A-5
Cisco ONS 15600 SDH Reference Manual, Release 9.0
78-18400-01
Appendix A Hardware Specifications
A.2.1 TSC Card Specifications
•
OC48/STM16 LR/LH 16 Port 1550
•
OC48/STM16 SR/SH 16 Port 1310
•
OC192/STM64 LR/LH 4 Port 1550
•
OC192/STM64 SR/SH 4 Port 1310
•
OC192/STM64 4 Port ITU C-BandASAP
•
Filler
A.2.1 TSC Card Specifications
shows the TSC card specifications.
Table A-3
TSC Card Specifications
Specification Type
Description
CTC software
Interface: 10/100BaseT LAN
Backplane (CAP/CAP2) access: RJ-45
TL1 craft interface
Speed: 10/100BaseT LAN
Front panel access: RJ-45 type connector
Backplane access: RJ-45 and EIA/TIA-232 DB-9 type connector
Synchronization
Stratum 3E, per Telcordia GR-1244
Free running access: Accuracy 4.6 ppm
Holdover stability: 3.7 x10
–7
ppm/day including temperature (< 255 slips in
first 24 hours)
Reference: External BITS, line, internal
Operating temperature
23 to 122 degrees Fahrenheit (–5 to +50 degrees Celsius)
Operating humidity
5 to 95 percent, noncondensing
Dimensions
Height: 16.50 in. (419 mm)
Width: 1.10 in. (28 mm)
Depth: 18.31 in. (465 mm)
Card weight: 4.0 lb (1.81 kg)
Compliance
When installed in a node, ONS 15600 SDH cards comply with these safety
standards: UL 60950, CSA C22.2 No. 950, EN 60950, IEC 60950