3-8
Cisco UCS C240 M4 Server Installation and Service Guide
OL-32474-01
Chapter 3 Maintaining the Server
Status LEDs and Buttons
Internal Diagnostic LEDs
The server is equipped with a supercap voltage source that can activate internal component fault LEDs
up to 30 minutes after AC power is removed. The server has internal fault LEDs for CPUs, DIMMs, fan
modules, SD cards, the RTC battery, and the mLOM card.
To use these LEDs to identify a failed component, press the front or rear Unit Identification button (see
or
) with AC power removed. An LED lights amber to indicate a faulty component.
See
for the locations of these internal LEDs.
Figure 3-3
Internal Diagnostic LED Locations
1
Fan module fault LEDs (one on each fan
module)
4
SD card fault LEDs
2
DIMM fault LEDs (one directly in front of
each DIMM socket on the motherboard)
5
RTC battery fault LED (under PCIe riser 1)
3
CPU fault LEDs
6
mLOM card fault LED (under PCIe riser 1)
Table 3-4
Internal Diagnostic LEDs, Definition of States
LED Name
State
Internal diagnostic LEDs (all)
•
Off—Component is functioning normally.
•
Amber—Component has a fault.
352952
FA
N
0
6
1
2
3
F
A
N 05
FA
N
0
4
FA
N
0
3
F
A
N 02
FA
N
0
1
CPU
1
CPU 2
SD1
SD2
Riser 2
Riser 1
4
6
5
Summary of Contents for UCS C240 M4
Page 8: ...Contents viii Cisco UCS C240 M4 Server Installation and Service Guide OL 32474 01 ...
Page 12: ...xii Cisco UCS C240 M4 Server Installation and Service Guide OL 32474 01 ...
Page 14: ...xiv Cisco UCS C240 M4 Server Installation and Service Guide OL 32474 01 ...
Page 16: ...xvi Cisco UCS C240 M4 Server Installation and Service Guide OL 32474 01 ...
Page 26: ...1 10 Cisco UCS C240 M4 Server Installation and Service Guide OL 32474 01 Chapter 1 Overview ...