20-78
Cisco ONS 15454 Procedure Guide, R5.0
March 2005
Chapter 20 DLPs A300 to A399
DLP-A387 Change Line and Threshold Settings for the DS3XM-12 Card
describes the values on the Provisioning > Elect Path Thresholds tabs for the DS3XM-12
cards.
SES
Severely errored seconds
Numeric. Can be set for 15-minute or
one-day intervals. Select the bullet and
click
Show Thresholds
.
LOSS
Loss of signal
Numeric. Can be set for 15-minute or
one-day intervals. Select the bullet and
click
Show Thresholds
.
Table 20-5
Line Thresholds Options for the DS3XM-12 Card (continued)
Parameter
Description
Options
Table 20-6
Electrical Path Threshold Options for the DS3XM-12 Card
Parameter
Description
Options
Port
(Display only.) Port number
1 to 36
CV
Coding violations
Numeric. Can be set for 15-minute or one-day
intervals. Select the bullet and click
Show Thresholds
(DS3, Pbit Near End only; DS3 CPbit, Near and Far
End; DS1, only if there is a VT circuit dropped on the
port).
ES
Errored seconds
Numeric. Can be set for 15-minute or one-day
intervals. Select the bullet and click
Show Thresholds
(DS3, Pbit Near End only; DS3 CPbit, Near and Far
End; DS1, only if there is a VT circuit dropped on the
port).
SES
Severely errored seconds
Numeric. Can be set for 15-minute or one-day
intervals. Select the bullet and click
Show Thresholds
(DS3, Pbit Near End only; DS3 CPbit, Near and Far
End; DS1, only if there is a VT circuit dropped on the
port).
SAS
Severely errored frame/alarm
indication signal
Numeric. Can be set for 15-minute or one-day
intervals. Select the bullet and click
Show Thresholds
(DS3, Pbit Near End only; DS3 CPbit, Near and Far
End; DS1, only if there is a VT circuit dropped on the
port).
AISS
Alarm indication signal
seconds
Numeric. Can be set for 15-minute or one-day
intervals. Select the bullet and click
Show Thresholds
(DS3, Pbit Near End only; DS3 CPbit, Near and Far
End; DS1, only if there is a VT circuit dropped on the
port).
UAS
Unavailable seconds
Numeric. Can be set for 15-minute or one-day
intervals. Select the bullet and click
Show Thresholds
(DS3, Pbit Near End only; DS3 CPbit, Near and Far
End; DS1, only if there is a VT circuit dropped on the
port).
Summary of Contents for ONS 15454 Series
Page 28: ...Tables xxviii Cisco ONS 15454 Procedure Guide R5 0 December 2004 ...
Page 44: ...Tasks xliv Cisco ONS 15454 Procedure Guide R5 0 December 2004 ...
Page 53: ...liii Cisco ONS 15454 Procedure Guide R5 0 December 2004 About this Guide Document Conventions ...
Page 55: ...lv Cisco ONS 15454 Procedure Guide R5 0 December 2004 About this Guide Document Conventions ...
Page 850: ...Index IN 22 Cisco ONS 15454 Procedure Guide R5 0 December 2004 description 4 11 remove 18 23 ...