background image

Cisco UCS C24 M3 High-Density SFF Rack-Mount Server

CONFIGURING the SERVER

11

STEP 3

SELECT MEMORY

The standard memory features are:

DIMMs

— Clock speed: 1333 or 1600 MHz

— Ranks per DIMM: 1 or 2

— Operational voltage: dual voltage capable (1.5 V or 1.35 V)

— Registered ECC DDR3 DIMMS (RDIMMS)

Memory is organized with three memory channels per CPU, with up to two DIMMs per 
channel, as shown in 

Figure 4

.

Figure 4

  C24 M3 SFF Memory Organization

Summary of Contents for UCS C24 M3

Page 1: ...CISCO SYSTEMS PUBLICATION HISTORY 170 WEST TASMAN DR SAN JOSE CA 95134 REV A 1 NOVEMBER 2 2012 WWW CISCO COM Cisco UCS C24 M3 High Density Small Form Factor Rack Mount Server ...

Page 2: ...AGEMENT ARM 28 STEP 11 ORDER A TRUSTED PLATFORM MODULE 29 STEP 12 ORDER OPTIONAL USB 2 0 DRIVES 30 STEP 13 SELECT OPERATING SYSTEM 31 STEP 14 SELECT OPERATING SYSTEM MEDIA KIT 33 STEP 15 SELECT OPTIONAL VALUE ADDED SOFTWARE 34 STEP 16 SELECT SERVICE and SUPPORT LEVEL 35 OPTIONAL STEP ORDER RACK s 39 OPTIONAL STEP ORDER PDU 40 SUPPLEMENTAL MATERIAL 41 CHASSIS 41 CPUs and DIMMs 42 Physical Layout 42...

Page 3: ... the capabilities of the Cisco UCS portfolio in a 2 RU form factor with the Intel Xeon processor E5 2400 series processor family CPUs which deliver the best combination of performance flexibility and efficiency gains In addition the Cisco UCS C24 M3 offers up to 12 DIMM slots 24 disk drives 5 PCIe slots and two 1 Gigabit Ethernet LAN on motherboard LOM ports to provide exceptional levels of intern...

Page 4: ... activity LED Power supply status LED Temperature status LED Fan Status LED System status LED 2 Pull out asset tag 5 Identification button LED 3 Drives hot swappable up to twenty four 2 5 inch drives for the 24 drive backplane option 6 Power button power status LED 285250 HDD 01 HDD 02 HDD 03 HDD 04 HDD 05 HDD 06 HDD 07 HDD 08 HDD 09 HDD 10 HDD 11 HDD 12 HDD 13 HDD 14 HDD 15 HDD 16 HDD 17 HDD 18 H...

Page 5: ...cated management port 3 PCIe half height slots 3 4 and 5 on riser 2 x16 PCIe Gen 3 slot x16 connector half length half height 8 Rear Identification button LED 4 USB ports 4 9 PCIe full height slots 1 and 2 on riser 1 x16 PCIe Gen 3 slot x16 extended connector Cisco CNIC half length full height 5 Serial port DB 9 connector PSU 2 PSU 2 PSU 2 PCIe 4 PCIe 4 PCIe 4 PCIe 3 PCIe 3 PCIe 3 PCIe 1 PCIe 1 PC...

Page 6: ...CIe Gen 3 slot x8 connector half length full height no NCSI support Riser 2 controlled by CPU 2 One x8 PCIe Gen 3 slot x16 connector half length half height One x8 PCIe Gen 3 slot x8 connector half length half height One x8 PCIe Gen 3 slot x8 connector half length half height Storage controller The 24 drive version of the server supports the following RAID controllers RAID plug in controller card ...

Page 7: ...front panel controller provides status indications and control buttons Power subsystem One or two power supplies depending on server configuration and loading Power supplies available are 450 W or 650 W no mixing With two power supplies 1 1 redundancy is provided if the load can be carried with one supply Prior to making a power supply selection the UCS Power Calculator should be run to determine ...

Page 8: ...PCIe OPTION CARD s page 19 STEP 7 ORDER OPTIONAL NETWORK CARD ACCESSORIES page 21 STEP 8 SELECT AC POWER CORD s page 24 STEP 9 ORDER POWER SUPPLIES page 27 STEP 10 ORDER OPTIONAL REVERSIBLE CABLE MANAGEMENT ARM page 28 STEP 11 ORDER A TRUSTED PLATFORM MODULE page 29 STEP 12 ORDER OPTIONAL USB 2 0 DRIVES page 30 STEP 13 SELECT OPERATING SYSTEM page 31 STEP 14 SELECT OPERATING SYSTEM MEDIA KIT page ...

Page 9: ...uct ID PID of the server as shown in Table 2 The Cisco C24 M3 server Includes a rail kit Does not include power supply CPU memory hard disk drives HDDs or plug in PCIe cards Table 2 PID of the C24 M3 High Density SFF Rack Base Server Product ID PID Description UCSC C24 M3S UCS C24 M3 SFF with rail kit without PSU CPU memory HDD or PCIe cards NOTE Use the steps on the following pages to configure t...

Page 10: ...Ms whose speeds are lower or higher than that shown in the tables suboptimal performance will result Table 3 Available Intel CPUs Xeon E5 24xx Series Product ID PID Intel Number Clock Freq GHz Power W Cache Size MB Cores QPI Highest DDR3 DIMM Clock Support MHz 1 Notes 1 If higher or lower speed DIMMs are selected than what is shown in the table for a given CPU the DIMMs will be clocked at the lowe...

Page 11: ...emory features are DIMMs Clock speed 1333 or 1600 MHz Ranks per DIMM 1 or 2 Operational voltage dual voltage capable 1 5 V or 1 35 V Registered ECC DDR3 DIMMS RDIMMS Memory is organized with three memory channels per CPU with up to two DIMMs per channel as shown in Figure 4 Figure 4 C24 M3 SFF Memory Organization ...

Page 12: ...from the other channel A transient or soft error in one channel does not affect the mirrored data and operation continues unless there is a simultaneous error in exactly the same location on a DIMM and its mirrored DIMM Memory mirroring reduces the amount of memory available to the operating system by 50 because only one of the two populated channels provides data Table 4 Available DDR3 DIMMs Prod...

Page 13: ... 1X162RY A DIMMs Also the sum of all PIDs must adhere to the maximum quantity rule of 12 DIMMs for 2 CPU systems By default all DIMMs run at 1 35 V which yields 1333 MHz memory speeds To run the memory DIMMS at 1600 MHz you need to go into the BIOS or set the policy with UCSM service profile to run in Performance Mode This forces the DIMMs to operate at 1 5 V and yields 1600 MHz speeds provided Th...

Page 14: ...ription RAID Controllers UCS RAID 9265CV LSI MegaRAID 9265CV 8i with SuperCap power backup Supports up to 24 internal SAS or SATA drives SAS and SATA drives can be mixed Includes a 1 GB Transportable Memory Module TMM cache and SuperCap power module for data cache backup RAID levels supported RAID 0 1 10 5 50 6 60 see the RAID Configuration Options section later in this table UCSC RAID 9240 8I LSI...

Page 15: ...xactly two drives with the same size speed capacity R2XX RAID5 Factory preconfigured RAID option Enable RAID 5 Setting Requires a minimum of three drives of the same size speed capacity R2XX RAID6 Factory preconfigured RAID option Enable RAID 6 Setting Requires a minimum of four drives of the same size speed capacity R2XX RAID10 Factory preconfigured RAID option Enable RAID 10 Setting Requires an ...

Page 16: ...lug in PCIe RAID controller cards are all half height You can choose an optional RAID configuration RAID 0 1 5 6 or 10 which is preconfigured at the factory The RAID level you choose must be an available RAID choice for the controller selected RAID levels 50 and 60 are supported depending on the RAID controller selected although they are not available as configuration options No RAID factory preco...

Page 17: ...apacity HDDs A03 D146GC2 146 GB 6Gb SAS 15K RPM SFF SAS 146 GB UCS HDD300GI2F105 300 GB 6Gb SAS 15K RPM SFF SAS 300 GB A03 D300GA2 300 GB 6Gb SAS 10K RPM SFF SAS 300 GB A03 D500GC3 500 GB SATA 7 2K RPM SFF SATA 500 GB A03 D600GA2 600 GB 6Gb SAS 10K RPM SFF SAS 600 GB UCS HDD900GI2F106 900 GB 6Gb SAS 10K RPM SFF SAS 600 GB A03 D1TBSATA 1 TB SATA 7 2K RPM SFF SATA 1 TB NOTE No factory configured RAI...

Page 18: ...n page 17 2 LSI MegaRAID 9240 8i or LSI MegaRAID 9220 8i For the 24 drive backplane with expander option select up to 16 drives listed in Table 6 on page 17 Caveats You can mix SATA and SAS drives No factory configured RAID option can be chosen a factory RAID volume is not available if there are no drives or SAS and SATA drives are mixed or different capacity drives are mixed If you select one or ...

Page 19: ...o be confused with 40 GbE QSFP Qlogic QLE8242 CU dual port 10 GbE FCoE CNA Half UCSC PCIE ESFP Emulex OCe11102 FX dual port 10 GbE FCoE CNA Half Network Interface Cards NICs N2XX ABPCI01 M3 Broadcom 5709 Dual Port Ethernet PCIe Adapter w TOE for M3 Servers Half N2XX ABPCI03 M3 Broadcom 5709 Quad Port 10 100 1Gb NIC w TOE iSCSI for M3 Servers Half UCSC PCIE BTG Broadcom 57712 Dual Port 10GbE 10G Ba...

Page 20: ...slot except the Cisco 1225 VIC card which must be installed in the half length full height slot slot 1 of riser 1 The Cisco 1225 VIC card must be plugged into slot 1 which supports NCSI Additional considerations for the Cisco 1225 VIC card Supports 10G SFP optical and copper twinax connections Supported only in PCIe slot 1 of this server Slot 1 can operate while the server is in standby power mode...

Page 21: ...o Twinax Cables for Each Network Card Ordered You may choose one or two twinax cables for each network card ordered The cables can be different lengths however you would normally order two cables of equal lengths to connect to the primary and redundant network switching equipment Caveats The twinax cables listed in Table 8 can be ordered only for the following PCIe cards UCSC PCIE CSC 02 Cisco VIC...

Page 22: ...s Caveats The SFP 10G SR optical module listed in Table 9 should be ordered only for the following PCIe cards as they do not come by default with any optical modules UCSC PCIE CSC 02 Cisco VIC 1225 Dual Port 10Gb SFP CNA UCSC PCIE BSFP Broadcom 57712 N2XX ABPCI02 Broadcom 57711 N2XX AEPCI01 Emulex OCe10102 F The DS SFP FC8G SW optical module listed in Table 9 should be ordered only for the followi...

Page 23: ...Cisco UCS C24 M3 High Density SFF Rack Mount Server CONFIGURING the SERVER 23 Figure 5 Network Card Connections ...

Page 24: ...rica CAB AC 250V 13A Power Cord NEMA L6 20 250V 20A plug IEC320 C13 receptacle North America CAB C13 CBN CABASY WIRE JUMPER CORD 27 L C13 C14 10A 250V CAB C13 C14 AC Power Cord recessed receptacle AC power cord 27 inches CAB C13 C14 2M CABASY WIRE JUMPER CORD PWR 2 Meter C13 C14 10A 250V SFS 250V 10A AR Power Cord SFS 250V 10A Argentina Cordset rating 10 A 250 V Length 8 2 ft 186570 Plug NEMA 6 15...

Page 25: ...ble Power Cords Product ID PID PID Description Images Plug Cordset rating 10 A 250 V 500 V MAX Length 2500mm 186580 Connector EL 701C EN 60320 C15 EL 210 BS 1363A 13 AMP fuse Cordset rating 10A 250V 2500 mm Plug EL 218 CCEE GB2009 186573 Connector EL 701 IEC60320 C13 Connector VSCC15 Cordset rating 10A 16 A 250 V Length 8 ft 2 in 2 5 m Plug M2511 186576 OVE Cordset rating 16A 250V 2500mm Plug EL 2...

Page 26: ... Power Cord 125VAC 13A NEMA 5 15 Plug North America Image not available CAB JPN 3PIN Power Cord 3PIN Japan Image not available Table 10 Available Power Cords Product ID PID PID Description Images Plug MP232 R Cordset rating 10 A 250 V Length 8 ft 2 in 2 5 m 186578 Connector IEC 60320 C15 Plug Cordset rating 10 A 250 V 500 V MAX Length 2500mm 186580 Connector EL 701C EN 60320 C15 EL 210 BS 1363A 13...

Page 27: ... making a power supply selection the UCS Power Calculator should be run to determine the right size power supply for your server configuration The UCS Power Calculator can be found at the following link https express salire com Go Cisco Cisco UCS Power Calculator aspx Caveats You cannot mix power supply types If you have two power supplies they must be identical either two 450 W or two 650 W power...

Page 28: ...management Use Table 12 to order a cable management arm For more information about the cable management arm see the Cisco UCS C24 M3 Installation and Service Guide at this URL http www cisco com en US docs unified_computing ucs c hw C24 install C24 pdf Table 12 Cable Management Arm Product ID PID PID Description UCSC CMA1 Cable Management Arm for C24 rack servers NOTE If you order and install a ca...

Page 29: ...on keys A TPM can also be used to store platform measurements that help ensure that the platform remains trustworthy Authentication ensuring that the platform can prove that it is what it claims to be and attestation a process helping to prove that a platform is trustworthy and has not been breached are necessary steps to ensure safer computing in all environments The TPM ordering information is l...

Page 30: ...a license dongle The 16 GB drive if ordered comes as a separate item in the shipping box and contains preloaded drivers and utilities You can move the 16 GB drive from one server to another in order to install the drivers and utilities onto multiple servers The USB drive ordering information is listed in Table 14 See Figure 6 on page 41 for the location of the internal 8 GB USB connector Table 14 ...

Page 31: ...et 4 Guest 3Yr Svcs Required RHEL 2S UG 1A RHEL 2 Socket U Guest 1Yr Svcs Required RHEL 2S UG 3A RHEL 2 Socket U Guest 3Yr Svcs Required RHEL Add Ons RHEL HA 2S 1A RHEL Option High Availability 2 Socket 1Yr Svcs Required RHEL RS 2S 1A RHEL Option Resilient w Ha 2 Socket 1 Yr Svcs Required RHEL SFS 2S 1A RHEL Option Scalable File System 2 Socket 1 Yr Svcs Required RHEL HA 2S 3A RHEL Option High Ava...

Page 32: ...t VMW VS5 ENT 2A VMware vSphere 5 Enterprise for 1 CPU 2 Yr Support VMW VS5 ENT 3A VMware vSphere 5 Enterprise for 1 CPU 3 Yr Support VMW VS5 ENT 4A VMware vSphere 5 Enterprise for 1 Processor 4 Year Support VMW VS5 ENT 5A VMware vSphere 5 Enterprise for 1 CPU 5 Yr Support VMW VS5 ENTP 1A VMware vSphere 5 Enterprise Plus for 1 Processor 1 Year Support Rqd VMW VS5 ENTP 2A VMware vSphere 5 Enterpris...

Page 33: ...ng system media listed in Table 16 Table 16 OS Media Product ID PID PID Description RHEL 6 RHEL 6 Recovery Media Only Multilingual SLES 11 SLES 11 media only multilingual MSWS 08R2 STHV RM Windows Svr 2008 R2 ST 1 4CPU 5CAL Media MSWS 08R2 ENHV RM Windows Svr 2008 R2 EN 1 8CPU 25CAL Media MSWS 08R2 DCHV RM Windows Svr 2008 R2 DC 1 8CPU 25CAL Media ...

Page 34: ...quired BMC AE 4C BladeLogic Advanced Edition 4 Cores Support Required BMC AE 6C BMC BladeLogic Advanced Edition 6 Cores Support Required BMC AE 8C BMC BladeLogic Advanced Edition 8 Cores Support Required BMC AE 10C BMC BladeLogic Advanced Edition 10 Cores Support Required BMC 002 BMC BladeLogic CM Physical Server BMC 012 BMC BPPM Per Server VMW VC5 STD 1A VMware vCenter 5 Standard for 1 Processor ...

Page 35: ...isco Unified Computing System warranty Cisco offers the Cisco Unified Computing Warranty Plus Service You can choose from several levels of advanced parts replacement coverage including onsite parts replacement in as little as two hours Warranty Plus provides remote access any time to Cisco support professionals who can determine if a return materials authorization RMA is required See Table 18 Uni...

Page 36: ...ive In exchange for a Cisco replacement drive you provide a signed Certificate of Destruction CoD confirming that the drive has been removed from the system listed is no longer in service and has been destroyed Sophisticated data recovery techniques have made classified proprietary and confidential information vulnerable even on malfunctioning disk drives The UCDR service enables you to retain you...

Page 37: ...already support by a UCS Support Service or SMARTnet service contract For further information Table 20 Drive Retention Service Options Service Description Service Program Name Service Level GSP Service Level Product ID PID UCS Mission Critical Support Service With Drive Retention UC CRIT DR UCMD7 24x7x4 Onsite CON UCMD7 C24M3S UCMD8 24x7x2 Onsite CON UCMD8 C24M3S UCS Support Service With Drive Ret...

Page 38: ... Management CEC site and Service Description or contact your Cisco account Manager For more service and support information see this URL http www cisco com en US services ps2961 ps10312 ps10321 Cisco_UC_Warranty_Support_DS pdf For a complete listing of available services for Cisco Unified Computing System see this URL http www cisco com en US products ps10312 serv_group_home html ...

Page 39: ... more information about the R42610 rack see RACKS page 47 Table 21 Racks and Rack Options Product ID PID PID Description RACK UCS1 Notes 1 Use these same base PIDs to order spare racks available only as next day replacements Cisco R42610 expansion rack no side panels RACK UCS21 Cisco R42610 standard rack w side panels RACK BLANK 001 Filler panels qty 12 1U plastic toolless RACK CBLMGT 001 Cable mg...

Page 40: ...ional power distribution unit PDU is available from Cisco for the C Series rack servers including theC24 M3 server This PDU is available in a zero rack unit RU style see Table 21 For more information about the PDU see PDUs page 49 Table 22 PDU Options Product ID PID PID Description RP208 30 2P U 2 Zero RU PDU ...

Page 41: ...through front panel 8 Internal USB 2 0 port on motherboard 2 Drive backplane 9 RTC battery on motherboard 3 SAS expander 10 PCIe riser 2 three half height slots 4 Fan modules 4 11 Trusted platform module socket on motherboard 5 DIMM slots on motherboard 12 12 Power supplies two hot swappable access through rear panel 285245 Port 1 Port 0 SYS FAN1 SYS FAN2 SYS FAN3 SYS FAN4 CPU 1 CPU 2 PCIe riser 1...

Page 42: ... to Bank 0 while A1 B1 and C1 belong to Bank 1 Figure 7 shows how banks and channels are physically laid out on the motherboard The DIMM slots on the top channels A B and C are associated with CPU 1 while the DIMM slots on the bottom channels D E and F are associated with CPU 2 Bank 0 slots blue are populated before Bank 1 slots black Figure 7 Physical Layout of CPU DIMM Channels and Banks 6 CPUs ...

Page 43: ...ls per CPU socket and 2 CPUs must be populated At 1 DPC and 2 DPC 1600 MHz DIMMS will run at 1600 MHz provided the CPU supports 1600 MHz DIMMs and 1333 MHz DIMMs will run at 1333 MHz When mixing DIMMs the following rules need to be followed When mixing DIMMs of different densities sizes populate DIMMs with the highest density first For example if you have to mix 16 GB with 8 GB DIMMs populate 16 G...

Page 44: ...ossibility of increasing total memory size in the system beyond 48 GB by going to 2 DPC while still maintaining memory speed at 1600 MHz If there is no plan to increase total memory size in the system beyond 48 GB then 12 x 4GB is more price effective at this time 3 x 4 GB 3 x 4 GB 3 x 4 GB 3 x 4 GB 12 3 x 8 GB 3 x 8 GB 6 72 GB 3 x 8 GB 3 x 4 GB 3 x 8 GB 3 x 4 GB 12 96 GB2 2 For 96 GB there are tw...

Page 45: ... GB 6 x 4 GB 6 24GB 6 x 4 GB 6 24GB 12 48 GB 3 x 8 GB 3 24 GB 3 x 8 GB 3 24 GB 6 48 GB 4 x 8 GB 4 32 GB 4 x 8 GB 4 32 GB 8 64 GB 2 x 16 GB 2 32 GB 2 x 16 GB 2 32 GB 4 64 GB 3 x 8 GB 3 x 4 GB1 Notes 1 UCS MR 1X082RY A UCS MR 1X041RY A 6 36 GB 3 x 8 GB 3 x 4 GB2 2 UCS MR 1X082RY A UCS MR 1X041RY A 6 36 GB 12 72 GB 5 x 8 GB 5 40 GB 5 x 8 GB 5 40 GB 10 80 GB 6 x 8 GB 6 48 GB 6 x 8 GB 6 48 GB 12 96 GB ...

Page 46: ...ntical manufacturer type speed and size Low voltage DIMMs and standard voltage DIMMs can be mixed in the same server Note that this causes the system BIOS to default to standard voltage operation Performance Mode That is the server cannot operate in Power Saving Mode unless all DIMMs are low voltage DIMMs CPUs that have a maximum memory frequency less than 1333 MHz support low voltage DIMMs operat...

Page 47: ...s Parameter Standard Rack Expansion Rack Dimensions H x W x D 78 74 x 24 x 43 38 in 2000 x 610 x 1102 mm 78 74 x 23 58 x 43 38 in 2000 x 599 x 1102 mm Dimensions H x W x D with packaging 89 x 33 x 47 in 2261 x 838 x 1194 mm 89 x 33 x 47 in 2261 x 838 x 1194 mm Distance from front mounting rail to rear mounting rail 29 2 in 741 mm 29 2 in 741 mm Weight 299 83 lb 136 kg 231 49 lb 105 kg Weight with ...

Page 48: ...Cisco UCS C24 M3 High Density SFF Rack Mount Server 48 SUPPLEMENTAL MATERIAL Figure 8 Cisco R42610 Rack Front view door closed Front view door open Front view door removed ...

Page 49: ...rack you can replace up to two dozen input power cords with just one The fixed input cord connects to the power source from overhead or under floor distribution Your IT equipment is then powered by PDU outlets in the rack using short easy to manage power cords The C series severs accept the zero rack unit 0RU PDU See Figure 9 Figure 9 Zero Rack Unit PDU PID RP208 30 2P U 2 Cisco RP Series PDU mode...

Page 50: ...herboard USB Port The C24 M3 SFF motherboard has one general purpose USB socket as shown in Figure 10 Figure 10 Motherboard USB Port 1 USB 2 0 port on motherboard 285245 Port 1 Port 0 SYS FAN1 SYS FAN2 SYS FAN3 SYS FAN4 CPU 1 CPU 2 PCIe riser 1 PCIe riser 2 PSU 1 bottom PSU 2 top 1 ...

Page 51: ...status LED 2 Hard drive activity LED 7 System status LED 3 Network link activity LED 8 Identification button LED 4 Power supply status LED 9 Power button power status LED 5 Temperature status LED Table 26 Front Panel LEDs LED LED State Meaning Hard Drive Fault Off The hard drive is operating properly On amber The hard drive has failed Blinking amber The hard drive is rebuilding 285243 HDD 01 HDD 0...

Page 52: ...re temperature sensors exceeded a critical threshold Fan Status Off Undefined On green Fans are operating and no error condition has been detected On amber Fans are in a degraded operational state indicating that one of the fans has a fault Blinking amber Critical fault state indicating that two or more fans have a fault System Status Off Undefined On green Server is in normal operating condition ...

Page 53: ...off On amber Server power is soft off power is supplied only to the CIMC and some motherboard functions On green Card power is on 1 Power supply fault LED 5 10 100 1000 Ethernet dedicated management link status LED 2 Power supply AC OK LED 6 10 100 1000 Ethernet dedicated management link speed LED 3 1 GbE link speed LED 7 Identification button LED 4 1 GbE link status LED Table 26 Front Panel LEDs ...

Page 54: ...ondition Power Supply AC Off There is no AC power to the power supply Blinking green AC power OK DC output not enabled On green AC power OK DC outputs OK 1 GbE Link Speed Off Link Speed 10 MbpS On amber Link Speed 100 MbpS On green Link Speed 1 GbpS 1 GbE Link Status Off No Link On green Link is active Blinking green Traffic is present on the active link 10 100 1000 Base T Link Speed Off Link Spee...

Page 55: ...3 mm Weight Maximum 24 HDDs 2 CPUs 12 DIMMs 2 power supplies 47 18 lbs 21 4 kg Bare 0 HDD 0 CPU 0 DIMM no power supply 34 5 lbs 15 65 kg Table 29 UCS C24 M3 SFF 450 W Power Supply Specifications Description Specification AC input voltage 90 to 264 VAC self ranging 100 to 120 VAC nominal 200 to 240 VAC nominal AC input frequency Range 47 to 63 Hz single phase 50 to 60 Hz nominal Maximum AC input cu...

Page 56: ...ower inlet Table 30 UCS C24 M3 SFF 650 W Power Supply Specifications Description Specification AC input voltage 90 to 264 VAC self ranging 100 to 120 VAC nominal 200 to 240 VAC nominal AC input frequency Range 47 to 63 Hz single phase 50 to 60 Hz nominal Maximum AC input current 7 6 A maximum at 100 VAC 3 65 A maximum at 208 VAC Maximum AC inrush current 11 A peak 35 C 208 VAC Maximum output power...

Page 57: ...41 to 104 F 5 to 40 C derate the maximum temperature by 1 C per every 305m of altitude above sea level Temperature nonoperating 40 to 149 F 40 to 65 C Humidity RH nonoperating non condensing 10 to 90 Altitude operating 0 to 3 000 m 0 to 10 000 ft Altitude nonoperating 0 to 12 192 m 0 to 40 000 ft Sound Power level Measure A weighted per ISO7779 LWAd Bels Operation at 73 F 23 C 5 9 Sound Pressure l...

Page 58: ...tory Compliance Products should comply with CE Markings per directives 2004 108 EC and 2006 95 EC Safety UL 60950 1 Second Edition CAN CSA C22 2 No 60950 1 Second Edition EN 60950 1 Second Edition IEC 60950 1 Second Edition AS NZS 60950 1 GB4943 2001 EMC Emissions 47CFR Part 15 CFR 47 Class A AS NZS CISPR22 Class A CISPR22 Class A EN55022 Class A ICES003 Class A VCCI Class A EN61000 3 2 EN61000 3 ...

Reviews: