10-3
Cisco ONS 15327 User Documentation, R3.3
June 2002
Chapter 10 Alarm Monitoring and Management
Viewing ONS 15327 Alarms
10.2.1 Controlling Alarm Display
You can control the display of the alarms on the
Alarms
tab.
shows the actions you can
perform from the
Alarms
tab.
10.2.2 Viewing Alarm-Affected Circuits
User can view which ONS 15327 circuits are affected by a specific alarm. To do this, highlight an alarm
and right-click it. The
Selected Affected Circuits
shortcut menu appears.
illustrates the
Select Affected Circuits option. When the option is clicked, the affected circuits are shown as in
Table 10-2
Color Codes for Alarms, Conditions, and Events
Color
Description
Red
Critical Alarm (CR)
Orange
Major Alarm (MJ)
Yellow
Minor Alarm (MN)
Magenta
Event (NA)
Blue
Condition (NR)
White
Cleared alarm or event (CL)
Table 10-3
Alarm Display
Button
Action
Synchronize Alarms
Updates the alarm display; although CTC displays alarms in real time, the
Synchronize Alarms
button allows you to verify the alarm display. This is
particularly useful during provisioning or troubleshooting.
Delete Cleared Alarms
Deletes alarms that have been cleared.
AutoDelete Cleared
Alarms
If checked, CTC automatically deletes cleared alarms.
Show Events (NA)
If checked, CTC shows alarms and NA events or conditions. Not-alarmed
events do not require action and normally are displayed only under the
Conditions
tab.
Summary of Contents for ONS 15327
Page 22: ...Contents xxii Cisco ONS 15327 User Documentation June 2002 I N D E X ...
Page 30: ...Figures xxviii Cisco ONS 15327 User Documentation June 2002 ...
Page 44: ...Procedures xlii Cisco ONS 15454 Installation and Operations Guide R3 2 June 2002 ...
Page 540: ...Glossary GL 16 Cisco ONS 15327 User Documentation R3 3 June 2002 ...