Cisco UCS B420 M4 Blade Server
SUPPLEMENTAL MATERIAL
45
Network Connectivity
This section shows how the supported adapter card configurations for the B420 M4 connect to the Fabric
Extender modules in the 5108 blade server chassis.
There are three configurable adapter slots on the B420 M4. One slot supports only the VIC 1340/1240
adapter, and two additional slots accommodate Cisco adapters, as well as Cisco UCS Storage Accelerator
adapters.
and
show supported adapter configurations. You must
install at least one VIC adapter in one of the three adapter slots.
Maximum bandwidth is a function of the Fabric Extender, the adapter, and the adapter slot, as shown in
shows the configuration for maximum bandwidth, where the following ports are routed to 8-port
Fabric Extender Modules A and B inside the 5108 blade server chassis:
■
4 x 10 Gb KR ports from the VIC 1340/1240 adapter
■
4 x 10 Gb KR ports from the Port Expander
■
8 x 10 Gb KR ports from the VIC 1380/1280 adapter
■
4 x 10 Gb from a Cisco Storage Accelerator when placed in adapter slot 2, similar to the
Cisco UCS Port Expander Card for VIC. Requires UCSM 2.2(4b) or later.
The resulting aggregate bandwidth is 160 Gb (80 Gb to each Fabric Extender).
Table 30
Maximum Bandwidth Using Dual Fabric Extenders (FEXs)
FEX Model
Maximum
Bandwidth
Using Dual
FEXs
Example Configuration to Achieve Maximum Bandwidth
2304/2208XP
160 Gb
Adapter 1 = VIC 1340/1240 (40 Gb)
Adapter 2 = Port Expander (40 Gb)
Adapter 3 = VIC 1380/1280 (80 Gb)
See
2204XP
80 Gb
Adapter 1 = VIC 1340/1240 (20 Gb)
Adapter 2 = Port Expander (20 Gb)
Adapter 3 = VIC 1380/1280 (40 Gb)
See
NOTE:
, note that CPU4 controls adapter slot 2. In the case where a
Port Expander is installed in this slot, CPU4 is not needed. However, in the case
where a Storage Accelerator is installed in the slot, CPU4 must be installed.