Cisco UCS C460 M2 High-Performance Rack-Mount Server
TECHNICAL SPECIFICATIONS
55
Environmental Specifications
The power specifications for the C460 M2 server are listed in
Table 31
.
Compliance Requirements
The regulatory compliance requirements for C-Series servers are listed in
Table 32
.
Table 31 UCS C460 M2 Environmental Specifications
Parameter
Minimum
Temperature operating
10°C to 35°C (50°F to 95°F)
Temperature nonoperating
-40°C to 70°C (-40°F to 158°F)
Altitude
-30 m to 1500 m (-100 ft to 5000 ft)
Humidity nonoperating
95%, noncondensing at temperatures of 25ºC (77ºF) to 30ºC (86ºF)
Table 32 UCS C-Series Regulatory Compliance Requirements
Parameter
Description
Regulatory Compliance
Products should comply with CE Markings per directives
2004/108/EC and 2006/95/EC
Safety
UL 60950-1 Second Edition
CAN/CSA-C22.2 No. 60950-1 Second Edition
EN 60950-1 Second Edition
IEC 60950-1 Second Edition
AS/NZS 60950-1
GB4943 2001
EMC - Emissions
47CFR Part 15 (CFR 47) Class A
AS/NZS CISPR22 Class A
CISPR22 Class A
EN55022 Class A
ICES003 Class A
VCCI Class A
EN61000-3-2
EN61000-3-3
KN22 Class A
CNS13438 Class A
EMC - Immunity
EN55024
CISPR24
EN300386
KN24