2-38
Cisco XR 12000 Series Router SIP and SPA Hardware Installation Guide
OL-17438-04
Chapter 2 Overview: Cisco XR 12000 Series Router Shared Port Adapters
1-Port OC-192/STM-64 POS SPA Overview
The 1-Port OC-192/STM-64 POS/RPR SPA LEDs are described in
1-Port OC-192/STM-64 POS/RPR SPA Interface Specifications
The 1-Port OC-192/STM-64 POS/RPR SPA contains a SONET/SDH framer to process
incoming and
outgoing SONET or SDH frames. The framer operates at OC-192/STM-64 line rates (9.95 Gbps).
Packet data is transported with a user-configured encapsulation (such as Point-to-Point Protocol [PPP])
and is mapped into the STS-192/STM-64 frame.
The 1-Port OC-192/STM-64 POS/RPR SPA interface is compliant with the following RFCs:
•
RFC 1619,
PPP over SONET/SDH
•
RFC 1662,
PPP in HDLC-like Framing
•
RFC 2615, PPP over SONET/SDH
The 1-Port OC-192/STM-64 POS/RPR SPA also provides support for SNMP v1 agent (RFC 1155–1157)
and RFC 1213:
•
RFC 1155,
Structure and Identification of Management Information for TCP/IP-Based Internets
•
RFC 1156,
Management Information Base for Network Management of TCP/IP-Based Internets
•
RFC 1157,
Simple Network Management Protocol (SNMP)
Table 2-30
1-Port OC-192/STM-64 POS/RPR SPA LEDs
LED Label
Color
State
Meaning
WRAP
Off
Off
Port is not in wrap mode.
Green
On
Port is in wrap mode somewhere on the ring.
Amber
On
Port is in wrap mode locally.
PASSTHRU
Off
Off
Port is not in pass-thru mode.
Amber
On
Port is in pass-thru mode.
MATESYNC
Off
Off
Mate port is not synchronized.
Green
On
Mate port is synchronized.
CARRIER
Off
Off
Port is not enabled by software.
Green
On
Port is enabled by software; there is a valid SONET signal
without alarms.
Amber
On
Port is enabled by software; there is at least one alarm (LOS,
LOF, RDI, and so on).
Blinking
Indicates SRP mode mismatch alarm.
ACTIVE
Off
Off
Port is not enabled by software.
Green
On
Port is enabled by software; loopback is off.
Amber
On
Port is enabled by software; loopback is on.
STATUS
Off
Off
SPA power off.
Green
On
SPA is ready and operational.
Amber
On
SPA power is on and good; SPA is being configured.