![Cisco ONS 15454 DWDM Installation And Operation Manual Download Page 413](http://html.mh-extra.com/html/cisco/ons-15454-dwdm/ons-15454-dwdm_installation-and-operation-manual_63831413.webp)
5-75
Cisco ONS 15454 DWDM Installation and Operations Guide, R6.0
September 2005
Chapter 5 Provision Transponder and Muxponder Cards
DLP-G240 Change MXP_MR_2.5G and MXPP_MR_2.5G Card Line Threshold Settings for SONET or SDH Payloads
Step 1
In node view, double-click the MXP_MR_2.5G or MXPP_MR_2.5G card where you want to change the
line threshold settings.
Step 2
Click the
Provisioning > Line Thresholds > SONET Thresholds
(ANSI) or
SDH Thresholds
(ETSI)
tabs.
Step 3
Modify any of the settings as shown in
.
Note
You must modify Near End, and Far End independently; 15 Min and 1 Day independently; and
Line and Section independently. To do so, choose the appropriate radio button and click
Refresh
.
Table 5-46
MXP_MR_2.5G and MXPP_MR_2.5G Muxponder Card Line Threshold Settings
Field
Description
ONS 15454 Options
ONS 15454 SDH Options
Port
(Display only) Port
number.
•
9 (MXP_MR_2.5G)
•
9 and 10 (MXPP_MR_2.5G)
•
9 (MXP_MR_2.5G)
•
9 and 10 (MXPP_MR_2.5G)
CV
Coding violations.
Numeric. Threshold display options
include:
•
Direction—Near End or Far End
•
Interval—15 Min (minutes) or 1 day
•
Types—Line or Section (near end
only)
Choose an option in each category and
click
Refresh
.
Numeric. Threshold display options
include:
•
Direction—Near End or Far End
•
Interval—15 Min (minutes) or 1 day
•
Types—Multiplex Section or
Regeneration Section (near end only)
Choose an option in each category and
click
Refresh
.
ES
Errored seconds.
Numeric. Threshold display options
include:
•
Direction—Near End or Far End
•
Interval—15 Min (minutes) or 1 day
•
Types—Line or Section (near end
only)
Choose an option in each category and
click
Refresh
.
Numeric. Threshold display options
include:
•
Direction—Near End or Far End
•
Interval—15 Min (minutes) or 1 day
•
Types—Multiplex Section or
Regeneration Section (near end only)
Choose an option in each category and
click
Refresh
.
SES
Severely errored
seconds.
Numeric. Threshold display options
include:
•
Direction—Near End or Far End
•
Interval—15 Min (minutes) or 1 day
•
Types—Line or Section (near end
only)
Choose an option in each category and
click
Refresh
.
Numeric. Threshold display options
include:
•
Direction—Near End or Far End
•
Interval—15 Min (minutes) or 1 day
•
Types—Multiplex Section or
Regeneration Section (near end only)
Choose an option in each category and
click
Refresh
.
Summary of Contents for ONS 15454 DWDM
Page 38: ...Figures xxxviii Cisco ONS 15454 DWDM Installation and Operations Guide R6 0 August 2005 ...
Page 54: ...Procedures liv Cisco ONS 15454 DWDM Installation and Operations Guide R6 0 August 2005 ...
Page 64: ... 64 Cisco ONS 15454 DWDM Installation and Operations Guide R6 0 August 2005 Chapter ...