C-2
Cisco UCS C240 M4 Server Installation and Service Guide
OL-32474-01
Appendix C RAID Controller Considerations
Supported RAID Controllers and Required Cables
Supported RAID Controllers and Required Cables
This server supports the RAID controllers and cable requirements shown in
.
Caution
In a SFF 8-drive server, do not use the embedded software RAID controller and a hardware RAID
controller card to control the front-facing drives at the same time. This combination is not supported and
could result in data loss. You can use the embedded software RAID controller to control internal SAS SSD
boot drives (SFF 24-drive and LFF 12-drive server versions only) while you use a hardware RAID
controller card to control the front-facing drives.
Note
See
Support Matrix For Cisco UCS C240 M4 Server RAID Controllers, page C-4
for information about
controller support by server version and drive type.
Table C-1
Cisco UCS C240 M4 RAID Options
Controller
Style
Supported Server Version/
Maximum Front-Facing Drives
Controlled
SCPM RAID Levels
Required Cables
Embedded RAID
(PCH SATA)
On
board
•
SFF 8-drives/no expander:
8 internal SATA drives
No
0, 1, 5
1
, 10
1.
Embedded RAID 5 support requires an optional RAID 5 key module.
•
SFF 8-drives/no expander:
Cable and required SATA
interposer board bundled as
UCSC-IP-PCH-C240M4=
Cisco UCS 12G SAS
Modular RAID
Controller
This controller can be
ordered with modular
flash-based write
cache (FBWC)
options: 1 GB, 2 GB,
or 4 GB.
PCIe
•
SFF 8-drives/no expander:
8 internal drives
•
SFF 16-drives/expander:
16 internal drives
•
SFF 24-drives/expander:
24 internal drives
•
LFF 12-drives/expander:
12 internal drives
Yes
2
2.
SCPM = SuperCap power module (RAID backup unit). See
Variable by cache
size:
•
No cache:
0, 1, 10
•
1GB, 2GB, or
4GB cache:
0, 1, 5, 6, 10, 50,
60
•
SFF 8-drives/no expander:
(
UCS-240CBLMR8=
)
•
SFF 16 drives/expander:
(
UCS-240CBLMR16=
)
•
SFF 24 drives/expander:
(
UCS-240CBLMR24=
)
•
LFF 12 drives/expander:
(
UCS-240CBLMR12=
)
Cisco UCS 12G SAS
Modular HBA
Note: See also
Write-Cache Policy
for Cisco 12G SAS
Modular RAID
Controller, page C-3
PCIe
•
SFF 8-drives/no expander:
8 internal drives
•
SFF 16-drives/expander:
16 internal drives
•
SFF 24-drives/expander:
24 internal drives
•
LFF 12-drives/expander:
12 internal drives
No
Non-RAID
•
SFF 8-drives/no expander:
(
UCS-240CBLMR8=
)
•
SFF 16 drives/expander:
(
UCS-240CBLMR16=
)
•
SFF 24 drives/expander:
(
UCS-240CBLMR24=
)
•
LFF 12 drives/expander:
(
UCS-240CBLMR12=
)
Cisco UCS SAS
9300-8e HBA
Note: See also
UCS SAS 9300-8e
HBA Considerations,
page C-4
PCIe
•
All server versions
8 external SAS+SATA
ports, controlling up to
1024 non-RAID external
drives
No
Non-RAID
•
External storage cables are
not sold by Cisco.
NOTE: This HBA does not
support optical cables for
connection to external storage
(copper only).
Summary of Contents for UCS C240 M4
Page 8: ...Contents viii Cisco UCS C240 M4 Server Installation and Service Guide OL 32474 01 ...
Page 12: ...xii Cisco UCS C240 M4 Server Installation and Service Guide OL 32474 01 ...
Page 14: ...xiv Cisco UCS C240 M4 Server Installation and Service Guide OL 32474 01 ...
Page 16: ...xvi Cisco UCS C240 M4 Server Installation and Service Guide OL 32474 01 ...
Page 26: ...1 10 Cisco UCS C240 M4 Server Installation and Service Guide OL 32474 01 Chapter 1 Overview ...