Spec Sheet

This product has been 
discontinued

Cisco UCS C210 M2

General-Purpose 

 

Rack-Mount Server

Summary of Contents for UCS C210 M2

Page 1: ...SCO SYSTEMS PUBLICATION HISTORY 170 WEST TASMAN DR SAN JOSE CA 95134 REV A 13 APRIL 25 2014 WWW CISCO COM Spec Sheet This product has been discontinued Cisco UCS C210 M2 General Purpose Rack Mount Server ...

Page 2: ...RDS 30 STEP 12 ORDER TOOL LESS OPTIONAL RAIL KIT 33 STEP 13 ORDER OPTIONAL CABLE MANAGEMENT ARM 34 STEP 14 ORDER A TRUSTED PLATFORM MODULE 35 STEP 15 CHOOSE OPERATING SYSTEM AND VALUE ADDED SOFTWARE 36 STEP 16 CHOOSE OPERATING SYSTEM MEDIA KIT 39 STEP 17 CHOOSE SERVICE and SUPPORT LEVEL 40 OPTIONAL STEP ORDER RACK s 44 OPTIONAL STEP ORDER PDU 45 SUPPLEMENTAL MATERIAL 46 CHASSIS 46 CPUs and DIMMs 4...

Page 3: ...The UCS C210 M2 server shown in Figure 1 extends the capabilities of the Cisco Unified Computing System The server uses Intel s latest Xeon 5600 Series multicore processors with 12 DIMM slots 5 PCIe slots embedded dual port gigabit Ethernet controller and up to 16 2 5 inch SAS SATA hot swappable hard disk drives HDDs or solid state drives SSDs Figure 1 Cisco UCS C210 M2 High Density Rack Server Fr...

Page 4: ...on regarding the KVM cable connection see KVM CABLE on page 57 1 Locator LED Locator Button 6 Memory fault LED 2 Network Activity LED 7 Power supply fault LED 3 System fault LED 8 Console connector with supplied KVM cable provides DB15 video DB9 serial and two USB 2 0 connectors 4 Power button Power status LED 9 DVD RW drive with dual layer DL media support optional 5 CPU fault LED 10 Hard drives ...

Page 5: ...3 shows the external features of the rear panel Figure 3 Chassis Rear View 1 Power supply up to 2 5 Serial connector DB9 2 USB 2 0 connectors 2 6 10 100 1000 Megabit Ethernet ports 2 3 10 100 Ethernet management port RJ 45 7 Standard profile PCIe card slots five total 4 Video connector DB15 VGA ...

Page 6: ...f length x8 lane with a x16 connector Storage controller One of the following An onboard SATA RAID 0 1 controller integrated on motherboard Intel ICH10R that can control up to four SATA drives only or An optional RAID mezzanine card LSI 1064E 4 port controller mezzanine card RAID levels 0 1 or 1E for up to 4 internal SAS or SATA drives with the factory default SAS Extender or the optional SAS Expa...

Page 7: ...tor Front Panel Optional DVD RW optical drive with dual layer DL media support Power subsystem Up to two 650 W power supplies N 1 or nonredundant configuration options Fans Chassis Three 80 mm redundant fans Power supply Each power supply is equipped with a fan Integrated management processor Cisco Integrated Management Controller CIMC with integrated video KVM redirection Security Intelligence Op...

Page 8: ...TEP 7 CHOOSE PCIe OPTION CARD S page 23 STEP 8 ORDER OPTIONAL NETWORK CARD ACCESSORIES page 25 STEP 9 CHOOSE OPTIONAL DVD RW DRIVE page 28 STEP 10 ORDER OPTIONAL REDUNDANT POWER SUPPLY page 29 STEP 11 CHOOSE AC POWER CORDS page 30 STEP 12 ORDER TOOL LESS OPTIONAL RAIL KIT page 33 STEP 13 ORDER OPTIONAL CABLE MANAGEMENT ARM page 34 STEP 14 ORDER A TRUSTED PLATFORM MODULE page 35 STEP 15 CHOOSE OPER...

Page 9: ...Includes one power supply Does not include CPU memory hard disk drives HDDs Solid State Drives SSDs plug in PCIe cards or optional DVD RW drive Table 2 PID of the Base C210 M2 Rack Server Product ID PID Description R210 2121605W UCS C210 M2 Srvr w 1PSU w o CPU mem HDD DVD or PCIe card NOTE Use the steps on the following pages to configure the server with the components that you want to include ...

Page 10: ... and DIMM clock For example Selecting lower speed DIMMs If you use an X5650 CPU which can support up to 1333 MHz DIMMs with 1066 MHz DIMMs the DIMMs will be clocked at the lower speed of 1066 MHz Selecting higher speed DIMMs If you use 1333 MHz DIMMs with an E5620 CPU which can support up to 1066 MHz DIMMs the DIMMS will be clocked at the lower speed of 1066 MHz A01 X0117 X5675 3 06 95 12 6 6 4 GT...

Page 11: ...lock and DIMM clock For example Selecting lower speed DIMMs if you use an X5570 CPU which can support up to 1333 MHz DIMMs with 1066 MHz DIMMs the DIMMs will be clocked at the lower speed of 1066 MHz Selecting higher speed DIMMs If you use 1333 MHz DIMMs with an E5506 CPU which can support up to 800 MHz DIMMs the DIMMS will be clocked at the lower speed of 800 MHz N20 X00001 X5570 2 93 95 8 4 6 4 ...

Page 12: ... Configurations Choose two identical CPUs from any one of the rows of Table 3 on page 10 or Table 4 on page 11 Caveats You can select either one processor or two identical processors For optimal performance select DIMMs with the highest clock speed for a given processor see Table 5 on page 14 If you select DIMMs whose speeds are lower or higher than that shown in the tables suboptimal performance ...

Page 13: ... speed 800 MHz 1066 MHz or 1333 MHz Ranks per DIMM 1 2 or 4 Operational voltage single voltage 1 5 V or dual voltage 1 35 V 1 5 V Registered DDR3 ECC registered DIMMs RDIMMs supporting Intel SDDC Memory is organized with three memory channels per CPU with up to two DIMMs per channel DPC as shown in Figure 4 Figure 4 C210 M2 Memory Organization ...

Page 14: ...ect data due to an uncorrectable memory error the system automatically retrieves the data from the other channel A transient or soft error in one channel does not affect the mirrored data and operation continues unless there is a simultaneous error in exactly the same location on a DIMM and its mirrored DIMM Memory mirroring reduces the amount of memory available to the operating system by 50 beca...

Page 15: ... 1066 MHz Performance Mode at a maximum speed of 1333 MHz If you mix both types of DIMMs in your configuration the server forces all DIMMs to operate in Performance Mode Memory mirroring If you choose the Memory RAS option be aware that it is available only with an even number of memory channels For example if you choose six DIMMs and select RAS Number of DIMMs DIMM Placement Channels C and F are ...

Page 16: ...ust be identical If you only have two DIMMs they need to be the same PID because you have one DIMM on each of two buses If you have four DIMMs in a 2 CPU system for example you can have two 4 GB and two 8 GB DIMMs One 4 GB 8 GB DIMM pair would located on Channel A of CPU 1 and one 4 GB 8 GB DIMM pair would be located on Channel D of CPU 2 If you have four DIMMs in a 1 CPU system for example you ca...

Page 17: ...on the 9280 4i4e and 9261 8i but are not factory configurable Choose RAID Options Choose one RAID controller one RAID configuration option and if desired the battery backup option listed in Table 6 Table 6 Available RAID Options Product ID PID PID Description RAID Controllers R2X0 ML002 LSI 1064E 4 port SAS 3 0G RAID Mezzanine Card Installed on the mezzanine connector inside the UCS C210 M2 server...

Page 18: ...ption not available with mezzanine card R2XX LBBU2 Battery Backup RAID Configuration note Mezzanine card supports only RAID 0 1 and 1E R2XX RAID0 Factory pre configured RAID striping option Enable RAID 0 Setting Requires a minimum of 1 hard drive R2XX RAID1 Factory pre configured RAID mirroring option Enable RAID 1 Setting Requires exactly 2 drives with same size speed capacity R2XX RAID5 Factory ...

Page 19: ...slot 4 Refer to Figure 3 on page 5 for PCIe slot numbering If you choose the mezzanine RAID controller card you will still have all five PCIe slots available for adding optional cards The two optional plug in RAID controllers are each half height PCIe cards If you choose one of these optional cards you will still have four slots available for adding optional PCIe cards You can choose only one RAID...

Page 20: ...10 M2 server chassis The SAS Extender supports up to eight disk drives The SAS Extender option is not field upgradeable to a SAS Expander Both the SAS Extender and SAS Expander however are field replaceable You can replace an extender or expander only with the same type of card If desired select the SAS Expander listed in Table 7 For more information about the SAS Expander and SAS Extender see SAS...

Page 21: ...ed HDDs and SSDs Product ID PID PID Description Drive Type Capacity HDDs A03 D146GC2 146GB 6 Gb SAS 15K RPM SFF SAS 146 GB A03 D300GA2 300 GB 6 Gb SAS 10K RPM SFF HDD SAS 300 GB UCS HDD300GI2F105 300GB 6Gb SAS 15K RPM SFF HDD SAS 300 GB A03 D500GC3 500 GB 6 Gb SATA 7 2K RPM SFF SATA 500 GB A03 D600GA2 600 GB 6 Gb SAS 10K RPM SFF HDD SAS 600 GB UCS HDD900GI2F106 900GB 6Gb SAS 10K RPM SFF HDD SAS 90...

Page 22: ...r You cannot mix HDD and SSD drive types or SAS and SATA drives 4 LSI MegaRAID SAS 9261 8i RAID controller Select up to eight internal SAS or SATA drives listed in Table 8 You can mix SAS and SATA drives but you cannot mix HDD and SSD drive types If you order the optional SAS Expander the controller can support up to 16 internal drives Caveats If the integrated RAID controller on the server mother...

Page 23: ...CSI Half Network Interface Cards NICs N2XX ABPCI02 Broadcom 57711 Dual Port 10GbE NIC w TOE iSCSI Half N2XX ABPCI03 M3 Broadcom 5709 Quad Port 1Gb w TOE iSCSI for M3 Servers Half N2XX ABPCI01 M3 Broadcom 5709 Dual Port 1Gb w TOE iSCSI for M3 Servers Half N2XX AQPCI01 Qlogic QLE 8152 CNA 2port 10Gb SFP Copper Half N2XX AIPCI02 Intel Quad port GbE Controller E1G44ETG1P20 Half N2XX AIPCI01 Intel X520...

Page 24: ...1E Virtual Interface Card 2 port 10Gbp card may be installed and it must be installed in slot 1 or slot 2 Note however that if the server is running UCSM only slot 1 is supported for the VIC card See Figure 3 on page 5 for slot numbering All cards will fit in any slot The MegaRAID cards LSI MegaRAID SAS 9280 4i4e or LSI MegaRAID SAS 9261 8i must be installed in PCIe slot 4 Refer to Figure 3 on pag...

Page 25: ... may choose one or two twinax cables for each network card ordered The cables can be different lengths however you would normally order two cables of equal lengths to connect to the primary and redundant network switching equipment Caveats The twinax cables listed in Table 10 can be ordered only for the following PCIe cards N2XX ACPCI01 Cisco UCS P81E Virtual Interface Card 2 port 10Gbps UCS PCIE ...

Page 26: ...ats The SFP 10G SR optical module listed in Table 11 should be ordered only for the following PCIe cards as they do not come by default with any optical modules N2XX ACPCI01 Cisco UCS P81E Virtual Interface Card 2 port 10Gbps UCSC PCIE BSFP Broadcom 57712 N2XX ABPCI02 Broadcom 57711 N2XX AEPCI01 Emulex OCe10102 F The DS SFP FC8G SW optical module listed in Table 11 should be ordered only for the f...

Page 27: ...Cisco UCS C210 M2 General Purpose Rack Mount Server CONFIGURING the SERVER 27 Figure 5 Network Card Connections ...

Page 28: ...SERVER STEP 9 CHOOSE OPTIONAL DVD RW DRIVE An optional DVD RW optical drive with dual layer DL media support may be ordered The drive is listed in Table 12 Table 12 Available DVD RW Drive Product ID PID PID Description R210 ODVDRW DVD RW Drive for UCS C210 M2 Rack Servers ...

Page 29: ...rver can accommodate two power supplies Only one power supply is required One 650 W power supply ships with the base server chassis You can order an optional redundant power supply listed in Table 13s Table 13 Redundant Power Supply Product ID PID PID Description R2X0 PSU2 650W SB 650 W power supply w added 5A Standby for UCS C200 or C210 ...

Page 30: ...V 13A Power Cord NEMA L6 20 250V 20A plug IEC320 C13 receptacle North America CAB C13 C14 JMPR Power Cord recessed receptacle AC power cord 27 SFS 250V 10A AR Power Cord SFS 250V 10A Argentina CAB 9K10A AU Power Cord 250VAC 10A 3112 Plug Australia Cordset rating 10 A 250 V Length 8 2 ft 186570 Plug NEMA 6 15P Connector IEC60320 C13 Cordset rating 13A 250V 6 6 feet 79 2m Plug EL312MoldedTwistlock N...

Page 31: ...PID Description Images Cordset rating 10A 250V 2500 mm Plug EL 218 CCEE GB2009 186573 Connector EL 701 IEC60320 C13 Connector VSCC15 Cordset rating 10A 16 A 250 V Length 8 ft 2 in 2 5 m Plug M2511 186576 OVE Cordset rating 16A 250V 2500mm Plug EL 208 187490 Connector EL 701 Cordset rating 10A 250V 500V MAX 2500 mm Plug EL 212 SI 32 186574 Connector EL 701B IEC60320 C13 EL 212 16A 250V Plug I 3G CE...

Page 32: ...rver 32 CONFIGURING the SERVER CAB 9K12A NA Power Cord 125VAC 13A NEMA 5 15 Plug North America Image not available CAB JPN 3PIN Power Cord 3PIN Japan Image not available Table 14 Available Power Cords continued Product ID PID PID Description Images ...

Page 33: ...NAL STEP ORDER RACK s on page 44 for information about racks and rack equipment Table 15 Rail Kit Product ID PID PID Description R2XX G31032RAIL Rail Kit for UCS 200 210 Rack Servers NOTE This third generation rail kit works in racks with square holes or 10 32 round holes and is shorter than the previous generation rail kit The new R2XX G31032RAIL measures 23 5 inches to 36 inches in length By com...

Page 34: ...nd is used for cable management You can order the cable management arm listed in Table 16 For more information about the cable management arm see the Cisco UCS C210 Installation and Service Guide at this URL http www cisco com en US docs unified_computing ucs c hw C210M1 install C210M1 html Table 16 Cable Management Arm Product ID PID PID Description R2XX CMAG3 1032 Cable Mgmt Arm for R2XX G31032R...

Page 35: ...tion keys A TPM can also be used to store platform measurements that help ensure that the platform remains trustworthy Authentication ensuring that the platform can prove that it is what it claims to be and attestation a process helping to prove that a platform is trustworthy and has not been breached are necessary steps to ensure safer computing in all environments The TPM ordering information is...

Page 36: ...x Enterprise Srvr 1 2 CPU 1 Phys 5yr Support Reqd SLES SVR 2S UG 1A SUSE Linux Enterprise Svr 1 2 CPU Unl Vrt 1yr Support Reqd SLES SVR 2S UG 3A SUSE Linux Enterprise Svr 1 2 CPU Unl Vrt 3yr Support Reqd SLES SVR 2S UG 5A SUSE Linux Enterprise Svr 1 2 CPU Unl Vrt 5yr Support Reqd SLES SHA 2S 1A SUSE Linux High Availability Ext 1 2 CPU 1yr Support Reqd SLES SHA 2S 3A SUSE Linux High Availability Ex...

