NTP-A262 Add a Node to a Linear ADM
NTP-A262 Add a Node to a Linear ADM
Note
Optical transmit and receive levels should be in their acceptable range as shown in the specifications
section for each card in
.
Note
In a linear ADM configuration, two OC-N cards in 1+1 protection are connected to two OC-N cards in
1+1 protection on a second node. On the second node, two more OC-N cards are connected to a third
node. The third node can be connected to a fourth node, and so on, depending on the number of nodes
in the linear ADM. Slots 1 to 4 and 14 to 17 or Slots 5 to 6 and 12 to 13 can be used if connections
between nodes are consistent. For example, Slot 5 on the first linear ADM node connects to Slot 5 on
the second linear ADM node for the working path, and Slot 6 connects to Slot 6 for the protect path. The
working OC-N ports have DCC terminations, and the OC-N cards are in a 1+1 protection group.
Step 1
According to local site practice, complete the
“NTP-A108 Back Up the Database” procedure on
for all the nodes in the ring.
Step 2
At the new node, complete one of the following procedures:
•
If the node has not been turned up, complete all procedures in
•
If the node has been turned up, complete the
“NTP-A35 Verify Node Turn-Up” procedure on
.
Step 3
Verify that the new node has two OC-N cards with the same rate as the linear ADM. If the OC-N cards
are not installed, complete the
“NTP-A16 Install the OC-N Cards” procedure on page 2-6
Step 4
Complete
“DLP-A73 Create a 1+1 Protection Group” task on page 17-81
for the two OC-N cards that
will connect to the linear ADM node.
Step 5
Complete the
“DLP-A377 Provision Section DCC Terminations” task on page 20-61
for the working
OC-N card at the new node. Make sure to set the port service state in the Create SDCC Termination
dialog box to
IS
. (Do not create a DCC termination on the protect card.)
Note
DCC failure alarms appear until you create DCC terminations in the linear ADM node and
connect the fiber during
.
Purpose
This procedure adds a single ONS 15454 node to the end of an
ONS 15454 linear add-drop multiplexer (ADM) network. If the linear
ADM carries traffic, you cannot add a node between two linear ADM
nodes using this procedure unless you delete and recreate the circuits.
To avoid deleting and recreating the circuits, use the
Node to a Linear ADM Using the Wizard” procedure on page 14-14
add a node between two linear ADM nodes.
Tools/Equipment
None
Prerequisite Procedures
NTP-A38 Provision a Linear ADM Network, page 5-6
Required/As Needed
As needed
Onsite/Remote
Onsite
Security Level
Provisioning or higher
Summary of Contents for ONS 15454 Series
Page 28: ...Tables xxviii Cisco ONS 15454 Procedure Guide R5 0 December 2004 ...
Page 44: ...Tasks xliv Cisco ONS 15454 Procedure Guide R5 0 December 2004 ...
Page 53: ...liii Cisco ONS 15454 Procedure Guide R5 0 December 2004 About this Guide Document Conventions ...
Page 55: ...lv Cisco ONS 15454 Procedure Guide R5 0 December 2004 About this Guide Document Conventions ...
Page 850: ...Index IN 22 Cisco ONS 15454 Procedure Guide R5 0 December 2004 description 4 11 remove 18 23 ...