Verify your settings

We strongly recommend that you verify the settings by inspecting the System 

Information list.
You do this by accessing the System Information in the same way as you did when 

you verified you IP address setting.

Go to System Information to verify the settings:

1. 

Navigate to 

Settings > System Information

2. 

Verify the previous configurations. For example, if you successfully registered 

to a SIP server the 

Status

 will show 

Registered

. If the registration failed the 

Status

 will show

 Not registered

.

3. 

Press Home ( 

 ) to exit.

5

Add the system to the network

Your service provider should have provided you with the information you need 

to get on-line. 
For H.323 type of communication, this will include such things as system 

name, H.323 alias, gatekeeper address, etc. For SIP type of communication, 

similar type of information will be supplied. 
For networks administrated through TMS (TANDBERG Management Suite), 

your TMS administrator will be able to assist you when configuring.

The H.323 and SIP settings are configured from the Advanced 
configurations menu:

1. 

Navigate to 

Settings > Advanced > Advanced Configuration 

and select

 

H323 

or

 SIP

2. 

Expand the items in need of modification and enter the information 

supplied by your service provider.

7

Set the time and date

Verify the date and time to see if the time zone settings need to be adjusted. 

The date and time is located in the upper right corner on screen.

Go to the Time settings to set the date and time:

1. 

Navigate to 

Settings > Date and time 

•  If you configure 

Set date and time 

to 

Auto:

•  Select the GMT time zone from the list and a select format for the 

date and time. 

•  If you configure 

Set date and time 

to 

Manual:

•  Set the date, month, year, time and select a format for the date and 

time. 

2. 

Press 

Save

 to save the changes, or 

Cancel

 to leave without saving.

8

Set the administrator settings menu password

By default the administrator password is blank.

NOTE! 

It is highly recommended to define a password to access the administrator 

settings menus. Changing these settings may affect the behavior of the system and 

should be done by the system administrator.

NOTE!

 When you define or change the administrator password make sure you save a 

copy of the password in a safe place.

Define the password:

1. 

Navigate to

 Settings > Advanced > Change password

2. 

On the remote control, press the # key to toggle between lower or upper case 

characters and numbers: abc/ABC/123

3. 

Enter the password. The password you enter is hidden, as each character is replaced 

with a star (*).

4. 

Press 

Save

 to save the changes, or Cancel to leave without saving.

5. 

Press 

Home

 

 ) to exit.

Summary of Contents for TANDBERG Quick Set C20

Page 1: ...ra TANDBERG Performance Mic 20 Microphone TANDBERG Remote Control TRCV Accessories 3 HDMI cable for screen and camera connectivity Ethernet cable for LAN VGA to DVI A cable for PC connectivity Camera cable Power supply Camera mounting bracket User Guides The user documentation for TANDBERG products is found on the TANDBERG web site Go to http www tandberg com docs PrecisionHD 1080p 4 PrecisionHD 1...

Page 2: ...ts positioned on top of your monitor to enhance the perceived eye contact PrecisionHD 1080p 12 Camera shown with the lens hood mounted PrecisionHD 1080p 4 Camera requires no lens hood About the PrecisionHD 1080p 12 camera The PrecisionHD 1080p 12 camera comes with a lens hood The use of this lens hood will prevent stray light from disturbing your video experience ...

Page 3: ...lling the TANDBERG Quick Set C20 Caution In order to be able to use the system for video calls all orange colored sockets must be connected Make sure all units are switched off whenever connecting or disconnecting devices Connecting the PrecisionHD 1080p 12 camera ...

Page 4: ...alling the TANDBERG Quick Set C20 Caution In order to be able to use the system for video calls all orange colored sockets must be connected Make sure all units are switched off whenever connecting or disconnecting devices Connecting the PrecisionHD 1080p 4 camera ...

Page 5: ...row key to go back one step 3 Enter the IP Address Subnet Mask and Gateway address in the address fields 4 Press OK to save the changes or Cancel to leave without saving 5 Press Home to exit Verifying IP address settings Go to System Information to verify the IP address 1 Navigate to Settings System Information 2 When the IP address is automatically assigned from a DHCP server the network IP addre...

Page 6: ...pand the items in need of modification and enter the information supplied by your service provider 7 Set the time and date Verify the date and time to see if the time zone settings need to be adjusted The date and time is located in the upper right corner on screen Go to the Time settings to set the date and time 1 Navigate to Settings Date and time If you configure Set date and time to Auto Selec...

Reviews: