaning press heads:
• Shut off AND lock out ALL electric power 

to press.

• Shut off AND lock out ALL air pressure to 

press using relieving shut-off valve at air 
supply inlet.

• Reduce to zero AND lock out ALL steam 

pressure to press.

• Let heated surfaces cool.

W343

WARNING

If using a surface cleaner which requires 
heat to the press, use industry approved 
heat protective mitt or other heat protective 
device as press heads are cooling down.

W344

WARNING

Summary of Contents for AJ1032

Page 1: ...1292 Sales Fax 502 585 3625 Service Parts Fax 502 681 1275 www cissellmfg com Mighty Mite and Super Laundry Presses Refer to Page 3 for Model Numbers SCR1529C SCR1529C Part No AJ1032 February 2005 Ke...

Page 2: ......

Page 3: ...ety Instructions 5 Introduction 7 Nameplate Location 7 Parts Ordering Information 7 General Description 7 Optional Equipment 7 Operation 9 Operating Controls 9 Pre Operating Services 10 Press Operatio...

Page 4: ...Copyright Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 2 AJ1032 Notes...

Page 5: ...Copyright Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 3 AJ1032 Model Identification Information in this manual is applicable to the following models LDBB CMMBB LDCC CMMCCY...

Page 6: ...Copyright Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT AJ1032 4 Notes...

Page 7: ...Do not tamper with the controls 7 Do not repair or replace any part of the press or attempt any servicing unless specifically recommended in the user maintenance instructions or in published user repa...

Page 8: ...igns and labels are also placed on the press Those signs and labels are limited messages Where needed further explanations are provided in the manual These signs are to be inspected for readability an...

Page 9: ...essing of damp garments Major press components are Steam heated head and buck One air cylinder dedicated to closing head AND automatically apply pressing pressure once head is closed An adjustable muf...

Page 10: ...Copyright Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT AJ1032 8 Notes...

Page 11: ...ut off and lockout valve REGULATOR Reduces supply air pressure to operating air pressure 80 psi Adjust air pressure regulator so operating air pressure is 80 5 psi DOWNSTREAM AIR RELIEVING SHUT OFF AN...

Page 12: ...heat Press Operation One complete pressing operation is described in the following steps Presses WITHOUT Timers or Presses WITH Timer Set to OFF Position 1 Perform pre operating services 2 If press i...

Page 13: ...can be opened at any time during timer controlled pressing by pressing OPEN pushbutton Item 5 Figure 2 6 Hang or fold pressed article as soon as possible to preserve finish Post Operating Services Per...

Page 14: ...Copyright Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT AJ1032 12 Notes...

Page 15: ...actions to be taken are listed in Table 2 To avoid possible serious injury ALWAYS shut off services to press BEFORE doing ANY maintenance service setup adjustments or repair tasks Shut off AND lock o...

Page 16: ...or unreadable Every two weeks Inspect steam strainers in steam inlet and outlet lines and in traps Clean steam strainer if dirt is present Monthly Inspect customer furnished steam traps per instructio...

Page 17: ...oline or toluene which are damaging to plastic sight glass 4 Reassemble per notes from step 2 Ensure o ring is in position on filter bowl Tighten bowl to filter body Tighten slightly more than hand ti...

Page 18: ...nths Use a premium high temperature EP2 grease Lubricate with one shot of grease from a low pressure grease gun If rod end fittings do not have grease fittings squirt a few drops of oil on rod ends B...

Page 19: ...Copyright Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT Maintenance 17 AJ1032 Figure 3 SCR102N B0159 INSPECTION AND LUBRICATION POINTS A C B A SYMBOLS GREASE GUN OIL CAN D...

Page 20: ...To decrease flow rate turn adjusting screw clockwise Likewise turn counterclockwise to increase oil flow 3 Use ISO VG 32 grade oil refer to Table 3 Refer to Filling Air Line Lubricator for filling ins...

Page 21: ...re with a pyrometer or comparable measuring device Head temperature should be 325 to 340 F If temperature is below recommended range review possible causes below Clogged steam strainer Clean steam str...

Page 22: ......

Reviews: