Removing the Faceplate
4013399 Rev C
21
To Remove a Faceplate with Feeder Cables Connected (Hot Install)
Follow these steps to remove a faceplate with feeder cables already connected to the
housing.
1
Remove all coax drop cables from the drop port F-connectors.
2
Using a 3/8-in. wrench, loosen all faceplate bolts.
3
If the housing is installed on a strand, go to step 4.
If the housing is installed on a pedestal, go to step 5.
WARNING:
Protect yourself from electric shock and your equipment from damage.
Certain components can deliver an electrical shock.
4
Attach a grounding wire assembly to the strand wire and a drop port F-
connector.
Proceed to step 6.
5
Attach a grounding wire assembly to the strand clamp bolt on the pedestal and a
drop port F-connector.