Page 37: ... Server BMC SE 4C BMC BladeLogic Standard Edition 4 Cores Support Required BMC SE 6C BMC BladeLogic Standard Edition 6 Cores Support Required BMC SE 8C BMC BladeLogic Standard Edition 8 Cores Support Required BMC SE 10C BMC BladeLogic Standard Edition 10 Cores Support Required BMC AE 4C BMC BladeLogic Advanced Edition 4 Cores Support Required BMC AE 6C BMC BladeLogic Advanced Edition 6 Cores Suppo...

Page 38: ...are vSphere 5 Enterprise for 1 CPU 5 Yr Support Rqd VMW VS5 ENTP 1A VMware vSphere 5 Enterprise Plus for 1 Processor 1 Year Support Rqd VMW VS5 ENTP 2A VMware vSphere 5 Enterprise Plus for 1 CPU 2 Yr Support Rqd VMW VS5 ENTP 3A VMware vSphere 5 Enterprise Plus for 1 Processor 3 Year Support Rqd VMW VS5 ENTP 4A VMware vSphere 5 Enterprise Plus for 1 Processor 4 Year Support Rqd VMW VS5 ENTP 5A VMwa...

Page 39: ...scription RHEL 6 RHEL 6 Recovery Media Only Multilingual SLES 11 SLES 11 media only multilingual MSWS 08R2 STHV RM Windows Svr 2008 R2 ST 1 4CPU 5CAL Media MSWS 08RS ENHV RM Windows Svr 2008 R2 EN 1 8CPU 25CAL Media MSWS 08R2 DCHV RM Windows Svr 2008 R2 DC 1 8CPU 25CAL Media MSWS 12 ST2S RM Windows Server 2012 Standard 2 CPU 2 VMs Recovery Media MSWS 12 DC2S RM Windows Server 2012 Datacenter 2 CPU...

Page 40: ...threatens business continuity the TAM provides crisis management leadership and your IT staff receives expedited access to Cisco s Technical Assistance Center TAC Please note This service has qualification criteria Your company must have 1 2M of UCS equipment 200 blades and a single location to qualify for this service level Choose the desired service listed in Table 20 Unified Computing Support S...

Page 41: ...f a return materials authorization RMA is required You can choose a service listed in Table 22 Table 21 UCS Computing Support Service Product ID PID On Site Description CON UCS1 R210W No UC Support 8X5XNBD CON UCS2 R210W No UC Support 8X5X4 CON UCS3 R210W No UC Support 24x7x4 CON UCS4 R210W No UC Support 24x7x2 CON UCS5 R210W Yes UC Support 8X5XNBD CON UCS6 R210W Yes UC Support 8X5X4 CON UCS7 R210...

Page 42: ...any potential liabilities This service also enables you to comply with regulatory local and federal requirements If your company has a need to control confidential classified sensitive or proprietary data you might want to consider one of the Drive Retention Services listed in Table 23 NOTE Cisco does not offer a certified drive destruction service as part of this service Table 23 Drive Retention ...

Page 43: ...ee this URL http www cisco com en US products ps10312 serv_group_home html UCS Warranty Plus With Drive Retention UC PLUS DR UCWD2 8x5x4 CON UCWD2 R210WSFF UCWD3 24x7x4 CON UCWD3 R210WSFF UCWD4 24x7x2 CON UCWD4 R210WSFF UCWD5 8x5xNBD Onsite CON UCWD5 R210WSFF UCWD6 8x5x4 Onsite CON UCWD6 R210WSFF UCWD7 24x7x4 Onsite CON UCWD7 R210WSFF UCWD8 24x7x2 Onsite CON UCWD8 R210WSFF Table 23 Drive Retention...

Page 44: ...e information about the R42610 rack see RACKS on page 53 Table 24 Racks and Rack Options Product ID PID PID Description RACK UCS1 Notes 1 Use these same base PIDs to order spare racks available only as next day replacements Cisco R42610 expansion rack no side panels RACK UCS21 Cisco R42610 standard rack w side panels RACK BLANK 001 Filler panels qty 12 1U plastic toolless RACK CBLMGT 001 Cable mgt...

Page 45: ...nal power distribution unit PDU is available from Cisco for the C Series rack servers including theC210 M2 server This PDU is available in a zero rack unit RU style see Table 24 For more information about the PDU see PDUs on page 55 Table 25 PDU Options Product ID PID PID Description RP208 30 2P U 2 Zero RU PDU ...

Page 46: ...2 General Purpose Rack Mount Server 46 SUPPLEMENTAL MATERIAL SUPPLEMENTAL MATERIAL CHASSIS An internal view of the C210 M2 chassis with the top cover removed is shown in Figure 6 Figure 6 C210 M2 With Top Cover Removed ...

Page 47: ...Bank 2 Figure 7 shows how banks and channels are physically laid out on the motherboard The DIMM slots on the right channels A B and C are associated with CPU1 while the DIMM slots on the left channels D E and F are associated with CPU2 The Bank 1 blue DIMM slots are always located farther away from a CPU than the corresponding Bank 2 black slots Bank 1 slots are populated before Bank 2 slots If o...

Page 48: ...ank first Low voltage 1 35 V DIMM and standard voltage DIMM 1 5 V can be mixed in the same server Note that this causes the system BIOS to default to standard voltage operation Performance Mode See Low Voltage DIMM Considerations Low Voltage DIMM Considerations The C210 M2 server can be ordered with low voltage 1 35 V DIMMs or standard voltage 1 5 V DIMMs Note the following considerations Low volt...

Page 49: ...32 GB 2 CPUs 1 x 16 GB 1 x 16 GB 1066 MHz 2 2 x 8 GB 2 x 8 GB 1333 MHz 4 2 x 4 GB 2 x 4 GB 2 x 4 GB 2 x 4 GB 1333 MHz 8 24 GB 1 CPU 48 GB 2 CPUs 3 x 8 GB 3 x 8 GB 1333 MHz 61 3 x 4 GB 3 x 4 GB 3 x 4 GB 3 x 4 GB 1333 MHz 121 32 GB 1 CPU 64 GB 2 CPUs 2 x 16 GB 2 x 16 GB 1066 MHz 4 2 x 8 GB 2 x 8 GB 2 x 8 GB 2 x 8 GB 1333 MHz 8 36 GB 1 CPU 72 GB 2 CPUs 3 x 8 GB 3 x 4 GB 3 x 8 GB 3 x 4 GB 1333 MHz 121...

Page 50: ...Purpose Rack Mount Server 50 SUPPLEMENTAL MATERIAL Configuration Samples The following figures show examples of how DIMMs are populated for 1 CPU and 2 CPU systems Figure 8 Example of 24 GB DIMM Memory Combinations with One CPU ...

Page 51: ...Cisco UCS C210 M2 General Purpose Rack Mount Server SUPPLEMENTAL MATERIAL 51 Figure 9 Example of 96 GB DIMM Memory Combinations with Two CPUs ...

Page 52: ... controller the LSI 1064E mezzanine card or the LSI MegaRAID SAS 9280 4i4e and up to 8 drives when using the LSI MegaRAID SAS 9261 8i MegaRAID card SAS Expander The SAS expander see Figure 11 may be optionally ordered for the C210 M2 server Figure 11 SAS Expander The SAS Expander has two mini SAS SFF 8087 cable connectors One connector provides connection for up to 16 drives and the second connect...

Page 53: ...ns Parameter Standard Rack Expansion Rack Dimensions H x W x D 78 74 x 24 x 43 38 in 2000 x 610 x 1102 mm 78 74 x 23 58 x 43 38 in 2000 x 599 x 1102 mm Dimensions H x W x D with packaging 89 x 33 x 47 in 2261 x 838 x 1194 mm 89 x 33 x 47 in 2261 x 838 x 1194 mm Distance from front mounting rail to rear mounting rail 29 2 in 741 mm 29 2 in 741 mm Weight 299 83 lb 136 kg 231 49 lb 105 kg Weight with...

Page 54: ...Cisco UCS C210 M2 General Purpose Rack Mount Server 54 SUPPLEMENTAL MATERIAL Figure 12 Cisco R42610 Rack Front view door closed Front view door open Front view door removed ...

Page 55: ...ack you can replace up to two dozen input power cords with just one The fixed input cord connects to the power source from overhead or under floor distribution Your IT equipment is then powered by PDU outlets in the rack using short easy to manage power cords The C series severs accept the zero rack unit 0RU PDU See Figure 13 Figure 13 Zero Rack Unit PDU PID RP208 30 2P U 2 Cisco RP Series PDU mod...

Page 56: ...0 M2 General Purpose Rack Mount Server 56 SUPPLEMENTAL MATERIAL POWER SUPPLIES The C210 M2 can accommodate one or two 650 W power supplies A typical power supply is shown in Figure 14 Figure 14 C210 M2 Power Supply ...

Page 57: ... for a keyboard and mouse With this cable you can create a direct connection to the operating system and the BIOS running on the server The KVM cable ordering information is listed in Table 28 Figure 15 KVM Cable Table 28 KVM Cable Product ID PID PID Description 37 1016 01 KVM Cable 1 Connector to server front panel 3 VGA connector for a monitor 2 DB 9 serial connector 4 Two port USB connector for...

Page 58: ...co UCS C210 M2 General Purpose Rack Mount Server 58 SUPPLEMENTAL MATERIAL Motherboard USB Port The C210 M2 motherboard has a general purpose USB socket as shown in Figure 16 Figure 16 Motherboard USB Port ...

Page 59: ...3 45 in 8 76 cm Width 17 39 in 44 17 cm Depth 28 35 in 72 01 cm Front Clearance 3 in 7 62 cm Side Clearance 1 in 2 54 cm Rear Clearance 6 in 15 24 cm Weight 50 70 lbs 23 kg Table 30 UCS C210 M2 Power Specifications Description Specification AC input voltage 100 to 120 VAC nominal 200 to 240 VAC nominal Range 90 to 264 VAC AC input frequency 50 to 60 Hz nominal Range 47 to 63 Hz Maximum AC input cu...

Page 60: ...cs_power_calculator As an example using the calculator we can determine the approximate power for the following C210 M2 server configuration Voltage 115 VAC Power Supplies 2 Processors 2 CPUs Intel Xeon 2 93 GHz X5670 Memory DIMMs 6 x 16 GB Disk Drives 16 x 1 TB PCIe Cards 4 PCIe RAID Card 1 The resulting power calculations are Idle Power 263 W 50 Load Power 419 W Max Power 574 W NOTE AC input con...

Page 61: ...m Humidity nonoperating 5 to 93 noncondensing Vibration nonoperating 2 2 Grms 10 minutes per axis on each of the three axes Shock operating Half sine 2 G 11 ms pulse 100 pulses in each direction on each of the three axes Shock nonoperating Trapezoidal 25 G two drops on each of six faces Velocity 175 inches per second on bottom face drop Velocity 90 inches per second on the other five faces Electro...

Page 62: ...tory Compliance Products should comply with CE Markings per directives 2004 108 EC and 2006 95 EC Safety UL 60950 1 Second Edition CAN CSA C22 2 No 60950 1 Second Edition EN 60950 1 Second Edition IEC 60950 1 Second Edition AS NZS 60950 1 GB4943 2001 EMC Emissions 47CFR Part 15 CFR 47 Class A AS NZS CISPR22 Class A CISPR22 Class A EN55022 Class A ICES003 Class A VCCI Class A EN61000 3 2 EN61000 3 ...